Boklae Cho
Research Subjects
Research Interests
Boklae Cho has a total of 14 co-authors. Here are the top co-authors by number of shared publications:
- Alfi Rodiansyah
Department of Information Display, College of Sciences, Kyung Hee University, Seoul 02447, Republic of Korea
1 shared publication Cheolsu Han
Korea Basic Science Institute, Daejeon 34133, South Korea
1 shared publicationChongdo Park
Accelerator Division, Pohang Accelerator Laboratory, POSTECH
1 shared publicationChuhei Oshima
Waseda University 2 Kagami Memorial Laboratory for Materials Science and Technology 2-8-26 Nishi-Waseda, Shinjuku-ku, Tokyo 169-0072, Japan
1 shared publication- Da Woon Kim
Department of Information Display, Kyung Hee University, Dongdaemun-gu, Seoul 024471, Korea
1 shared publication - Ha Rim Lee
Department of Information Display, Kyung Hee University, Dongdaemun-gu, Seoul 024471, Korea
1 shared publication
Latest Publications
- Open Access
- 26 July 2021
- Published by MDPI AG in Nanomaterials
- Vol. 11 (8) , 1918
Investigation of the Effect of Structural Properties of a Vertically Standing CNT Cold Cathode on Electron Beam Brightness and Resolution of Secondary Electron Images
Carbon nanotube (CNT)-based cold cathodes are promising sources of field emission electrons for advanced electron devices, particularly for ultra-high-resolution imaging systems, due to their high brightness and low energy spread. While the electron field emission properties of single-tip CNT cathodes have been intensively studied in the last few decades, a systematic study of the influencing factors on the electron beam properties of CNT cold cathodes and the resolution of the secondary electron images has been overlooked in this field. Here, we have systematically investigated the effect of the structural properties of a CNT cold cathode on the electron beam properties and resolution of secondary electron microscope (SEM) images. The aspect ratio (geometric factor) and the diameter of the tip of a vertically standing CNT cold cathode significantly affect the electron beam properties, including the beam size and brightness, and consequently determine the resolution of the secondary electron images obtained by SEM systems equipped with a CNT cold cathode module. Theoretical simulation elucidated the dependence of the structural features of CNT cold cathodes and electron beam properties on the contribution of edge-emitted electrons to the total field emission current. Investigating the correlations between the structural properties of CNT cold cathodes, the properties of the emitted electron beams, and the resolution of the secondary electron images captured by SEM equipped with CNT cold cathode modules is highly important and informative as a basic model.
- 26 July 2021
- Published by MDPI AG in Nanomaterials
- Vol. 11 (8) , 1918
Open AccessInvestigation of the Effect of Structural Properties of a Vertically Standing CNT Cold Cathode on Electron Beam Brightness and Resolution of Secondary Electron Images
Carbon nanotube (CNT)-based cold cathodes are promising sources of field emission electrons for advanced electron devices, particularly for ultra-high-resolution imaging systems, due to their high brightness and low energy spread. While the electron field emission properties of single-tip CNT cathodes have been intensively studied in the last few decades, a systematic study of the influencing factors on the electron beam properties of CNT cold cathodes and the resolution of the secondary electron images has been overlooked in this field. Here, we have systematically investigated the effect of the structural properties of a CNT cold cathode on the electron beam properties and resolution of secondary electron microscope (SEM) images. The aspect ratio (geometric factor) and the diameter of the tip of a vertically standing CNT cold cathode significantly affect the electron beam properties, including the beam size and brightness, and consequently determine the resolution of the secondary electron images obtained by SEM systems equipped with a CNT cold cathode module. Theoretical simulation elucidated the dependence of the structural features of CNT cold cathodes and electron beam properties on the contribution of edge-emitted electrons to the total field emission current. Investigating the correlations between the structural properties of CNT cold cathodes, the properties of the emitted electron beams, and the resolution of the secondary electron images captured by SEM equipped with CNT cold cathode modules is highly important and informative as a basic model.
- 1 February 2017
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 88 (2) , 023302
Edge shadow projection method for measuring the brightness of electron guns
The performance of an electron gun is evaluated in terms of the gun brightness. The brightness of an electron gun is typically measured by dividing the angular current density by the virtual source area. An electron gun brightness measurement system was constructed without an electron lens. The system consists of movable apertures (∅ 30, 50, 100, 200 ), a Faraday cup, and a phosphor screen. The Faraday cup is employed to measure the angular current density. The electron beam passes through an aperture and its shade is projected onto the phosphor screen. The virtual source position is determined by measuring the displacement of the aperture shade made by the movement of the aperture. The blurring width of the edge of the shadow on the screen is measured by a charged-coupled device camera to calculate the virtual source size. Brightness values of a tungsten filament electron gun were obtained and compared to reported values.- 1 February 2017
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 88 (2) , 023302
Edge shadow projection method for measuring the brightness of electron guns
The performance of an electron gun is evaluated in terms of the gun brightness. The brightness of an electron gun is typically measured by dividing the angular current density by the virtual source area. An electron gun brightness measurement system was constructed without an electron lens. The system consists of movable apertures (∅ 30, 50, 100, 200 ), a Faraday cup, and a phosphor screen. The Faraday cup is employed to measure the angular current density. The electron beam passes through an aperture and its shade is projected onto the phosphor screen. The virtual source position is determined by measuring the displacement of the aperture shade made by the movement of the aperture. The blurring width of the edge of the shadow on the screen is measured by a charged-coupled device camera to calculate the virtual source size. Brightness values of a tungsten filament electron gun were obtained and compared to reported values.- Open Access
- 13 December 2016
- Published by MyJove Corporation in Journal of Visualized Experiments
- No. 118,p. e55017
Measurement of Outgassing Rates of Steels
A protocol for the measurement of outgassing rates of hydrogen from ordinary steel vacuum chambers using the rate-of-pressure rise...
- 13 December 2016
- Published by MyJove Corporation in Journal of Visualized Experiments
- No. 118,p. e55017
Open AccessMeasurement of Outgassing Rates of Steels
A protocol for the measurement of outgassing rates of hydrogen from ordinary steel vacuum chambers using the rate-of-pressure rise...
- Open Access
- 6 December 2016
- Published by American Vacuum Society in Journal of Vacuum Science & Technology A
- Vol. 35 (2) , 020604
Low-carbon steel ultra-high-vacuum Schottky emitter electron gun with double O-rings for axis adjustment
With the aim to create a simpler structure and reduce the production cost of an existing Schottky emitter-scanning electron microscope (SE-SEM), the authors have built and tested a double-O-ring electron gun which is also compatible with ultrahigh vacuum (UHV). Specifically, the gun and column of the SEM consist of low-carbon steel, of which the magnetic shielding effect is greater than that of stainless steel, allowing magnification of ×200 000 in the adapted SEM base without additional magnetic shielding material, such as permalloy or mu-metal. The position of the electron gun can be adjusted along the horizontal axis while maintaining the UHV condition. Excellent beam current stability with less than 1% variation for more than 1 h was noted. Therefore, the authors anticipate that the double-O-ring electron gun and column of low-carbon steel together represent an inexpensive and uncomplicated SE-SEM compared to existing types.
- 6 December 2016
- Published by American Vacuum Society in Journal of Vacuum Science & Technology A
- Vol. 35 (2) , 020604
Open AccessLow-carbon steel ultra-high-vacuum Schottky emitter electron gun with double O-rings for axis adjustment
With the aim to create a simpler structure and reduce the production cost of an existing Schottky emitter-scanning electron microscope (SE-SEM), the authors have built and tested a double-O-ring electron gun which is also compatible with ultrahigh vacuum (UHV). Specifically, the gun and column of the SEM consist of low-carbon steel, of which the magnetic shielding effect is greater than that of stainless steel, allowing magnification of ×200 000 in the adapted SEM base without additional magnetic shielding material, such as permalloy or mu-metal. The position of the electron gun can be adjusted along the horizontal axis while maintaining the UHV condition. Excellent beam current stability with less than 1% variation for more than 1 h was noted. Therefore, the authors anticipate that the double-O-ring electron gun and column of low-carbon steel together represent an inexpensive and uncomplicated SE-SEM compared to existing types.
- 1 January 2013
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 84 (1) , 013305
W(310) cold-field emission characteristics reflecting the vacuum states of an extreme high vacuum electron gun
An extremely high vacuum cold-field electron emission (CFE) gun operating at pressures ranging from ∼10−8 Pa to ∼10−10 Pa was constructed. Only the CFE current emitting from W(310) surfaces revealed the existence of a “stable region” with high current angular density just after tip flash heating. In the “stable region,” the CFE current was damped very slowly. The presence of non-hydrogen gas eliminated this region from the plot. Improvement of the vacuum prolonged the 90% damping time of the CFE current from ∼10 min to 800 min. The current angular density I′ of CFE current was 60 and 250 μA/sr in the “stable region” for total CFE currents of 10 and 50 μA, respectively. These results were about three times larger than I′ when measured after the complete damping of the CFE current. The CFE gun generated bright scanning transmission electron microscopy images of a carbon nanotube at 30 kV.
- 1 January 2013
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 84 (1) , 013305
W(310) cold-field emission characteristics reflecting the vacuum states of an extreme high vacuum electron gun
An extremely high vacuum cold-field electron emission (CFE) gun operating at pressures ranging from ∼10−8 Pa to ∼10−10 Pa was constructed. Only the CFE current emitting from W(310) surfaces revealed the existence of a “stable region” with high current angular density just after tip flash heating. In the “stable region,” the CFE current was damped very slowly. The presence of non-hydrogen gas eliminated this region from the plot. Improvement of the vacuum prolonged the 90% damping time of the CFE current from ∼10 min to 800 min. The current angular density I′ of CFE current was 60 and 250 μA/sr in the “stable region” for total CFE currents of 10 and 50 μA, respectively. These results were about three times larger than I′ when measured after the complete damping of the CFE current. The CFE gun generated bright scanning transmission electron microscopy images of a carbon nanotube at 30 kV.