Belkacem Merzouk
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Belkacem Merzouk has a total of 47 co-authors. Here are the top co-authors by number of shared publications:
- Khodir Madani
Laboratoire de Biomathématiques, Biophysique, Biochimie, et Scientométrie (L3BS), Faculté des Sciences de la Nature et de la Vie, Université de Bejaia, Bejaia 06000, Algeria
8 shared publications Jean-Pierre Leclerc
6 shared publicationsFrançois Lapicque
4 shared publications- Nawel Adjeroud
Université de Bejaia
4 shared publications A. Sekki
3 shared publicationsB. Gourich
3 shared publications
Latest Publications
- 2 August 2026
- Published by Springer Nature
- p. 459-462
Evaluation and Mapping of Erosion Risk by RUSLE Model in the Boussellam Catchment in Northeast Algeria
- 2 August 2026
- Published by Springer Nature
- p. 459-462
Evaluation and Mapping of Erosion Risk by RUSLE Model in the Boussellam Catchment in Northeast Algeria
- Open Access
- 30 June 2026
- Published by University of M'Sila in Journal of Advanced Applied Technology and Engineering
- Vol. 1 (02) , 68-79
Spatial assessment of groundwater recharge, agricultural pumping, and hydrodynamic stress in the complexe terminal aquifer (Ghardaïa, Algeria) using GIS and Remote Sensing
This study develops an integrated GIS-ArcGIS, remote sensing (NDVI), and multi-criteria decision analysis (FAHP) framework to evaluate the water balance of the unconfined Complexe Terminal aquifer in the hyper-arid region of Ghardaïa, Algeria. While classical macro-spatial approaches suggest a reassuring surplus balance of +12.65 hm3/year with modeled natural recharge (sim 47.81 hm3/year) exceeding actual satellite-derived agricultural pumping (sim 35.16 hm3/year) granular top-down discretization using Thiessen polygons exposes severe localized hydrodynamic stress. Historic oasis perimeters like Mansourah and Bounoura face acute groundwater mining conditions, where real volumetric abstractions overwhelm localized recharge by a factor of 10 to 12.7, resulting in irreversible piezometric drawdown. Conversely, massive, uncultivated peripheral cells in Guerrara mathematically distort the macro-balance. To mitigate local depletion, the validated FAHP model successfully maps optimal upstream green-engineering retention sites along Wadi M'zab and Wadi Metlili to maximize floodwater infiltration and artificially stabilize vulnerable water tables.
- 30 June 2026
- Published by University of M'Sila in Journal of Advanced Applied Technology and Engineering
- Vol. 1 (02) , 68-79
Open AccessSpatial assessment of groundwater recharge, agricultural pumping, and hydrodynamic stress in the complexe terminal aquifer (Ghardaïa, Algeria) using GIS and Remote Sensing
This study develops an integrated GIS-ArcGIS, remote sensing (NDVI), and multi-criteria decision analysis (FAHP) framework to evaluate the water balance of the unconfined Complexe Terminal aquifer in the hyper-arid region of Ghardaïa, Algeria. While classical macro-spatial approaches suggest a reassuring surplus balance of +12.65 hm3/year with modeled natural recharge (sim 47.81 hm3/year) exceeding actual satellite-derived agricultural pumping (sim 35.16 hm3/year) granular top-down discretization using Thiessen polygons exposes severe localized hydrodynamic stress. Historic oasis perimeters like Mansourah and Bounoura face acute groundwater mining conditions, where real volumetric abstractions overwhelm localized recharge by a factor of 10 to 12.7, resulting in irreversible piezometric drawdown. Conversely, massive, uncultivated peripheral cells in Guerrara mathematically distort the macro-balance. To mitigate local depletion, the validated FAHP model successfully maps optimal upstream green-engineering retention sites along Wadi M'zab and Wadi Metlili to maximize floodwater infiltration and artificially stabilize vulnerable water tables.
- Open Access
- 30 June 2026
- Published by University of M'Sila in Journal of Advanced Applied Technology and Engineering
- Vol. 1 (02) , 19-28
Assessment and modeling of COD removal efficiency in textile wastewater using electrocoagulation
In electrocoagulation (EC), coagulants are generated in situ through the corrosion of sacrificial anodes under the application of a direct current (DC) voltage. Simultaneously, electrolytic hydrogen gas (H2) is produced at the cathode. Aluminum and iron are commonly used as anode materials; their dissolution leads to the formation of hydroxides and polymeric hydroxides. These species act as coagulants capable of destabilizing colloidal suspensions and emulsions, as well as adsorbing, neutralizing, or precipitating dissolved pollutants. Ultimately, they form flocs that can be removed by either sedimentation or flotation. In this study, the influence of key operating parameters of EC, such as current density (j), solution pH, and conductivity (κ), was investigated for the removal of a red textile dye. The results show that current density has a significant effect on the removal of turbidity, color, and chemical oxygen demand (COD). Removal efficiencies of 77.25% for turbidity, 86.55% for color, and 78.5% for COD were obtained under the following conditions: initial dye concentration C₀ = 100 mg/L, j = 150 A/m², κ = 3.56 mS/cm, inlet flow rate Q = 0.15 L/min, treatment time t = 40 min, and initial pH = 7.65. Finally, a model relating COD removal to aluminum consumption was proposed, which satisfactorily described the experimental results.
- 30 June 2026
- Published by University of M'Sila in Journal of Advanced Applied Technology and Engineering
- Vol. 1 (02) , 19-28
Open AccessAssessment and modeling of COD removal efficiency in textile wastewater using electrocoagulation
In electrocoagulation (EC), coagulants are generated in situ through the corrosion of sacrificial anodes under the application of a direct current (DC) voltage. Simultaneously, electrolytic hydrogen gas (H2) is produced at the cathode. Aluminum and iron are commonly used as anode materials; their dissolution leads to the formation of hydroxides and polymeric hydroxides. These species act as coagulants capable of destabilizing colloidal suspensions and emulsions, as well as adsorbing, neutralizing, or precipitating dissolved pollutants. Ultimately, they form flocs that can be removed by either sedimentation or flotation. In this study, the influence of key operating parameters of EC, such as current density (j), solution pH, and conductivity (κ), was investigated for the removal of a red textile dye. The results show that current density has a significant effect on the removal of turbidity, color, and chemical oxygen demand (COD). Removal efficiencies of 77.25% for turbidity, 86.55% for color, and 78.5% for COD were obtained under the following conditions: initial dye concentration C₀ = 100 mg/L, j = 150 A/m², κ = 3.56 mS/cm, inlet flow rate Q = 0.15 L/min, treatment time t = 40 min, and initial pH = 7.65. Finally, a model relating COD removal to aluminum consumption was proposed, which satisfactorily described the experimental results.
- Open Access
- 1 January 2025
- Published by National Library of Serbia
- Vol. 105 (2) , 157-174
Groundwater quality assessment using spatio-temporal evolution of water quality index and GIS in K'sob watershed (semiarid area-east Algeria)
Groundwater is a crucial natural resource, particularly in arid and semi-arid regions, where it serves as a primary source for drinking and irrigation. The K'sob watershed in Algeria is significant for its groundwater resources. This study aims to assess the ground-water quality of the K'sob aquifer and investigate the spatial distribution of quality parameters to identify areas with the best drinking water quality. The study combines the Water Quality Index (WQI) and Geographic Information System (GIS) methodologies. Twenty groundwater samples were collected and analyzed for major cations and anions. Spatial distribution maps of parameters including pH, temperature (T?), electrical conductivity (EC), total hardness (TH), turbidity, total alkalinity (TAC), chloride (Cl-), nitrate (NO3-), bicarbonate (HCO3-), calcium (Ca2+), and magnesium (Mg2+) were created using the Inverse Distance Weighted (IDW) interpolation method in a GIS environment. The WQI results revealed temporal variations in groundwater quality between 2022 and 2024. In 2022, 5% of samples were of excellent quality, 60% good quality, 15% poor quality, 5% very poor quality, and 15% unsuitable for drinking purposes. By 2024, samples classified as excellent quality increased to 25%, while good quality samples decreased to 35%. Poor quality samples remained stable at 15%, very poor quality samples increased to 10%, and those unsuitable for drinking remained at 15%. This research demonstrates the effective combination of GIS and WQI in assessing groundwater quality over space and time. The findings can support decision-makers in planning the operation and management of groundwater resources.
- 1 January 2025
- Published by National Library of Serbia
- Vol. 105 (2) , 157-174
Open AccessGroundwater quality assessment using spatio-temporal evolution of water quality index and GIS in K'sob watershed (semiarid area-east Algeria)
Groundwater is a crucial natural resource, particularly in arid and semi-arid regions, where it serves as a primary source for drinking and irrigation. The K'sob watershed in Algeria is significant for its groundwater resources. This study aims to assess the ground-water quality of the K'sob aquifer and investigate the spatial distribution of quality parameters to identify areas with the best drinking water quality. The study combines the Water Quality Index (WQI) and Geographic Information System (GIS) methodologies. Twenty groundwater samples were collected and analyzed for major cations and anions. Spatial distribution maps of parameters including pH, temperature (T?), electrical conductivity (EC), total hardness (TH), turbidity, total alkalinity (TAC), chloride (Cl-), nitrate (NO3-), bicarbonate (HCO3-), calcium (Ca2+), and magnesium (Mg2+) were created using the Inverse Distance Weighted (IDW) interpolation method in a GIS environment. The WQI results revealed temporal variations in groundwater quality between 2022 and 2024. In 2022, 5% of samples were of excellent quality, 60% good quality, 15% poor quality, 5% very poor quality, and 15% unsuitable for drinking purposes. By 2024, samples classified as excellent quality increased to 25%, while good quality samples decreased to 35%. Poor quality samples remained stable at 15%, very poor quality samples increased to 10%, and those unsuitable for drinking remained at 15%. This research demonstrates the effective combination of GIS and WQI in assessing groundwater quality over space and time. The findings can support decision-makers in planning the operation and management of groundwater resources.
- 6 July 2019
- Published by Springer Nature in Journal of Mountain Science
- Vol. 16 (7) , 1606-1615
Mapping surface water erosion potential in the Soummam watershed in Northeast Algeria with RUSLE model
- 6 July 2019
- Published by Springer Nature in Journal of Mountain Science
- Vol. 16 (7) , 1606-1615
Mapping surface water erosion potential in the Soummam watershed in Northeast Algeria with RUSLE model
- 1 March 2018
- Published by Elsevier in Sustainable Chemistry and Pharmacy
- Vol. 7, 27-35
Removal of a textile dye using photovoltaic electrocoagulation
- 1 March 2018
- Published by Elsevier in Sustainable Chemistry and Pharmacy
- Vol. 7, 27-35
Removal of a textile dye using photovoltaic electrocoagulation
- 1 February 2018
- Published by Elsevier in Journal of Electroanalytical Chemistry
- Vol. 811, 26-36
Effect of Opuntia ficus indica mucilage on copper removal from water by electrocoagulation-electroflotation technique
- 1 February 2018
- Published by Elsevier in Journal of Electroanalytical Chemistry
- Vol. 811, 26-36
Effect of Opuntia ficus indica mucilage on copper removal from water by electrocoagulation-electroflotation technique
- 19 December 2017
- Published by Wiley in Water and Environment Journal
- Vol. 32 (3) , 321-332
Enhanced electrocoagulation–electroflotation for turbidity removal by Opuntia ficus indica cladode mucilage
The optimisation of the electrocoagulation‐electroflotation (EC‐EF) process assisted by the mucilage of the Opuntia ficus indica (OFI), on the turbidity removal was performed through the response surface methodology (RSM). For a solution of 300 mg/L of silica gel, high turbidity removal (93.14% ± 1.31) was obtained under the optimal conditions of 2.5 mg/L, 21.2 V, 9.65 and 2.61 mS/cm for the mucilage concentration, voltage, pH and conductivity, respectively, this experimental value was close to the predicted value of 92.96% ± 0.3. OFI mucilage increases turbidity removal efficiency and reduces specific energy consumption at a fixed current density. The turbidity removal of the EC‐EF process was improved by 30.94% compared with the conventional EC–EF (EC–EF without OFI mucilage) which shows 62.02% ± 1.45 of turbidity removal.
- 19 December 2017
- Published by Wiley in Water and Environment Journal
- Vol. 32 (3) , 321-332
Enhanced electrocoagulation–electroflotation for turbidity removal by Opuntia ficus indica cladode mucilage
The optimisation of the electrocoagulation‐electroflotation (EC‐EF) process assisted by the mucilage of the Opuntia ficus indica (OFI), on the turbidity removal was performed through the response surface methodology (RSM). For a solution of 300 mg/L of silica gel, high turbidity removal (93.14% ± 1.31) was obtained under the optimal conditions of 2.5 mg/L, 21.2 V, 9.65 and 2.61 mS/cm for the mucilage concentration, voltage, pH and conductivity, respectively, this experimental value was close to the predicted value of 92.96% ± 0.3. OFI mucilage increases turbidity removal efficiency and reduces specific energy consumption at a fixed current density. The turbidity removal of the EC‐EF process was improved by 30.94% compared with the conventional EC–EF (EC–EF without OFI mucilage) which shows 62.02% ± 1.45 of turbidity removal.
- Open Access
- 1 April 2017
- Published by Elsevier in Desalination and Water Treatment
- Vol. 73, 330-338
Influence of electrodes connection mode and type of current in electrocoagulation process on the removal of a textile dye
- 1 April 2017
- Published by Elsevier in Desalination and Water Treatment
- Vol. 73, 330-338
Open AccessInfluence of electrodes connection mode and type of current in electrocoagulation process on the removal of a textile dye
- Open Access
- 1 October 2016
- Published by Elsevier in Desalination and Water Treatment
- Vol. 57 (48-49) , 22764-22773
Removal of reactive textile dye from aqueous solutions by electrocoagulation in a continuous cell
In electrocoagulation (EC), coagulants are delivered in situ using the corrosion of sacrificial anodes when a DC voltage is applied. Simultaneously, electrolytic gases (H2) are generated at the cathode. Aluminum and iron materials are usually used as anodes, the dissolution of which produces hydroxides and polymeric hydroxides. These coagulants are able to destabilize colloidal suspensions and emulsions, to adsorb, neutralize, or precipitate dissolved polluting species, and finally to form flocs that can be removed either by settling or flotation. The purpose of this study was to investigate the effects of the operating parameters, such as initial pH, initial concentration (C0), residence time (τ), current density (j), and inlet flow rate (Q), on the removal of a red nylosan dye by EC process using aluminum electrode in a continuous electrochemical reactor. FTIR analysis was conducted to interpret the functional groups involved during the EC process. It was found that the increase in the current density up to 100 A m−2 had increased the dye removal efficiency and the optimum inlet flow rate for EC process was the minimum at 15 L h−1 and it has increased the electrical energy consumption. A rate of abatement of about 90% for turbidity and 97% for color was observed, when the initial concentration of the dye C0 was lower than 300 mg L−1, current density j = 300 A m−2, conductivity κ = 2.54 mS cm−1, inlet flow rate Q = 15 L h−1, residence time τ = 35 min, and initial pH ranged from 2.3 to 8.8. The specific electrical energy consumption was 19.5 kW h per kilogramme of removed dye.
- 1 October 2016
- Published by Elsevier in Desalination and Water Treatment
- Vol. 57 (48-49) , 22764-22773
Open AccessRemoval of reactive textile dye from aqueous solutions by electrocoagulation in a continuous cell
In electrocoagulation (EC), coagulants are delivered in situ using the corrosion of sacrificial anodes when a DC voltage is applied. Simultaneously, electrolytic gases (H2) are generated at the cathode. Aluminum and iron materials are usually used as anodes, the dissolution of which produces hydroxides and polymeric hydroxides. These coagulants are able to destabilize colloidal suspensions and emulsions, to adsorb, neutralize, or precipitate dissolved polluting species, and finally to form flocs that can be removed either by settling or flotation. The purpose of this study was to investigate the effects of the operating parameters, such as initial pH, initial concentration (C0), residence time (τ), current density (j), and inlet flow rate (Q), on the removal of a red nylosan dye by EC process using aluminum electrode in a continuous electrochemical reactor. FTIR analysis was conducted to interpret the functional groups involved during the EC process. It was found that the increase in the current density up to 100 A m−2 had increased the dye removal efficiency and the optimum inlet flow rate for EC process was the minimum at 15 L h−1 and it has increased the electrical energy consumption. A rate of abatement of about 90% for turbidity and 97% for color was observed, when the initial concentration of the dye C0 was lower than 300 mg L−1, current density j = 300 A m−2, conductivity κ = 2.54 mS cm−1, inlet flow rate Q = 15 L h−1, residence time τ = 35 min, and initial pH ranged from 2.3 to 8.8. The specific electrical energy consumption was 19.5 kW h per kilogramme of removed dye.