John G. Georgiadis
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
John G. Georgiadis has a total of 10 co-authors. Here are the top co-authors by number of shared publications:
- Aristides M. Bonanos
Energy, Environment and Water Center, The Cyprus Institute, Nicosia, Cyprus
2 shared publications - Bradley P. Sutton
University of Illinois Urbana-Champaign
2 shared publications - Marios D. Georgiou
Department of Mechanical Science and Engineering, University of Illinois at Urbana-Champaign, Urbana, IL 61801
2 shared publications - Curtis L. Johnson
Department of Mechanical Science and Engineering, University of Illinois at Urbana-Champaign, Urbana, IL 61801, USA
1 shared publication - Dimitrios C. Karampinos
Institute of Diagnostic and Interventional Radiology, School of Medicine and Health, Technical University of Munich, Munich, Germany
1 shared publication Elijah E. W. Van Houten
Département de génie mécanique Université de Sherbrooke Sherbrooke Québec Canada
1 shared publication
Latest Publications
- 20 September 2016
- Published by Wiley in Journal of Heat Transfer
- Vol. 139 (1) , 012503
Experimental Investigation of Transitional Natural Convection in a Cube Using Particle Image Velocimetry—Part II: Turbulence Quantities and Proper Orthogonal Decomposition
An experimental investigation of transitional natural convection in an air filled cube was conducted in this research. The characteristic dimension of the enclosure was H = 0.35 m, and data were collected in the middle plane of the cavity. The Rayleigh number range examined was 5.0×107≤Ra≤3.4×108. In Part I, the authors presented the mean velocity profiles in the enclosure and conducted heat transfer measurements on the hot wall. An expression between Nu and Ra numbers was concluded and compared against other correlations available in literature. In the present work, the authors present a complete description of the flow in the enclosure by quantifying the low turbulence regime developed in the cavity. This was accomplished by estimating Reynolds stresses, turbulent kinetic energy, vorticity, and swirling strength. Proper orthogonal decomposition (POD) was employed to analyze the flow fields obtained from the experimental data and retain the most salient features of the flow field. This study attempts to close the gap of available experimental data in the literature and provide experimental benchmark data that can be used to validate CFD codes since the estimated error from particle image velocimetry (PIV) measurements is within 1–2%.
- 20 September 2016
- Published by Wiley in Journal of Heat Transfer
- Vol. 139 (1) , 012503
Experimental Investigation of Transitional Natural Convection in a Cube Using Particle Image Velocimetry—Part II: Turbulence Quantities and Proper Orthogonal Decomposition
An experimental investigation of transitional natural convection in an air filled cube was conducted in this research. The characteristic dimension of the enclosure was H = 0.35 m, and data were collected in the middle plane of the cavity. The Rayleigh number range examined was 5.0×107≤Ra≤3.4×108. In Part I, the authors presented the mean velocity profiles in the enclosure and conducted heat transfer measurements on the hot wall. An expression between Nu and Ra numbers was concluded and compared against other correlations available in literature. In the present work, the authors present a complete description of the flow in the enclosure by quantifying the low turbulence regime developed in the cavity. This was accomplished by estimating Reynolds stresses, turbulent kinetic energy, vorticity, and swirling strength. Proper orthogonal decomposition (POD) was employed to analyze the flow fields obtained from the experimental data and retain the most salient features of the flow field. This study attempts to close the gap of available experimental data in the literature and provide experimental benchmark data that can be used to validate CFD codes since the estimated error from particle image velocimetry (PIV) measurements is within 1–2%.
- 20 September 2016
- Published by Wiley in Journal of Heat Transfer
- Vol. 139 (1) , 012502
Experimental Investigation of Transitional Natural Convection in a Cube Using Particle Image Velocimetry—Part I: Fluid Flow and Thermal Fields
An experimental investigation of transitional natural convection in an air filled cube was conducted in this research. The characteristic dimension of the enclosure is 0.35 m, and data were collected in the middle plane of the cavity. The Rayleigh number range examined is 5.0×107≤Ra≤3.4×108. This was achieved by varying the temperature on the hot and cold walls. The velocity field in the middle plane is measured using particle image velocimetry (PIV). Temperature measurements in the core of the enclosure indicate a linear profile. The average Nu number is also presented and compared against other correlations in the literature. This study attempts to close the gap of available experimental data in literature and provide experimental benchmark data that can be used to validate computational fluid dynamics (CFD) codes since the estimated error from PIV measurements is within 1–2%.
- 20 September 2016
- Published by Wiley in Journal of Heat Transfer
- Vol. 139 (1) , 012502
Experimental Investigation of Transitional Natural Convection in a Cube Using Particle Image Velocimetry—Part I: Fluid Flow and Thermal Fields
An experimental investigation of transitional natural convection in an air filled cube was conducted in this research. The characteristic dimension of the enclosure is 0.35 m, and data were collected in the middle plane of the cavity. The Rayleigh number range examined is 5.0×107≤Ra≤3.4×108. This was achieved by varying the temperature on the hot and cold walls. The velocity field in the middle plane is measured using particle image velocimetry (PIV). Temperature measurements in the core of the enclosure indicate a linear profile. The average Nu number is also presented and compared against other correlations in the literature. This study attempts to close the gap of available experimental data in literature and provide experimental benchmark data that can be used to validate computational fluid dynamics (CFD) codes since the estimated error from PIV measurements is within 1–2%.
- Open Access
- 21 September 2012
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 70 (2) , 404-412
Magnetic resonance elastography of the brain using multishot spiral readouts with self‐navigated motion correction
Magnetic resonance elastography (MRE) has been introduced in clinical practice as a possible surrogate for mechanical palpation, but its application to study the human brain in vivo has been limited by low spatial resolution and the complexity of the inverse problem associated with biomechanical property estimation. Here, we report significant improvements in brain MRE data acquisition by reporting images with high spatial resolution and signal‐to‐noise ratio as quantified by octahedral shear strain metrics. Specifically, we have developed a sequence for brain MRE based on multishot, variable‐density spiral imaging, and three‐dimensional displacement acquisition and implemented a correction scheme for any resulting phase errors. A Rayleigh damped model of brain tissue mechanics was adopted to represent the parenchyma and was integrated via a finite element‐based iterative inversion algorithm. A multiresolution phantom study demonstrates the need for obtaining high‐resolution MRE data when estimating focal mechanical properties. Measurements on three healthy volunteers demonstrate satisfactory resolution of gray and white matter, and mechanical heterogeneities correspond well with white matter histoarchitecture. Together, these advances enable MRE scans that result in high‐fidelity, spatially resolved estimates of in vivo brain tissue mechanical properties, improving upon lower resolution MRE brain studies that only report volume averaged stiffness values. Magn Reson Med 70:404–412, 2013.
- 21 September 2012
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 70 (2) , 404-412
Open AccessMagnetic resonance elastography of the brain using multishot spiral readouts with self‐navigated motion correction
Magnetic resonance elastography (MRE) has been introduced in clinical practice as a possible surrogate for mechanical palpation, but its application to study the human brain in vivo has been limited by low spatial resolution and the complexity of the inverse problem associated with biomechanical property estimation. Here, we report significant improvements in brain MRE data acquisition by reporting images with high spatial resolution and signal‐to‐noise ratio as quantified by octahedral shear strain metrics. Specifically, we have developed a sequence for brain MRE based on multishot, variable‐density spiral imaging, and three‐dimensional displacement acquisition and implemented a correction scheme for any resulting phase errors. A Rayleigh damped model of brain tissue mechanics was adopted to represent the parenchyma and was integrated via a finite element‐based iterative inversion algorithm. A multiresolution phantom study demonstrates the need for obtaining high‐resolution MRE data when estimating focal mechanical properties. Measurements on three healthy volunteers demonstrate satisfactory resolution of gray and white matter, and mechanical heterogeneities correspond well with white matter histoarchitecture. Together, these advances enable MRE scans that result in high‐fidelity, spatially resolved estimates of in vivo brain tissue mechanical properties, improving upon lower resolution MRE brain studies that only report volume averaged stiffness values. Magn Reson Med 70:404–412, 2013.
- 11 September 2009
- Published by Springer Nature in Annals of Biomedical Engineering
- Vol. 37 (12) , 2532-2546
Myofiber Ellipticity as an Explanation for Transverse Asymmetry of Skeletal Muscle Diffusion MRI In Vivo Signal
Due to its unique non-invasive microstructure probing capabilities, diffusion tensor imaging (DTI) constitutes a valuable tool in the study of fiber orientation in skeletal muscles. By implementing a DTI sequence with judiciously chosen directional encoding to quantify in vivo the microarchitectural properties in the calf muscles of three healthy volunteers at rest, we report that the secondary eigenvalue is significantly higher than the tertiary eigenvalue, a phenomenon corroborated by prior DTI findings. Toward a physics-based explanation of this phenomenon, we propose a composite medium model that accounts for water diffusion in the space within the muscle fiber and the extracellular space. The muscle fibers are abstracted as cylinders of infinite length with an elliptical cross section, the latter closely approximating microstructural features well documented in prior histological studies of excised muscle. The range of values of fiber ellipticity predicted by our model agrees with these studies, and the spatial orientation of the cross-sectional ellipses is consistent with local muscle strain fields and the putative direction of lateral transmission of stress between fibers in certain regions in three antigravity muscles (Tibialis Anterior, Soleus, and Gastrocnemius), as well as independent measurements of deformation in active calf muscles. As a metric, fiber cross-sectional ellipticity may be useful for quantifying morphological changes in skeletal muscle fibers with aging, hypertrophy, or sarcopenia.
- 11 September 2009
- Published by Springer Nature in Annals of Biomedical Engineering
- Vol. 37 (12) , 2532-2546
Myofiber Ellipticity as an Explanation for Transverse Asymmetry of Skeletal Muscle Diffusion MRI In Vivo Signal
Due to its unique non-invasive microstructure probing capabilities, diffusion tensor imaging (DTI) constitutes a valuable tool in the study of fiber orientation in skeletal muscles. By implementing a DTI sequence with judiciously chosen directional encoding to quantify in vivo the microarchitectural properties in the calf muscles of three healthy volunteers at rest, we report that the secondary eigenvalue is significantly higher than the tertiary eigenvalue, a phenomenon corroborated by prior DTI findings. Toward a physics-based explanation of this phenomenon, we propose a composite medium model that accounts for water diffusion in the space within the muscle fiber and the extracellular space. The muscle fibers are abstracted as cylinders of infinite length with an elliptical cross section, the latter closely approximating microstructural features well documented in prior histological studies of excised muscle. The range of values of fiber ellipticity predicted by our model agrees with these studies, and the spatial orientation of the cross-sectional ellipses is consistent with local muscle strain fields and the putative direction of lateral transmission of stress between fibers in certain regions in three antigravity muscles (Tibialis Anterior, Soleus, and Gastrocnemius), as well as independent measurements of deformation in active calf muscles. As a metric, fiber cross-sectional ellipticity may be useful for quantifying morphological changes in skeletal muscle fibers with aging, hypertrophy, or sarcopenia.