Jiali Liu
Research Subjects
Jiali Liu has a total of 42 co-authors. Here are the top co-authors by number of shared publications:
- Liwei Jiang
Beihang University
18 shared publications - Wei Quan
School of Instrumentation and Optoelectronic Engineering, Beihang University 1 , Beijing 100191
8 shared publications - Chi Fang
National Institute of Extremely-Weak Magnetic Field Infrastructure
6 shared publications - Yixiang Liang
School of Instrumentation and Optoelectronic Engineering, Beihang University, Beijing, China
6 shared publications Wei Quan
5 shared publications- Yuntian Zou
Key Laboratory of Ultra-Weak Magnetic Field Measurement Technology, Ministry of Education, Institute of Large-Scale Scientific Facility and Centre for Zero Magnetic Field Science, Beihang University, Beijing, China
5 shared publications
Latest Publications
- 21 September 2026
- Published by IOP Publishing in Quantum Science and Technology
- Vol. 11 (4) , 045051
Single-beam atomic magnetometry with sub-nanotesla heading error based on hyperfine alignment resonances
Heading error is a major limitation for resonance-based atomic magnetometers operating in the geomagnetic-field range, where the magnetic-field direction often changes with respect to the sensor. Here, we investigate the physical origin of heading error in a single-beam amplitude-modulated nonlinear magneto-optical rotation magnetometer based on the hyperfine alignment resonances of the 87 Rb D1 line in a buffer-gas vapor cell. Unlike orientation-based magnetometers, where nonlinear Zeeman effects usually constitute a major source of heading error, the F = 2 alignment resonance spectrum maintains a stable center frequency under different magnetic-field orientations when the individual resonance components are unresolved. In practical single-beam measurements, the observed heading error is associated with an orientation-dependent residual spectral background, which breaks the apparent symmetry of the alignment-resonance profile and biases the extracted center frequency. To suppress this background-induced bias, we propose a multi-point frequency extraction method that retrieves the resonance center from distorted single-beam spectra. In unshielded geomagnetic-field measurements, the equal-weight pooled peak-to-peak heading-error estimate for the F = 2 manifold is reduced to 0.32 nT, with a one-sided 95% upper coverage limit of 0.90 nT. Separately, an estimated photon-shot-noise-limited sensitivity of about 23 fT / Hz 1 / 2 is obtained. These results provide a compact route to low-heading-error and high-sensitivity atomic magnetometry for practical geomagnetic-field quantum sensing.
- 21 September 2026
- Published by IOP Publishing in Quantum Science and Technology
- Vol. 11 (4) , 045051
Single-beam atomic magnetometry with sub-nanotesla heading error based on hyperfine alignment resonances
Heading error is a major limitation for resonance-based atomic magnetometers operating in the geomagnetic-field range, where the magnetic-field direction often changes with respect to the sensor. Here, we investigate the physical origin of heading error in a single-beam amplitude-modulated nonlinear magneto-optical rotation magnetometer based on the hyperfine alignment resonances of the 87 Rb D1 line in a buffer-gas vapor cell. Unlike orientation-based magnetometers, where nonlinear Zeeman effects usually constitute a major source of heading error, the F = 2 alignment resonance spectrum maintains a stable center frequency under different magnetic-field orientations when the individual resonance components are unresolved. In practical single-beam measurements, the observed heading error is associated with an orientation-dependent residual spectral background, which breaks the apparent symmetry of the alignment-resonance profile and biases the extracted center frequency. To suppress this background-induced bias, we propose a multi-point frequency extraction method that retrieves the resonance center from distorted single-beam spectra. In unshielded geomagnetic-field measurements, the equal-weight pooled peak-to-peak heading-error estimate for the F = 2 manifold is reduced to 0.32 nT, with a one-sided 95% upper coverage limit of 0.90 nT. Separately, an estimated photon-shot-noise-limited sensitivity of about 23 fT / Hz 1 / 2 is obtained. These results provide a compact route to low-heading-error and high-sensitivity atomic magnetometry for practical geomagnetic-field quantum sensing.
- Open Access
- 19 March 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Photonics Journal
- Vol. 18 (2) , 1-6
Modeling and Measuring of Light Shift in Optically Pumped Atomic Magnetometers
The light shift is a significant error source of optically pumped atomic magnetometers (OPAMs), requiring accurate calculation or measurement to assess its impact on the accuracy of OPAMs. In this paper, a light shift theoretical model considering the gradient of the pump light is established, providing a detailed description of the light shift distribution within the cell under the influence of multiple parameters. Additionally, a light shift measurement method through magneto optical angle adjustment (MOAA) is proposed, enabling convenient measurement of the light shift. The correctness of the proposed model and the effectiveness of the MOAA method are validated through experiments. The proposed model and method contribute to improving the accuracy of OPAMs and enhancing their performance in practical applications.
- 19 March 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Photonics Journal
- Vol. 18 (2) , 1-6
Open AccessModeling and Measuring of Light Shift in Optically Pumped Atomic Magnetometers
The light shift is a significant error source of optically pumped atomic magnetometers (OPAMs), requiring accurate calculation or measurement to assess its impact on the accuracy of OPAMs. In this paper, a light shift theoretical model considering the gradient of the pump light is established, providing a detailed description of the light shift distribution within the cell under the influence of multiple parameters. Additionally, a light shift measurement method through magneto optical angle adjustment (MOAA) is proposed, enabling convenient measurement of the light shift. The correctness of the proposed model and the effectiveness of the MOAA method are validated through experiments. The proposed model and method contribute to improving the accuracy of OPAMs and enhancing their performance in practical applications.
- 29 January 2026
- Published by Wiley in Advanced Quantum Technologies
- Vol. 9 (1)
Optimal Magneto‐Optical Angle in Single‐Beam Optically Pumped Atomic Magnetometers Considering the Spatial Distribution of Spin Polarization
Single‐beam optically pumped atomic magnetometers (OPAMs) are promising tools for biomagnetic measurements in nonzero‐field environments owing to their high sensitivity and compactness. However, the angle between the external bias magnetic field and the pump light affects the spin polarization of the atomic ensemble, thereby influencing the magnetometer performance and making the optimization of the magneto‐optical angle essential. In this study, a spatially resolved steady‐state spin polarization model incorporating the magneto‐optical angle is established for the first time, and an analytical expression of the spin precession signal under RF magnetic field excitation is derived. It is demonstrated that an optimal angle exists at which the magnetometer exhibits the maximum response and the highest sensitivity, which is experimentally determined to be 26° in our single‐beam OPAM. At this angle, the combined influence of the steady‐state spin polarization, spin precession projection, transmitted light intensity, and transverse spin relaxation reaches an optimal overall state, leading to a 14% enhancement in sensitivity and a 32% reduction in detection noise compared with the conventional 45° configuration. These findings provide guidance for optimizing the experimental parameters of single‐beam OPAMs for weak magnetic signal detection in nonzero‐field environments.
- 29 January 2026
- Published by Wiley in Advanced Quantum Technologies
- Vol. 9 (1)
Optimal Magneto‐Optical Angle in Single‐Beam Optically Pumped Atomic Magnetometers Considering the Spatial Distribution of Spin Polarization
Single‐beam optically pumped atomic magnetometers (OPAMs) are promising tools for biomagnetic measurements in nonzero‐field environments owing to their high sensitivity and compactness. However, the angle between the external bias magnetic field and the pump light affects the spin polarization of the atomic ensemble, thereby influencing the magnetometer performance and making the optimization of the magneto‐optical angle essential. In this study, a spatially resolved steady‐state spin polarization model incorporating the magneto‐optical angle is established for the first time, and an analytical expression of the spin precession signal under RF magnetic field excitation is derived. It is demonstrated that an optimal angle exists at which the magnetometer exhibits the maximum response and the highest sensitivity, which is experimentally determined to be 26° in our single‐beam OPAM. At this angle, the combined influence of the steady‐state spin polarization, spin precession projection, transmitted light intensity, and transverse spin relaxation reaches an optimal overall state, leading to a 14% enhancement in sensitivity and a 32% reduction in detection noise compared with the conventional 45° configuration. These findings provide guidance for optimizing the experimental parameters of single‐beam OPAMs for weak magnetic signal detection in nonzero‐field environments.
- 11 December 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 74 (00189456) , 1-10
Model Predictive Control for Real-Time Stabilization of Magnetic Field Using NMOR Atomic Magnetometers
Accurate calibration of atomic magnetometers and the detection of weak magnetic signals in applications such as biomagnetism and fundamental physics experiments are hindered by low-frequency environmental disturbances that mask useful signals. To address this, we implement a magnetic field reference source system that integrates an NMOR atomic magnetometer with a predictive-control-based active compensation loop. The system establishes a quiet and stable magnetic environment, supporting both magnetometer calibration and weak-field measurements. By modeling the NMOR response, the relation between field variation and demodulated phase is derived and used as a robust error signal for stabilization. Under a 10000 nT bias field, the system suppresses low-frequency noise by 42.6 dB compared with passive shielding and achieves residual levels of 264 fT/√Hz at 0.1 Hz. Allan deviation analysis further verifies improved long-term stability, enabling accurate biomagnetic and low-field NMR studies as well as performance evaluation of precision magnetometers.
- 11 December 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 74 (00189456) , 1-10
Model Predictive Control for Real-Time Stabilization of Magnetic Field Using NMOR Atomic Magnetometers
Accurate calibration of atomic magnetometers and the detection of weak magnetic signals in applications such as biomagnetism and fundamental physics experiments are hindered by low-frequency environmental disturbances that mask useful signals. To address this, we implement a magnetic field reference source system that integrates an NMOR atomic magnetometer with a predictive-control-based active compensation loop. The system establishes a quiet and stable magnetic environment, supporting both magnetometer calibration and weak-field measurements. By modeling the NMOR response, the relation between field variation and demodulated phase is derived and used as a robust error signal for stabilization. Under a 10000 nT bias field, the system suppresses low-frequency noise by 42.6 dB compared with passive shielding and achieves residual levels of 264 fT/√Hz at 0.1 Hz. Allan deviation analysis further verifies improved long-term stability, enabling accurate biomagnetic and low-field NMR studies as well as performance evaluation of precision magnetometers.
- 25 July 2025
- Published by Optica Publishing Group in Optics Express
- Vol. 33 (15) , 32663-32674
Refined analysis and representation of atomic polarization in NMOR atomic magnetometers
The nonlinear magneto-optical rotation (NMOR) atomic magnetometer is a highly sensitive total-field device with significant applications in fundamental physics, geophysics, and biomedical monitoring. The atomic polarization, which is optically induced through resonant light pumping, plays a pivotal role in determining the sensitivity and stability of the magnetometer. In this paper, refined analysis and representation of atomic polarization in NMOR atomic magnetometers are presented through the establishment of a three-dimensional polarization distribution model based on the rate equation. The polarization characteristics of the single-beam pump and repump modes are compared, and the scale factors of both modes are experimentally measured. Both simulation and experimental results demonstrate that the proposed model accurately captures the spatial distribution of optically induced polarization, which is essential for improving the performance and extending the application potential of NMOR magnetometers in high-sensitivity optical sensing systems.
- 25 July 2025
- Published by Optica Publishing Group in Optics Express
- Vol. 33 (15) , 32663-32674
Refined analysis and representation of atomic polarization in NMOR atomic magnetometers
The nonlinear magneto-optical rotation (NMOR) atomic magnetometer is a highly sensitive total-field device with significant applications in fundamental physics, geophysics, and biomedical monitoring. The atomic polarization, which is optically induced through resonant light pumping, plays a pivotal role in determining the sensitivity and stability of the magnetometer. In this paper, refined analysis and representation of atomic polarization in NMOR atomic magnetometers are presented through the establishment of a three-dimensional polarization distribution model based on the rate equation. The polarization characteristics of the single-beam pump and repump modes are compared, and the scale factors of both modes are experimentally measured. Both simulation and experimental results demonstrate that the proposed model accurately captures the spatial distribution of optically induced polarization, which is essential for improving the performance and extending the application potential of NMOR magnetometers in high-sensitivity optical sensing systems.
- 14 February 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 74 (00189456) , 1-7
Enhancement of Electron-Spin Polarization Using Magneto-Optical Synchronous Modulation
Resonance-based optically pumped magnetometers have been widely used in various fields of magnetic field measurement. The electron-spin polarization affects the magnetometer response, which directly determines the signal-to-noise ratio and sensitivity performance of the magnetometer. The usual way to increase electron-spin polarization is to increase the pumping light power, which also causes the optical broadening of resonance linewidth. In this work, we propose a novel method of magneto-optical synchronous modulation to enhance the electron-spin polarization without introducing additional optical broadening, which can enhance the response and reduce the dead zone of traditional resonance-based magnetometers. This method excites atomic resonance by the modulated transverse magnetic field and longitudinal pumping light with Larmor frequency. The theoretical model of magneto-optical synchronous modulation magnetometer is established and verified experimentally. Compared with single magnetic field modulation and single optical field modulation, the magneto-optical synchronous modulation method improves the magnetometer response signal, which is directly related to the sensitivity performance of magnetometers. Moreover, this method reduces the measurement dead zone to a plane compared to conventional magnetic field resonance magnetometers.
- 14 February 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 74 (00189456) , 1-7
Enhancement of Electron-Spin Polarization Using Magneto-Optical Synchronous Modulation
Resonance-based optically pumped magnetometers have been widely used in various fields of magnetic field measurement. The electron-spin polarization affects the magnetometer response, which directly determines the signal-to-noise ratio and sensitivity performance of the magnetometer. The usual way to increase electron-spin polarization is to increase the pumping light power, which also causes the optical broadening of resonance linewidth. In this work, we propose a novel method of magneto-optical synchronous modulation to enhance the electron-spin polarization without introducing additional optical broadening, which can enhance the response and reduce the dead zone of traditional resonance-based magnetometers. This method excites atomic resonance by the modulated transverse magnetic field and longitudinal pumping light with Larmor frequency. The theoretical model of magneto-optical synchronous modulation magnetometer is established and verified experimentally. Compared with single magnetic field modulation and single optical field modulation, the magneto-optical synchronous modulation method improves the magnetometer response signal, which is directly related to the sensitivity performance of magnetometers. Moreover, this method reduces the measurement dead zone to a plane compared to conventional magnetic field resonance magnetometers.
- 28 October 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 73 (00189456) , 1-9
Suppression of Heading Error in Bell-Bloom Atomic Magnetometer by Controlling RF Magnetic Field
The atomic magnetometers operated in earth-scale magnetic field are susceptible to the nonlinear Zeeman (NLZ) effect, resulting in multiple resonance peaks and heading error, which restricts their practical applications. We introduce a spin-locking method based on magnetic field modulation to overcome the NLZ effect and thus suppress the heading error in atomic magnetometers. The suppression effect of spin-locking is proportional to the amplitude of the modulation field. However, an excessively high modulation field amplitude can lead to broadening of the measurement linewidth. A novel model characterizing the linewidth for the amplitude of modulated magnetic field under different environmental magnetic field is established by considering the NLZ effect. From the test results, the novel model can more accurately predict the linewidth under different environmental magnetic fields compared to traditional models. The optimized amplitude of modulated magnetic field is obtained based on the linewidth model, and the heading error is suppressed by about 80 % within the magnetic field inclination angle of 28.76 °. The theory and method presented here are important for the application of magnetometers in earthscale magnetic field, which can suppress the heading error while keeping the linewidth unchanged.
- 28 October 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 73 (00189456) , 1-9
Suppression of Heading Error in Bell-Bloom Atomic Magnetometer by Controlling RF Magnetic Field
The atomic magnetometers operated in earth-scale magnetic field are susceptible to the nonlinear Zeeman (NLZ) effect, resulting in multiple resonance peaks and heading error, which restricts their practical applications. We introduce a spin-locking method based on magnetic field modulation to overcome the NLZ effect and thus suppress the heading error in atomic magnetometers. The suppression effect of spin-locking is proportional to the amplitude of the modulation field. However, an excessively high modulation field amplitude can lead to broadening of the measurement linewidth. A novel model characterizing the linewidth for the amplitude of modulated magnetic field under different environmental magnetic field is established by considering the NLZ effect. From the test results, the novel model can more accurately predict the linewidth under different environmental magnetic fields compared to traditional models. The optimized amplitude of modulated magnetic field is obtained based on the linewidth model, and the heading error is suppressed by about 80 % within the magnetic field inclination angle of 28.76 °. The theory and method presented here are important for the application of magnetometers in earthscale magnetic field, which can suppress the heading error while keeping the linewidth unchanged.
- 15 July 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 73 (00189456) , 1-9
In Situ Measurement of High-Frequency Magnetic Field Produced by Electric Heaters in Atomic Sensors
In this study, an in situ measurement method for the high-frequency magnetic field (HFMF) produced by electric heaters in atomic sensors has been proposed for the first time. It is hypothesized and demonstrated that the HFMF generated by electric heaters can be equated to a modulation field that excites atomic spin coherence, from theory and experiment, respectively. Specifically, the spin polarization of atoms in response to the HFMF generated by electric heaters is modeled skillfully using a rotating frame based on the establishment of an optically detected magnetic resonance (ODMR) atomic magnetometer. By combining different equations of spin polarization through systematically varying the parameters of bias and modulation fields, the triaxial amplitudes of the HFMF can be rapidly obtained which are$ (42.26~\pm ~0.12) $ nT,$ (79.28~\pm ~0.04)$ nT, and$ (184.98~\pm ~1.98)$ nT, respectively. The corresponding coefficients of variation are 0.28%, 0.05%, and 1.07%, respectively. The agreement observed between experimental and simulation results provides robust confirmation of the reliability and utility of the method put forth in this study. Our method presented here implements the in situ measurement of HFMF generated by electric heaters, avoiding positional errors arising from non-in situ measurement methods, which has the potential for miniaturized and low-cost atomic sensor applications.- 15 July 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 73 (00189456) , 1-9
In Situ Measurement of High-Frequency Magnetic Field Produced by Electric Heaters in Atomic Sensors
In this study, an in situ measurement method for the high-frequency magnetic field (HFMF) produced by electric heaters in atomic sensors has been proposed for the first time. It is hypothesized and demonstrated that the HFMF generated by electric heaters can be equated to a modulation field that excites atomic spin coherence, from theory and experiment, respectively. Specifically, the spin polarization of atoms in response to the HFMF generated by electric heaters is modeled skillfully using a rotating frame based on the establishment of an optically detected magnetic resonance (ODMR) atomic magnetometer. By combining different equations of spin polarization through systematically varying the parameters of bias and modulation fields, the triaxial amplitudes of the HFMF can be rapidly obtained which are$ (42.26~\pm ~0.12) $ nT,$ (79.28~\pm ~0.04)$ nT, and$ (184.98~\pm ~1.98)$ nT, respectively. The corresponding coefficients of variation are 0.28%, 0.05%, and 1.07%, respectively. The agreement observed between experimental and simulation results provides robust confirmation of the reliability and utility of the method put forth in this study. Our method presented here implements the in situ measurement of HFMF generated by electric heaters, avoiding positional errors arising from non-in situ measurement methods, which has the potential for miniaturized and low-cost atomic sensor applications.- 21 August 2023
- Published by Elsevier in Measurement
- Vol. 221
Fast measurement of spin-exchange relaxation in the range of earth-scale magnetic field
- 21 August 2023
- Published by Elsevier in Measurement
- Vol. 221
Fast measurement of spin-exchange relaxation in the range of earth-scale magnetic field