LXLiangyu Xia

Liangyu Xia

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Liangyu Xia has a total of 63 co-authors. Here are the top co-authors by number of shared publications:

  • Ling Qiu

    Department of Laboratory Medicine, Peking Union Medical College Hospital, Chinese Academy of Medical Sciences & Peking Union Medical College, Beijing, China

    4 shared publications
  • Songlin Yu

    Department of Laboratory Medicine, Peking Union Medical College Hospital Chinese Academy of Medical Sciences Beijing China

    3 shared publications
  • Danchen Wang

    Department of Laboratory Medicine, Peking Union Medical College Hospital Chinese Academy of Medical Sciences Beijing China

    2 shared publications
  • Kui Zhang

    Department of Laboratory Medicine, Peking Union Medical College Hospital, Peking Union Medical College and Chinese Academy of Medical Science, Beijing, China

    2 shared publications
  • Li Liu

    Department of Laboratory Medicine, Peking Union Medical College Hospital, Peking Union Medical College and Chinese Academy of Medical Science, Beijing, People's Republic of China

    2 shared publications
  • Ling Qiu

    Department of Laboratory Medicine, Peking Union Medical College Hospital, Chinese Academy of Medical Sciences, Beijing, China

    2 shared publications

Latest Publications

  • Open Access

    Calcium Dobesilate Interference in Two Urinary Total Protein Detection Methods

    by Zheng Mingqi, Ma Xiaoli, Yu Songlin, Danchen Wang, Zhang Qi, Guo Xiuzhi, Xu Jingrong, Zhang Kui, Qiu Ling, Xia Liangyu

    Background: This study aimed to determine the potential interference of calcium dobesilate in two urinary total protein detection methods. Methods: Urine samples from patients receiving calcium dobesilate were collected, and drug concentrations were quantified using liquid chromatography‐tandem mass spectrometry. Paired‐difference testing was used to assess if calcium dobesilate interfered with the total protein concentration measurement. The interference effect of calcium dobesilate on the detection method was evaluated using dose–effect experiments. Results: In total, 22 24‐h urine samples and 50 spot urine samples were collected. The calcium dobesilate concentrations ranged from 76 to 738 mg/L (median: 243 [161, 328] mg/L) and 60–2236 mg/L (median: 370 [195, 667] mg/L) in the 24‐h and spot urine samples, respectively. Paired‐difference testing showed that the total protein results deviated by 0.8%–12.1% and 13.0%–286.4% with the pyrogallol red‐molybdate and benzethonium chloride methods, respectively, when the calcium dobesilate concentration was 4500 mg/L. The dose–response experiment with the benzethonium chloride method demonstrated a “J‐shaped” effect; negative interference on the total protein concentration occurred at low and medium calcium dobesilate concentrations, but positive interference occurred at high calcium dobesilate concentrations. Conclusions: Calcium dobesilate did not significantly interfere with the pyrogallol red‐molybdate method but did significantly interfere with the benzethonium chloride method. The direction and degree of interference were related to the urinary protein and drug concentrations. Discontinuing calcium dobesilate for 1–2 days before obtaining a urine sample for total protein detection is recommended.

  • Open Access

    Real-world study: Assessing the impact of hemolysis on 48 biochemical and immunological analytes through big data analysis and its feasibility validation

    by Chaochao Ma, Xiaoqi Li, Wei Luo, Lian Hou, Dandan Sun, Li Liu, Xin Liu, Ying Zhang, Jingrong Xu, Ling Qiu, et al.

    Background: This research utilizes clinical laboratory real-world data to explore the influence of in vitro hemolysis on 48 biochemical and immunological analytes, aiming to propose and validate the methods and tools based on big data for analysis of the impact of hemolysis on laboratory analytes. Methods: This research initially employs univariate analysis to display the levels and distribution of 48 analytes across different H-index groups. Subsequently, it utilizes quantile regression models to analyze the impact of hemolysis on laboratory analytes, adjusting for age, gender, patient type, and PVD, with the magnitude of impact described using β values and 95% CIs, visualized through error bar graphs. Finally, the study compares its results with those obtained from homogenized experimental research using the same testing platforms and hemolysis assessment methods, validating the feasibility of conducting research based on big data. Results: Adjusting for gender, age, patient type, and PVD, hemolysis showed a significant positive interference on ALT, Alb, TBil, GGT, AST, CK, LD, K, P, Mg, and FFA(P < 0.001)., and a significant negative interference on DBil, Na, Cl, TCO2, and Cr (P < 0.001). High hemolysis levels also negatively interfere UA, PA, and GA. No consistent pattern of significance was observed for other analytes. Our multivariate analysis, when compared to experimental data, revealed a 93.0% concordance, with discrepancies noted in GGT, ALP, and RF. Conclusions: The impact of hemolysis on laboratory analytes can be effectively evaluated through comprehensive big data analysis, demonstrating a level of consistency comparable to that of homogeneous experimental research.


  • Open Access

    From interference to insight: pseudo-lipidemia led to the diagnosis of Waldenström macroglobulinemia

    by Danchen Wang, Pengchang Li, Wei Su, Li’aN Hou, Jianhua Han, Ying Zhang, Li Liu, Danni Mu, Liangyu Xia, Ling Qiu

    Waldenström macroglobulinemia (WM) is a rare hematological disorder with an annual incidence of about 3 per million. Its clinical manifestations are diverse and non - specific, and approximately 30% of patients are asymptomatic, making early diagnosis challenging. This paper reports a 73-year-old female who was admitted to the hospital due to atrial fibrillation. During a physical examination several years before the hospitalization, an elevated CA19-9 was detected, but the cause remained unclear after multiple outpatient visits. During cardiac markers testing, an abnormal serum index (HIL) suggested a lipidemic sample, yet the sample appeared clear visually. A Sia water test showed positive result, and subsequent serum protein electrophoresis confirmed the presence of M protein, leading to the diagnosis of WM. During the treatment in the following 6 years, it was found that the levels of CA19-9 and IgM fluctuated in parallel. Abnormal lipid indices and albumin-globulin ratio can provide important clues for the diagnosis of WM, but they may be overlooked in clinical practice. When the total protein increases with normal or decreased albumin levels, a reflex test of serum protein electrophoresis can help with early diagnosis. This case shows that understanding and using interference information in laboratory tests can assist in the diagnosis of WM.


  • Open Access

    Comparison of Direct and Extraction Immunoassay Methods With Liquid Chromatography-Tandem Mass Spectrometry Measurement of Urinary Free Cortisol for the Diagnosis of Cushing’s Syndrome

    by Danni Mu, Jiadan Fang, Songlin Yu, Yichen Ma, Jin Cheng, Yingying Hu, Ailing Song, Fang Zhao, Qi Zhang, Zhihong Qi, et al.

    Danni Mu, B.S., Jiadan Fang, M.S., Songlin Yu, M.S., Yichen Ma, B.S., Jin Cheng, M.S., Yingying Hu, B.S., Ailing Song, B.S., Fang Zhao, B.S., Qi Zhang, M.S., Zhihong Qi, M.S., Kui Zhang, B.S., Liangyu Xia, M.S., Ling Qiu, M.S., Huijuan Zhu, Ph.D., and Xinqi Cheng, Ph.D.. Ann Lab Med 2024;44:29-37. https://doi.org/10.3343/alm.2024.44.1.29


  • Metabolic profiling in early pregnancy and associated factors of folate supplementation: A cross-sectional study

    by Rui Zhao, Zhuoling An, Yuan Sun, Liangyu Xia, Ling Qiu, Aimin Yao, Yanping Liu, Lihong Liu


  • Open Access

    Reference Intervals for Thyroid-Associated Hormones and the Prevalence of Thyroid Diseases in the Chinese Population

    by Yutong Zou, Danchen Wang, Xinqi Cheng, Chaochao Ma, Songbai Lin, Yingying Hu, Songlin Yu, Liangyu Xia, Honglei Li, Yicong Yin, et al.

    Yutong Zou, B.S., Danchen Wang, M.S., Xinqi Cheng, M.S., Chaochao Ma, B.S., Songbai Lin, Ph.D., Yingying Hu, B.S., Songlin Yu, M.S., Liangyu Xia, M.S., Honglei Li, B.S., Yicong Yin, M.S., Huaicheng Liu, B.S., Dianxi Zhang, B.S., Kui Zhang, B.S., Xiaolan Lian, Ph.D., Tengda Xu, Ph.D., and Ling Qiu, M.S.. Ann Lab Med 2021;41:77-85. https://doi.org/10.3343/alm.2021.41.1.77


  • Effects of calcium dobesilate (CaD) interference on serum creatinine measurements: a national External Quality Assessment (EQA)-based educational survey of drug-laboratory test interactions

    by Tianjiao Zhang, Xiuzhi Guo, Li’AN Hou, Haijian Zhao, Rong Ma, Liangyu Xia, Honglei Li, Tingting You, Ling Qiu, Chuanbao Zhang

    Objectives: Drug-laboratory test interactions (DLTIs) are one of the major sources of laboratory errors. Calcium dobesilate (CaD) interference on serum creatinine testing is a widespread problem that has long been ignored in China. A national EQA-based survey was launched to investigate the current status of CaD interference on creatinine routine methods used in China and enhance the education of CaD interference in clinical laboratories. Methods: A descriptive survey was developed to characterize the status quo of Chinese laboratory professionals’ cognition to CaD interference. Four of survey samples which were spiked with/without interference additive were shipped to 175 participant laboratories. The target reference values from a reference measurement procedure were compared against the results from participating laboratories to evaluate the CaD interference on serum creatinine measurements using enzymatic method or Jaffé method. Results: The lack of knowledge of DLTIs and the barriers to collect information from pharmacological and laboratory data systems had become the main problems on implementing DLTIs education in China. A significant negative influence of CaD on enzymatic method was observed regardless of measurement platforms. Jaffé method was generally free from interaction with CaD but showed poor precision and accuracy at low creatinine concentrations. Conclusions: More efforts should be made to enhance the education of DLTIs in clinical laboratories in China.