Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Hanieh Bazyar has a total of 51 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Electro‐Active Polymer Actuated Microfiltration Membranes: Design, Performance, and Particle Dynamics

    by Irem Gurbuz, Hanieh Bazyar, Andres Hunt

    Membranes used in water treatment are prone to fouling, leading to flux decline, increased operational costs, and reduced lifespan. Conventional antifouling methods, such as chemical cleaning and backwashing, are effective but have significant drawbacks. This study introduces active polymeric microfiltration membranes with embedded self‐cleaning functionality by printing electro‐active polymer (EAP) actuators on porous PVDF and PTFE membranes. The design parameters for the membrane‐actuators, including membrane material selection, actuator placement, and active layer thickness are investigated. During membrane excitation, resonance frequencies/modes, surface displacements, velocities, and accelerations are detected with laser Doppler vibrometer (PSV‐400). By leveraging the electrostrictive properties of the P(VDF–TrFE–CTFE) terpolymer, the actuators generate out‐of‐plane surface vibrations, achieving average surface accelerations of up to 75 m s −2 (600 V, 4548 Hz) and local surface accelerations up to 255 m s −2 (600 V, 6560 Hz). Particle manipulation in air and aqueous media is respectively tested with randomly distributed metal alloy balls (200 µm diameter) and Iriodin 153 Flash Pearl suspension (1 wt%) on the active membranes. The dry metal alloy balls show strong resonant dislocations near 3500 Hz and 6700 Hz frequencies, while Iriodin 153 Flash Pearl particles (20–100 µm diameter) are visibly mobilized and redistributed at ≈3100 and 5400 Hz frequencies. The results indicate that mechanical agitation of filtration membranes via embedded actuation is a viable method for foulant mobilization, and will be further investigated for fouling mitigation in membrane filtration technologies.

  • Open Access

    Multifunctional poly(ionic liquid)/graphitic carbon nitride membranes: visible light-driven photodegradation coupled with antifouling properties

    by Hannah Schimke, Baris Kumru, Hanieh Bazyar

    Poly(ionic liquid) membranes with carbon nitride nanoparticle incorporation exhibit advanced properties.


  • Open Access

    3D-Printed Microfiltration Membranes via Dual-Wavelength Microstereolithography

    by Hanieh Bazyar, Shang-Che Wu, Irem Gurbuz, Athanasios Papageorgiou, Wesley van Vliet, Alexander Kostenko, Jimmy G. Jean, Guillaume Broggi, Baris Caglar

    A new and sustainable membrane manufacturing method is 3D printing, which reduces the number of fabrication steps, waste production, and the corresponding CO2 emissions. It further enables fabricating membranes with well-defined pore size, shape, and configuration. Here, we study 3D printing of microfiltration membranes using a novel dual-wavelength microstereolithography method. Via the gradient descent method, we are able to calculate and control a printable membrane with micrometer precision, enabling the possibility of printing membranes directly. Hydrophilic porous membranes with cylindrical microscale pores (≈10 μm in diameter) are printed from polyethylene glycol diacrylate (PEGDA). Membrane printing procedure and postprocessing steps are thoroughly investigated to print consistent membranes with uniform thickness. The membranes are fully characterized using SEM, FTIR, contact angle, and surface roughness measurements. The pure water permeability and separation performance of the 3D-printed membrane are further investigated and compared with those of commercial hydrophilic PTFE membranes. The 3D-printed membranes show similar permeability values to those of commercial membranes and could successfully separate oil droplets from oil-in-water emulsions. The membranes' permeability is further predicted using a 1D tube model and numerical modeling. The effect of material's property (e.g., swelling) and pore deformation during pressurization are studied to understand the discrepancy between the calculated and the experimental permeability values. The results provide valuable insights into the permeability prediction of 3D-printed membranes and the corresponding design optimization.


  • Inkjet-printed microgel-based etalon sensor

    by G. Kontaxi, T. J. Lugtmeijer, M. J. Serpe, H. Bazyar

    Stimuli-responsive microgel-based etalons are promising optical and bio-sensors. These sensors play a pivotal role in modern healthcare by enabling rapid biomolecule detection, contributing to organ-on-chip applications and early disease diagnosis. This study investigates the suitability of poly(N-isopropylacrylamide) (pNIPAm)-based microgels for inkjet printing, focusing on optimizing their properties for effective deposition. Key parameters, including surface tension, viscosity, and particle size, are characterized to ensure compatibility with inkjet-printing requirements. The addition of surfactants tunes the suspensions’ properties to be in line with the requirements of inkjet printing. Jetting of pNIPAm-based microgels on gold-coated substrates forms a cohesive drop in a range of a few millimeters. Optical and scanning electron microscopy confirm the formation of a uniform microgel layer. The optical reflectance spectroscopy results indicate that inkjet-printed microgel-based etalons can effectively respond to changes in temperature and glucose concentration. In-liquid atomic force microscopy demonstrates the swelling dynamics of the microgels in different glucose concentrations, shedding light on their response dynamics. Our work demonstrates, for the first time, the feasibility of printing microgels in a controlled way, fabricating biocompatible inkjet-printed microgel-based etalon sensors with precise dimensions. The size precision and the sensitive monitoring capabilities of biomolecules hold great promise for in situ and continuous sensing in a wide range of biological and organ-on-chip applications.


  • Open Access

    Etalon@lateral flow strip for integrated separation-sensing microfluidic platforms

    by Mengmeng Zhang, Arjo J. Loeve, Michael J. Serpe, Hanieh Bazyar


  • Open Access

    Graphitic Carbon Nitride Embedded Bio-Based Acrylic Films as Surface Active Photocatalysts

    by Chuyue Lu, Niklas Lorenz, Hanieh Bazyar, Giulio Malucelli, Baris Kumru

    Soybean oil, a sustainable and renewable resource, has gained increasing industrial relevance through its derivatives, such as acrylated soybean oil, which is now produced at significant commercial scales. In contrast, graphitic carbon nitride (g-CN), a metal-free polymeric semiconductor, remains unexplored in industrial polymer systems. This study explores the integration of graphitic carbon nitride into bio-based acrylic resins using a rapid UV-curing process at a belt speed of 1 m/min. The resulting nanocomposite films, incorporating 10% nanoparticle loading and with an average thickness of 200 μm, demonstrate promising photocatalytic properties with a bandgap of 2.7 eV. The photocatalytic performance of these films is thoroughly evaluated via dye degradation experiments, revealing enhanced surface-driven activity, particularly in alcohol-based media. While the hydrophobic nature of the films limits dye removal in aqueous environments (25% removal efficiency in 5 h), complete photodegradation of methylene blue is achieved in alcohol within 5 h. Moreover, the films maintain their photocatalytic efficiency over five cycles with no significant performance deprivation.


  • Open Access

    Microgel-based etalon membranes: Characterization and properties

    by G. Kontaxi, G. Wensink, P. M. Sberna, M. Rücker, V. Garbin, M. J. Serpe, H. Bazyar

    We introduce Microgel-based Etalon Membranes (MEMs), based on the combination of stimuli-responsive microgels with an etalon, which is an optical device consisting of two reflecting plates and is used to filter specific wavelengths of light. The microgels are sandwiched between two reflective layers and, in response to a stimulus (e.g., temperature, pH, or biomarker concentration), swell or de-swell, thereby changing the distance between the two reflective layers and generating multiple peaks in the reflectance spectra. This property gives a MEM the unique capability of simultaneous separation and tunable responses to environmental changes and/or biomarker concentrations. We propose a design based on gold layers on a silicon nitride wafer membrane. Our comprehensive characterization, employing permeability experiments, in situ optical reflectance spectroscopy, in-liquid atomic force microscopy (AFM) analysis, and captive bubble contact angle measurements, elucidates the dynamic response of MEM to pH, temperature, and glucose stimuli and the corresponding effect of microgel swelling/de-swelling on the membrane properties, e.g., permeability. The AFM results confirm the dynamic changes of the microgel layer’s thickness on the membrane surface in response to the stimuli. Although the microgel’s swelling/de-swelling influences the effective pore radius, the decrease in the membrane’s permeance is limited to less than 10%. In the swollen state of the microgels, the etalon membranes show a prominent hydrophilic behavior, while they become less hydrophilic in the microgels’ de-swollen state. This work introduces MEM and provides novel insights into their behavior. The fundamental understanding that we reveal opens the way to applications ranging from point-of-care testing to continuous environmental monitoring.


  • Open Access

    Acoustophoresis of monodisperse oil droplets in water: Effect of symmetry breaking and non-resonance operation on oil trapping behavior

    by H. Bazyar, M. H. Kandemir, J. Peper, M. A. B. Andrade, A. L. Bernassau, K. Schroën, R. G. H. Lammertink

    Acoustic manipulation of particles in microchannels has recently gained much attention. Ultrasonic standing wave (USW) separation of oil droplets or particles is an established technology for microscale applications. Acoustofluidic devices are normally operated at optimized conditions, namely, resonant frequency, to minimize power consumption. It has been recently shown that symmetry breaking is needed to obtain efficient conditions for acoustic particle trapping. In this work, we study the acoustophoretic behavior of monodisperse oil droplets (silicone oil and hexadecane) in water in the microfluidic chip operating at a non-resonant frequency and an off-center placement of the transducer. Finite element-based computer simulations are further performed to investigate the influence of these conditions on the acoustic pressure distribution and oil trapping behavior. Via investigating the Gor’kov potential, we obtained an overlap between the trapping patterns obtained in experiments and simulations. We demonstrate that an off-center placement of the transducer and driving the transducer at a non-resonant frequency can still lead to predictable behavior of particles in acoustofluidics. This is relevant to applications in which the theoretical resonant frequency cannot be achieved, e.g., manipulation of biological matter within living tissues.