Alexis N. Rueda
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Alexis N. Rueda has a total of 4 co-authors. Here are the top co-authors by number of shared publications:
- Cesar Ruiz-Trejo
Instituto de Física, Universidad Nacional Autónoma de México, Coyoacán, Ciudad de México 04510, Mexico
1 shared publication - Eduardo López-Pineda
Instituto de Física, Universidad Nacional Autónoma de México, Coyoacán, Ciudad de México 04510, Mexico
1 shared publication - Luis Alberto Medina
Unidad de Investigación Biomédica en Cáncer INCan-UNAM, Instituto Nacional de Cancerología, Cd. México 14080, Mexico
1 shared publication - Mario E. Romero-Piña
Unidad de Investigación Biomédica en Cáncer, INCan/UNAM, Instituto Nacional de Cancerología, Tlalpan, Ciudad de México 14080, Mexico
1 shared publication
Latest Publications
- Open Access
- 27 August 2021
- Published by MDPI AG in Applied Sciences
- Vol. 11 (17) , 7930
Dosimetric Evaluation in Micro-CT Studies Used in Preclinical Molecular Imaging
In microCT imaging, there is a close relationship between the dose of radiation absorbed by animals and the image quality, or spatial resolution. Although the radiation levels used in these systems are generally non-lethal, they can induce cellular or molecular alterations that affect the experimental results. Here, we describe a dosimetric characterization of the different image acquisition modalities used by the microCT unit of the Albira microPET/SPECT/CT scanner, which is a widely used multimodal imaging system in preclinical research. The imparted dose at the animal surface (IDS) was estimated based on Boone’s polynomial interpolation method and experimental measurements using an ionization chamber and thermoluminescent dosimeters. The results indicated that the imparted dose at surface level delivered to the mice was in the 30 to 300 mGy range. For any combination of current (0.2 or 0.4 mA) and voltage (35 or 45 kV), in the Standard, Good, and Best image acquisition modalities, the dose imparted at surface level in rodents was below its threshold of deterministic effects (250 mGy); however, the High Res modality was above that threshold.
- 27 August 2021
- Published by MDPI AG in Applied Sciences
- Vol. 11 (17) , 7930
Open AccessDosimetric Evaluation in Micro-CT Studies Used in Preclinical Molecular Imaging
In microCT imaging, there is a close relationship between the dose of radiation absorbed by animals and the image quality, or spatial resolution. Although the radiation levels used in these systems are generally non-lethal, they can induce cellular or molecular alterations that affect the experimental results. Here, we describe a dosimetric characterization of the different image acquisition modalities used by the microCT unit of the Albira microPET/SPECT/CT scanner, which is a widely used multimodal imaging system in preclinical research. The imparted dose at the animal surface (IDS) was estimated based on Boone’s polynomial interpolation method and experimental measurements using an ionization chamber and thermoluminescent dosimeters. The results indicated that the imparted dose at surface level delivered to the mice was in the 30 to 300 mGy range. For any combination of current (0.2 or 0.4 mA) and voltage (35 or 45 kV), in the Standard, Good, and Best image acquisition modalities, the dose imparted at surface level in rodents was below its threshold of deterministic effects (250 mGy); however, the High Res modality was above that threshold.