UCUmberto Cesaro

Umberto Cesaro

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Umberto Cesaro has a total of 10 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • A Prototype to Measure Water Content in Pyroclastic Soil Covers

    by Simona Guglielmi, Marianna Pirone, Nicola Amatucci, Umberto Cesaro, Mauro D’aRco, Gianfranco Urciuoli

  • Insulin Meter

    by P. Arpaia, U. Cesaro, N. Moccaldi, I. Sannino

    The concept, the whole system design, along with the hardware and software realization of an on-chip transducer, for real-time noninvasive monitoring of insulin absorption, namely the Insulin Meter, are described in the fifth chapter.

  • Non-Invasive Monitoring of Transdermal Drug Delivery

    by P. Arpaia, U. Cesaro, N. Moccaldi, I. Sannino

    The book presents an innovative technology based on injection of a very weak current to trace the quantity of a drug carried immediately after the administration. The book makes the reader familiar with the technology, from the conception through the design of the instrument, up to the preliminary clinical applications. In the first chapter, the method of transdermal drug delivery and the use of impedance spectroscopy in the dermatological field are presented. The second chapter describes a screening measurement campaign aimed at proving the feasibility of the assessment method and identifying the bandwidth of interest. The prototyping, validation and characterization of an instrument to measure the amount of drug delivered (DUSM: Drug Under Skin Meter) are presented in chapter three. In the fourth chapter three experimental campaigns, based on the electrical analysis of the biological tissue behavior due to the drug delivery, are reported: (i) laboratory emulation on eggplants, (ii) ex-vivo tests on pig ears, and finally (iii) in-vivo tests on human volunteers. In the fifth chapter a behavioral model, based on Finite Elements and Partial Differential Equation, of an impedance-based measurement system for assessing the drug released under the skin, during transdermal delivering, is proposed. The last chapter is dedicated to present a campaign in order to prove the suitability for insulin therapy applications. This book is intended for biomedical engineers, biomedical engineering students, operators working in the field of biomedical instrumentation, biotechnologists, and technicians of transdermal vehiculation.

  • An Ultrasonic Heading Goniometer Intrinsically Robust to Magnetic Interference

    by Pasquale Arpaia, Umberto Cesaro, Daniele Gatti, Nicola Moccaldi

    An ultrasonic heading measurement method, working under magnetic interference prohibitive for magnetometers, was prototyped, validated, and metrologically characterized. Two capacitive ultrasonic transducers convert the mechanical rotation in two correspondingly time-delayed electrical sine waves. Then, the time delay is estimated using the standard tree parameter sine-fitting algorithm. The prototyped goniometer achieves the same repeatability level (< 36 mrad) of a magnetometer-based heading in the range [-437 mrad, 437 mrad]. Simultaneously, a throughput of 505 Sa/s is proved on an STM32F303xC Arm® Cortex® -M4 32-bit micro-controller. An interference analysis revealed the experimental deterministic error well explained by the combined effect of beacon and receiver directivity, as well as by the relative position of beacon, receiver, and reflective surfaces. Noise robustness was assessed in case of SNR decayed to 9.1 dB from the initial value of 36.6 dB: the maximum deterministic error in the range [-437 mrad, 437 mrad] increased less than 10% (from 21 mrad to 23 mrad in absolute value).