NSNenad Stepanic

Nenad Stepanic

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Nenad Stepanic has a total of 11 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Experimental study of PCM effects on indoor temperature in lightweight buildings

    by Dragoslav Mrdja, Biljana Vucicevic, Valentina Turanjanin, Nenad Stepanic, Milica Mladenovic, Predrag Skobalj, Milan Gojak

    Phase change materials (PCMs) integrated into lightweight building envelopes were experimentally evaluated to assess their impact on indoor thermal performance. A PCM test house and a reference test house were examined under two conditions: without ventilation and with night ventilation. The experiments were conducted under the climatic conditions of the Republic of Serbia, in Belgrade, at the Vinca Institute of Nuclear Sciences. Two observation periods were defined to evaluate the thermal behaviour of the test houses, with four thermal cycles monitored in each period. Results indicate that, on hot sunny days, the PCM test house achieved maximal indoor air temperature reduction of 3.5-4.8 ?C during the non-ventilated period and 4.2-5.9 ?C during the night-ventilated period, while reducing thermal load levelling (TLL) by 64.1-72.5% and 45.5-49.5%, respectively. The average indoor temperature reduction (AITR) ranged from 0.03-6.12% in the first period and from 3.19-6.54% in the second, confirming the potential of passive PCM application for improving indoor thermal stability. These findings show the practical benefits of PCMs in enhancing energy efficiency and indoor thermal comfort in lightweight buildings.

  • Open Access

    Development of a single-sided guarded hot plate apparatus for thermal conductivity measurements

    by Marijana M. Terzić, Nenad D. Milošević, Nenad M. Stepanić, Slobodan J. Petričević

    This work presents the development of an experimental setup for measurements on of thermal conductivity of solid materials, such as ceramics, polymers, rubbers, glasses, biological materials, etc. whose thermal conductivity lies in the approximate range between 0.1 and 2 Wm-1K-1. The setup was designed on the principle of the single-sided guarded hot plate method. In order to find the optimal design for generation of traceable one-dimensional heat flux through an investigated 300?300 mm2 specimen, a numerical heat transfer FEM analysis was performed. The principal components of the measuring apparatus, such as hot plate with thermopile, cold plate and auxiliary hot plate were constructed according to the obtained results of simulations. Software for the control of experiment and data acquisition was developed using the LabVIEW programming environment.


  • Open Access

    Software solution for control and data acquisition in the pulse calorimetry method

    by Marijana Babic, Nenad Milosevic, Nenad Stepanic

    This work presents a software solution for adjusting, controlling, displaying, and acquiring parameters and data in the pulse calorimetry experimental technique for specific heat capacity, electrical resistivity, total hemispherical emissivity, and normal spectral emissivity measurements. The software has been developed under the LabVIEW platform, V.7.11, and an example of its application with measurement results is presented in a separate section. The total expanded uncertainty of obtained results for the specific heat capacity and electrical resistivity of palladium was 5% and 1 - 2%, respectively.


  • Open Access

    A relative humidity calibration from 5°C to 45°C in a mixed-flow humidity generator

    by Nenad Milosevic, Nenad Stepanic, Marijana Babic

    The paper presents a method used in the Vinca Institute of Nuclear Sciences for a reliable and traceable relative humidity calibration in the temperature range from 5?C to 45?C. Inside a controllable temperature and humidity environment, supplied by a mixed-flow humidity generator, measurements of hygrometers under calibration are compared with those of calibrated reference instruments. A traceability chain from temperature to reference relative humidity and next to the hygrometers under calibrations is provided by using a chilled-mirror dew-point temperature system and precise relative humidity probes. Corresponding calibration uncertainties are analyzed, particularly those associated to the temperature uniformity of controlled calibration environment. Two examples of relative humidity calibration with dew-point and relative humidity reference measurements in the range from 15 to 75% of RH and 5?C to 45?C are presented and discussed.


  • Open Access

    Correction on the influence of thermal contact resistance in thermal conductivity measurements using the guarded hot plate method

    by Nenad Stepanic, Nenad Milosevic

    This work considers the influence of finite thermal contact resistances which exist in thermal conductivity measurements of homogeneous and poor thermal conductive materials using the guarded hot plate method. As an example of correction method proposed in this work, different experimental results obtained from a standard reference material sample (with the conductivity of about 1 W/mK) have been presented.