Yiqing Liang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Yiqing Liang has a total of 20 co-authors. Here are the top co-authors by number of shared publications:
- Rongkun Wang
College of Information Science and Engineering, Huaqiao University, Xiamen 361021, China
4 shared publications - Xinhua Guo
Huaqiao University
3 shared publications - Daqing Gao
Institute of Modern Physics, Chinese Academy of Sciences
2 shared publications - Huajian Zhang
Institute of Modern Physics, Chinese Academy of Sciences
2 shared publications - Minxuan Liao
Department of Electrical Engineering, College of Information Science and Engineering, Huaqiao University, Xiamen, China
2 shared publications - Bin Guo
Huaqiao University
1 shared publication
Latest Publications
- 1 January 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Emerging and Selected Topics in Power Electronics
- p. 1
Robust Dead-Time Harmonic Suppression in PMSM Drives: A Cascaded Resonant Extended State Observer Approach for High-Frequency Peaking Mitigation
- 1 January 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Emerging and Selected Topics in Power Electronics
- p. 1
Robust Dead-Time Harmonic Suppression in PMSM Drives: A Cascaded Resonant Extended State Observer Approach for High-Frequency Peaking Mitigation
- 5 March 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Emerging and Selected Topics in Power Electronics
- Vol. 13 (4) , 5317-5333
A Fault Diagnosis Method for Open-Circuit Fault-Based Voltage Vector Trajectory Distortion Characteristics in Three-Level T-Type Inverters
Three-level T-type inverters are widely used due to their low losses and harmonic distortion. The increased number of switching devices raises failure probability, reducing inverter reliability. Hence, an accurate fault diagnosis method is essential for reliability enhancement. Based on the analysis of voltage vector trajectory under a single-phase single-switch fault in a three-level T-type inverter, voltage vector trajectory distortion characteristics of double-switch open-circuit faults are obtained through vector rotation and combined superposition. Furthermore, the relationship between the voltage vector trajectory distortion characteristics and the locations of open-circuit faults is deduced. Consequently, a diagnosis method is proposed based on the distortion characteristics of voltage vector trajectory. The angle of the distorted voltage vector trajectory is utilized to locate the fault phase, and the average voltage Park vector (AVPV) transformation is employed to obtain two diagnostic features: the normalized mean of phase voltage and the mean error of direct-axis voltage, which enables an accurate location of fault switches. An adaptive threshold is adopted. The method has low complexity and fast speed, with the diagnostic time ranging from 0.05 to 0.55 fundamental cycles. This method can realize the same-phase single-switch and double-switch fault diagnosis, reducing load sensitivity and misdiagnosis.
- 5 March 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Emerging and Selected Topics in Power Electronics
- Vol. 13 (4) , 5317-5333
A Fault Diagnosis Method for Open-Circuit Fault-Based Voltage Vector Trajectory Distortion Characteristics in Three-Level T-Type Inverters
Three-level T-type inverters are widely used due to their low losses and harmonic distortion. The increased number of switching devices raises failure probability, reducing inverter reliability. Hence, an accurate fault diagnosis method is essential for reliability enhancement. Based on the analysis of voltage vector trajectory under a single-phase single-switch fault in a three-level T-type inverter, voltage vector trajectory distortion characteristics of double-switch open-circuit faults are obtained through vector rotation and combined superposition. Furthermore, the relationship between the voltage vector trajectory distortion characteristics and the locations of open-circuit faults is deduced. Consequently, a diagnosis method is proposed based on the distortion characteristics of voltage vector trajectory. The angle of the distorted voltage vector trajectory is utilized to locate the fault phase, and the average voltage Park vector (AVPV) transformation is employed to obtain two diagnostic features: the normalized mean of phase voltage and the mean error of direct-axis voltage, which enables an accurate location of fault switches. An adaptive threshold is adopted. The method has low complexity and fast speed, with the diagnostic time ranging from 0.05 to 0.55 fundamental cycles. This method can realize the same-phase single-switch and double-switch fault diagnosis, reducing load sensitivity and misdiagnosis.
- Open Access
- 8 December 2023
- Published by Association for Computing Machinery (ACM)
- p. 301-305
An Anomaly Detection Model Based on CNN-VAE for IoT Devices
- 8 December 2023
- Published by Association for Computing Machinery (ACM)
- p. 301-305
Open AccessAn Anomaly Detection Model Based on CNN-VAE for IoT Devices
- 29 July 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 71 (00189456) , 1-9
IEEE 1588-Based Timing and Triggering Prototype for Distributed Power Supplies in HIAF
In High-Intensity Heavy Ion Accelerator Facility (HIAF), a high precision timing system is necessary because highly synchronous triggering of distributed power supply (PS) is essential for the facility operation. To obtain a cost-effective local area timing system, a nanosecond-accuracy private synchronization approach based on IEEE 1588 protocol is proposed. Instead of Ethernet protocol usually used, universal asynchronous transceiver protocol over dedicated optical fiber is applied in the method to avoid the uncertain delay in Ethernet architecture. Besides, the timing system simplifies the communication message formats and increases synchronization frequency to 1 kHz to reduce the timing deviation due to oscillator frequency deviation. The test results show that the implementation ensures a synchronization accuracy of better than ±10 ns with 2 ppm temperature-compensation crystal oscillator (TCXO) for dozens of distributed PS controllers.
- 29 July 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 71 (00189456) , 1-9
IEEE 1588-Based Timing and Triggering Prototype for Distributed Power Supplies in HIAF
In High-Intensity Heavy Ion Accelerator Facility (HIAF), a high precision timing system is necessary because highly synchronous triggering of distributed power supply (PS) is essential for the facility operation. To obtain a cost-effective local area timing system, a nanosecond-accuracy private synchronization approach based on IEEE 1588 protocol is proposed. Instead of Ethernet protocol usually used, universal asynchronous transceiver protocol over dedicated optical fiber is applied in the method to avoid the uncertain delay in Ethernet architecture. Besides, the timing system simplifies the communication message formats and increases synchronization frequency to 1 kHz to reduce the timing deviation due to oscillator frequency deviation. The test results show that the implementation ensures a synchronization accuracy of better than ±10 ns with 2 ppm temperature-compensation crystal oscillator (TCXO) for dozens of distributed PS controllers.
- 17 June 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 36 (1) , 911-921
Single-Switch Open-Circuit Diagnosis Method Based on Average Voltage Vector for Three-Level T-Type Inverter
Fault-tolerant control strategy plays a significant role in improving the reliability of three-level T-type inverter where fault diagnosis method is the key and a research hotspot. Load power factor variation and modulation index regulation have great effect on conventional load current based diagnosis methods. Therefore, this paper proposes a novel voltage vector-based method for single-switch open-circuit fault diagnosis in three-level T-type inverter. Average output voltage vector calculated by voltages between dc-link neutral-point and bridge output points is taken as the eigenvector in the method and failed switches can be located by three diagnosis variables including angle of eigenvector, normalized modulus of eigenvector and neutral-point potential. These variables have some certain values after circuit fault, which are defined as eigenvalues. The vector trajectory prediction technology is utilized for threshold setting, by which the method is suitable for different power factors and different modulation indices. The strategy of redundant vector replacement is applied to realize fault-tolerant operation and verifying the proposed method. Simulations and experiments are carried out to illustrate the superiorities of the method.
- 17 June 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 36 (1) , 911-921
Single-Switch Open-Circuit Diagnosis Method Based on Average Voltage Vector for Three-Level T-Type Inverter
Fault-tolerant control strategy plays a significant role in improving the reliability of three-level T-type inverter where fault diagnosis method is the key and a research hotspot. Load power factor variation and modulation index regulation have great effect on conventional load current based diagnosis methods. Therefore, this paper proposes a novel voltage vector-based method for single-switch open-circuit fault diagnosis in three-level T-type inverter. Average output voltage vector calculated by voltages between dc-link neutral-point and bridge output points is taken as the eigenvector in the method and failed switches can be located by three diagnosis variables including angle of eigenvector, normalized modulus of eigenvector and neutral-point potential. These variables have some certain values after circuit fault, which are defined as eigenvalues. The vector trajectory prediction technology is utilized for threshold setting, by which the method is suitable for different power factors and different modulation indices. The strategy of redundant vector replacement is applied to realize fault-tolerant operation and verifying the proposed method. Simulations and experiments are carried out to illustrate the superiorities of the method.