JMJoseph E. Minor

Joseph E. Minor

*This is an algorithmically generated author record based on publicly available information.

Joseph E. Minor has a total of 4 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Insulating Glass Unit Quick Selection Guide

    by Joseph E. Minor, H. Scott Norville

    The structural design of sealed insulating glass units for wind loads involves complex structural mechanics procedures that address load sharing between two glass lites that vary in thickness, dimensions, and heat treatments. In exhaustive studies of windows in mid- and high-rise buildings, it has been shown that any one of six commonly used window glass lites [6, 8, 10 mm (1/4, 5/16, 3/8 in.), heat-strengthened and fully tempered], acting alone, can represent the minimum load resistance of dual-lite, sealed insulating glass units that contain this lite when paired with any one of the six listed lites. Further, the minimum load resistance of each of these six lites can be related to building height by employing wind load design of current standards. An innovative technique permits selection of dual-lite insulating glass unit constructions for mid- and high-rise buildings in the Inland Zone and a Hurricane Zone that meet wind load provisions of building codes based upon building height alone, without calculations.

  • Selection of Architectural Glazing Constructions without Calculations

    by Joseph E. Minor, H. Scott Norville

    A single table permits the designer of architectural glazing systems to select glazing constructions that will meet specified design wind loads. This simplification of the glazing construction selection process employs, as working elements, the minimum load resistance of commonly used glass thicknesses and opening areas. The process is based on two principal observations: (1) heat-treated lites (heat strengthened and fully tempered) with relatively large areas of approximately 4.6–6.5 m2 (50–70 ft2) can carry relatively large design pressures in excess of 4.8 kPa (100 psf) acting alone, thus eliminating the need for load-sharing analysis in most common sizes of insulating glass units; and (2) the load resistances of commonly used monolithic and polyvinylbutyral-laminated lites with identical dimensions and designated thickness are close enough to be considered equal, within 140 Pa (3 psf).


  • A Simple Table for Selecting Insulating Glass Unit Constructions

    by Joseph E. Minor

    The selection of an insulating glass unit construction for a specified design wind load, based upon provisions of ASTM Standard E1300-16, has been reduced to one simple table. This simplification is based upon three principal observations: (1) most commercial IG unit constructions are dual pane units comprised of combinations of but three lite thicknesses, (2) the strengths of single monolithic lites and laminated lites with these three lites thicknesses are nearly the same, and (3) IG units containing relatively large, fully tempered glass lites with the largest of these three thicknesses can carry wind loads exceeding most design wind load requirements. The basis for and formulation of the single table for selection of IG unit construction for a specified design wind load are presented.

  • Design of Window Glass for Lateral Pressures

    by Joseph E. Minor, H. Scott Norville

    ASTM Standard E 1300-04 (“Standard practice for determining load resistance of glass in buildings”) outlines procedures for determining the strength of window glass products when the glass is subjected to uniform lateral pressure. This standard practice addresses each of the commonly used window glass products (monolithic glass, laminated glass, and insulating glass) that are fabricated from annealed, heat strengthened, and fully tempered glass plates, used singly or in combination. The procedures are based on principles of structural mechanics, are thorough, and are presented in clear and concise terms. Analyses of the basis for and the scope of these procedures lead to two interesting observations. First, the procedures are based on a very conservative definition of glass strength, and, second, the procedures encompass certain technical refinements, design conditions, and product configurations that are outside of practical application, thus making the procedures appear overly complex to the user. Recommendations are offered for taking advantage of the inherent conservatism and discerning perspectives to make the procedures simpler and more practical.


  • Lessons Learned from Failures of the Building Envelope in Windstorms

    by Joseph E. Minor

    Lessons learned from failures of the building envelope in windstorms are encapsulated in three principal findings. The building envelope is crucial to the performance of buildings in windstorms. Windborne debris is decisive in shaping the performance of the building envelope. Design attention should be given to postimpact behavior of building-envelope systems. Reviews of damage documentation, insurance records, and computer simulations of building failures establish the importance of the building envelope to satisfactory building performance. These reviews also establish the decisive role of windborne debris in causing damage. The imperative for considering the postimpact behavior of building envelope systems is discussed, and innovative glazing products that meet new design criteria are presented. It is concluded that the building envelope should be given status equal to the principal structural frame in terms of design attention.


  • Simplified Window Glass Design Procedure

    by H. Scott Norville, Joseph E. Minor

    This paper presents a simplified window glass design procedure (SWGDP) as an alternative to the comprehensive window glass design procedure described in ASTM E 1300, “Standard practice for determining the load resistance of glass in buildings.” Although ASTM E 1300 provides a technically robust treatment of the strength of window glass and window glass constructions, architects and engineers will find ASTM E 1300 difficult to use. The SWGDP presented herein uses the same failure prediction methodology to characterize the annealed window glass strength that underlies ASTM E 1300. By reducing the number of basic glass strength charts to one, the voluminous strength adjustment factors in ASTM E 1300 to one simple table, and the computation of window glass lite center deflections to simple graphs requiring no computations to use, the SWGDP achieves simplicity in its approach to window glass design.


  • Postbreakage Behavior of Heat Strengthened Laminated Glass under Wind Effects

    by Chris P. Pantelides, Amy D. Horst, Joseph E. Minor

    Results of a full‐scale experimental investigation into the postbreakage behavior of heat‐strengthened laminated glass subjected to windstorm effects are presented. Two different interlayer constructions and two different glazing configurations are examined. The two interlayer constructions are a PVB polymer and a PVB/PET/PBV composite polymer. The two glazing configurations are a conventional dry glazed system and an unconventional system with a silicone anchor bead. Two test criteria are established that relate to effects of a severe windstorm. The first criterion addresses impact with windborne debris; the second defines a wind‐load spectrum that represents a severe windstorm of a 4‐hr duration. Three principal findings are presented. First, the ability of heat strengthened laminated glass to reject small missile impacts with small probabilities of breaking the inner glass ply is established. Second, heat‐strengthened laminated glass with the silicone anchor bead performed significantly better than sim...