Eduardo López-Pineda
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Eduardo López-Pineda has a total of 20 co-authors. Here are the top co-authors by number of shared publications:
- María Ester Brandan
Universidad Nacional Autónoma de México
5 shared publications C. Ruiz-Trejo
Instituto de Física, Universidad Nacional Autónoma de México, 04511 Ciudad de México, Mexico
2 shared publications- Cesar Ruiz-Trejo
Instituto de Física, Universidad Nacional Autónoma de México, Coyoacán, Ciudad de México 04510, Mexico
2 shared publications I.D. Muñoz
Instituto de Física, Universidad Nacional Autónoma de México, 04511 Ciudad de México, Mexico
2 shared publicationsA. Gómez-Facenda
1 shared publication- Alexis N. Rueda
Facultad de Ciencias, Universidad Nacional Autónoma de México, Coyoacán, Ciudad de México 04510, Mexico
1 shared publication
Latest Publications
- Open Access
- 27 August 2021
- Published by MDPI AG in Applied Sciences
- Vol. 11 (17) , 7930
Dosimetric Evaluation in Micro-CT Studies Used in Preclinical Molecular Imaging
In microCT imaging, there is a close relationship between the dose of radiation absorbed by animals and the image quality, or spatial resolution. Although the radiation levels used in these systems are generally non-lethal, they can induce cellular or molecular alterations that affect the experimental results. Here, we describe a dosimetric characterization of the different image acquisition modalities used by the microCT unit of the Albira microPET/SPECT/CT scanner, which is a widely used multimodal imaging system in preclinical research. The imparted dose at the animal surface (IDS) was estimated based on Boone’s polynomial interpolation method and experimental measurements using an ionization chamber and thermoluminescent dosimeters. The results indicated that the imparted dose at surface level delivered to the mice was in the 30 to 300 mGy range. For any combination of current (0.2 or 0.4 mA) and voltage (35 or 45 kV), in the Standard, Good, and Best image acquisition modalities, the dose imparted at surface level in rodents was below its threshold of deterministic effects (250 mGy); however, the High Res modality was above that threshold.
- 27 August 2021
- Published by MDPI AG in Applied Sciences
- Vol. 11 (17) , 7930
Open AccessDosimetric Evaluation in Micro-CT Studies Used in Preclinical Molecular Imaging
In microCT imaging, there is a close relationship between the dose of radiation absorbed by animals and the image quality, or spatial resolution. Although the radiation levels used in these systems are generally non-lethal, they can induce cellular or molecular alterations that affect the experimental results. Here, we describe a dosimetric characterization of the different image acquisition modalities used by the microCT unit of the Albira microPET/SPECT/CT scanner, which is a widely used multimodal imaging system in preclinical research. The imparted dose at the animal surface (IDS) was estimated based on Boone’s polynomial interpolation method and experimental measurements using an ionization chamber and thermoluminescent dosimeters. The results indicated that the imparted dose at surface level delivered to the mice was in the 30 to 300 mGy range. For any combination of current (0.2 or 0.4 mA) and voltage (35 or 45 kV), in the Standard, Good, and Best image acquisition modalities, the dose imparted at surface level in rodents was below its threshold of deterministic effects (250 mGy); however, the High Res modality was above that threshold.
- 13 July 2020
- Published by IOP Publishing in Journal of Physics D: Applied Physics
- Vol. 53 (40) , 405302
The isotropic emission of tribo-generated x-rays from peeling adhesive tape
X-rays generated through tribological processes are emitted in fast bursts (∼10 ns) that hinder the correct measurement of the corresponding spectrum. In this work we implement a dosimetry technique based on thermoluminescent materials—impervious to pileup problems arising in solid-state active detectors—to measure the angular distribution of the tribo-generated x-rays from peeling adhesive tape. Unexpectedly, we find evidence of an isotropic energy emission on at least one meridian plane. These results may shed light on the physical processes behind the radiation emission in devices that harness the triboelectric effect to generate x-rays, and prove that dosimetry techniques can be used as an alternative characterization tool in the study of the emission from this and other relatively fast systems.
- 13 July 2020
- Published by IOP Publishing in Journal of Physics D: Applied Physics
- Vol. 53 (40) , 405302
The isotropic emission of tribo-generated x-rays from peeling adhesive tape
X-rays generated through tribological processes are emitted in fast bursts (∼10 ns) that hinder the correct measurement of the corresponding spectrum. In this work we implement a dosimetry technique based on thermoluminescent materials—impervious to pileup problems arising in solid-state active detectors—to measure the angular distribution of the tribo-generated x-rays from peeling adhesive tape. Unexpectedly, we find evidence of an isotropic energy emission on at least one meridian plane. These results may shed light on the physical processes behind the radiation emission in devices that harness the triboelectric effect to generate x-rays, and prove that dosimetry techniques can be used as an alternative characterization tool in the study of the emission from this and other relatively fast systems.
- Open Access
- 10 April 2019
- Published by AIP Publishing in AIP Conference Proceedings
- Vol. 2090 (1) , 030007
Dependence of the TLD-300 glow curve on the photon field direction of incidence. Studies in air and in phantom for mammography and CT x-rays
The glow curve of the CaF2:Tm thermoluminescent dosimeter (TLD-300) has the remarkable property of showing sensitivity to the energy of the radiation field. Careful analyses of the TLD-300 glow curve enable to determine the effective energy of the incident low- and intermediate-energy X ray photons, with a typical accuracy of 1 keV. The effect is consequence of different efficiencies for the high- and low-temperature peaks as a function of the secondary spectrum ionization density. Since the TLD-300 dosimeters have parallelepiped shape (3.2 × 3.2 × 0.89 mm3) and the spectra incident on its different sides do suffer a distinctive spectral hardening as they traverse the dosimeter, we have investigated the dependence of the emitted light and the glow curve shape on the beam direction of incidence with respect to the dosimeter geometrical shape. We have exposed dosimeters to photon spectra with effective energies between 15 and 60 keV (mammography and computed tomography, CT, beams) and studied the integrated TL response and the glow curve, for irradiations in air (essentially uni-directional) and inside phantoms (with an important multi-directional component from scattered radiation). Two limit cases were investigated: beam incidence on the main face (3.2 × 3.2 mm2) and incidence on a side face (3.2 × 0.89 mm2). A rigorous glow curve deconvolution process was applied to obtain 7 peaks, following our laboratory protocol. The observations with CT beams were interpreted by Monte Carlo simulations. Results showed that for irradiation in air, the ratio of integrated thermoluminescent response after side- and main-face exposures was about 0.3 at mammography energies (15 - 17 keV effective energy) and about 0.8 at CT energies (45 - 58 keV effective energy). These ratios became 0.6 - 0.7 and 0.9 - 1.0, respectively, inside plastic phantoms appropriate for each clinical modality. The glow curve analysis showed that, both for mammography and CT energies inside a phantom, there is no statistically significant difference between the effective energies obtained after main- and side-face exposures. We have concluded that exposure of TLD-300 inside phantoms can determine the radiation field effective energy for beams which are similar to those in this study, independent of the dosimeter orientation with respect to the primary beam.
- 10 April 2019
- Published by AIP Publishing in AIP Conference Proceedings
- Vol. 2090 (1) , 030007
Open AccessDependence of the TLD-300 glow curve on the photon field direction of incidence. Studies in air and in phantom for mammography and CT x-rays
The glow curve of the CaF2:Tm thermoluminescent dosimeter (TLD-300) has the remarkable property of showing sensitivity to the energy of the radiation field. Careful analyses of the TLD-300 glow curve enable to determine the effective energy of the incident low- and intermediate-energy X ray photons, with a typical accuracy of 1 keV. The effect is consequence of different efficiencies for the high- and low-temperature peaks as a function of the secondary spectrum ionization density. Since the TLD-300 dosimeters have parallelepiped shape (3.2 × 3.2 × 0.89 mm3) and the spectra incident on its different sides do suffer a distinctive spectral hardening as they traverse the dosimeter, we have investigated the dependence of the emitted light and the glow curve shape on the beam direction of incidence with respect to the dosimeter geometrical shape. We have exposed dosimeters to photon spectra with effective energies between 15 and 60 keV (mammography and computed tomography, CT, beams) and studied the integrated TL response and the glow curve, for irradiations in air (essentially uni-directional) and inside phantoms (with an important multi-directional component from scattered radiation). Two limit cases were investigated: beam incidence on the main face (3.2 × 3.2 mm2) and incidence on a side face (3.2 × 0.89 mm2). A rigorous glow curve deconvolution process was applied to obtain 7 peaks, following our laboratory protocol. The observations with CT beams were interpreted by Monte Carlo simulations. Results showed that for irradiation in air, the ratio of integrated thermoluminescent response after side- and main-face exposures was about 0.3 at mammography energies (15 - 17 keV effective energy) and about 0.8 at CT energies (45 - 58 keV effective energy). These ratios became 0.6 - 0.7 and 0.9 - 1.0, respectively, inside plastic phantoms appropriate for each clinical modality. The glow curve analysis showed that, both for mammography and CT energies inside a phantom, there is no statistically significant difference between the effective energies obtained after main- and side-face exposures. We have concluded that exposure of TLD-300 inside phantoms can determine the radiation field effective energy for beams which are similar to those in this study, independent of the dosimeter orientation with respect to the primary beam.
- 1 January 2019
- Published by AIP Publishing in AIP Conference Proceedings
- Vol. 2099, 030004
Generation of a mammographic phantom using an inkjet printer and radiopaque ink
- 1 January 2019
- Published by AIP Publishing in AIP Conference Proceedings
- Vol. 2099, 030004
Generation of a mammographic phantom using an inkjet printer and radiopaque ink
- 1 November 2017
- Published by Elsevier in Radiation Measurements
- Vol. 106, 341-345
Dual TLD-100/TLD-300 method to evaluate beam quality and absorbed dose in radiological imaging procedures
- 1 November 2017
- Published by Elsevier in Radiation Measurements
- Vol. 106, 341-345
Dual TLD-100/TLD-300 method to evaluate beam quality and absorbed dose in radiological imaging procedures
- 1 January 2016
- Published by AIP Publishing in AIP Conference Proceedings
- Vol. 1747 (1) , 080004
Image quality and mean glandular dose in Mexican mammography services measured with an Object-Insert/TL mammography kit
Thirty mammography systems were evaluated using an Object-Insert/TL kit (composed of an image quality and a dosimetric phantom) to assess image quality and mean glandular dose. All systems complied with the minimum score for object visibility in the image phantom, but most of the images showed artifacts. The average of the mean glandular dose was 1.7±0.7 mGy, and three systems delivered doses higher than the 3 mGy reference value. A weak correlation was found between image quality and dose, possibly reflecting the lack of quality control in the evaluated equipment.
- 1 January 2016
- Published by AIP Publishing in AIP Conference Proceedings
- Vol. 1747 (1) , 080004
Image quality and mean glandular dose in Mexican mammography services measured with an Object-Insert/TL mammography kit
Thirty mammography systems were evaluated using an Object-Insert/TL kit (composed of an image quality and a dosimetric phantom) to assess image quality and mean glandular dose. All systems complied with the minimum score for object visibility in the image phantom, but most of the images showed artifacts. The average of the mean glandular dose was 1.7±0.7 mGy, and three systems delivered doses higher than the 3 mGy reference value. A weak correlation was found between image quality and dose, possibly reflecting the lack of quality control in the evaluated equipment.
- 1 December 2014
- Published by Elsevier in Radiation Measurements
- Vol. 71, 297-299
A mammographic phantom to measure mean glandular dose by thermoluminescent dosimetry
- 1 December 2014
- Published by Elsevier in Radiation Measurements
- Vol. 71, 297-299
A mammographic phantom to measure mean glandular dose by thermoluminescent dosimetry