HKHuidong Kim

Huidong Kim

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Huidong Kim has a total of 73 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Strontium 1 S 0 → 1 P 1 transition frequency measurements assisted by a photonic grating chip

    by Jaewhan Lee, Hyun Gyung Lee, Won-Kyu Lee, Huidong Kim, Dohyeon Kwon, Sang-Bum Lee, Meungho Seo, Taeg Yong Kwon, Sangwon Seo, Hyun-Gue Hong, et al.

    We measure the absolute frequency of the 1 S 0 → 1 P 1 transition in strontium using two methods: fluorescence spectroscopy of a thermal atomic beam source from a compact low-power oven and velocity measurements of a slow atomic beam from a two-dimensional grating magneto-optical trap (2D gMOT). The measurements for both methods are performed in the same ultra-high vacuum chamber containing a diffraction grating chip which is placed below the strontium atoms that are being interrogated. The first method uses a probe laser beam incident on the grating chip such that the grating acts as an end mirror, with the first-order diffracted beam providing a retro-reflected probe beam. The counter-propagating laser beams traverse an atomic beam emitted from an oven, enabling spatially resolved fluorescence spectroscopy through CCD imaging and hyperfine-constrained multi-isotope fitting. The second method relies on a large profile cooling laser beam normally incident onto the grating chip which laser cools strontium atoms for a slow atomic beam source. The velocity of the atoms exiting the 2D gMOT is measured as a function of the laser detuning and intensity from which the resonance frequency can be estimated. The two methods are consistent within their quoted uncertainties. Using three datasets based on retro-beam spectroscopy measurements, and one dataset using slow atom beam velocity measurements, we determine the 1 S 0 → 1 P 1 transition frequency to be 650.503 815 ( 5 )   THz . Our result provides a re-evaluation of this 461 nm transition demonstrated on a compact laser cooling apparatus based on a diffraction grating platform.


  • Open Access

    A High-frequency Geodetic VLBI Experiment for Optical Clock Comparison

    by Monia Negusini, Myoung-Sun Heo, Cecilia Clivati, Shuangjing Xu, Roberto Ricci, Taehyun Jung, Buseung Cho, Matteo Stagni, Claudio Bortolotti, Giuseppe Maccaferri, et al.

    An intercontinental metrological clock comparison between Italy and the Republic of Korea was performed by means of geodetic K -band VLBI observations. The comparison involved the hydrogen masers (H-masers) used at Medicina and Sejong radio telescopes. The same clocks were simultaneously compared by a satellite link and by high-precision optical clocks maintained at the National Metrology Institutes, KRISS in Korea and INRIM in Italy, and delivered to VLBI antennas via optical fiber. The H-masers frequency difference was estimated by extrapolating the clock rate from VLBI data using two geodetic VLBI software. This was subsequently compared with clock differences derived by satellite link and by local optical clocks. Results obtained with different approaches were in agreement at the level of 10 −15 s s −1 . This pilot study demonstrates that standard high-frequency ( K -band) geodetic VLBI campaigns could be a viable approach to conduct intercontinental clock comparisons, now only possible via satellite links. This uncertainty can be reduced thanks to the planned installation of new-generation, broadband, high-frequency receivers on the involved telescopes. K / Q / W -band geodetic observations will allow an improvement of the accuracy of the resulting group delays through broad bandwidth synthesis from 20 to 100 GHz. Furthermore, the Frequency Phase Transfer method will also be explored together with the use of PCAL systems installed at the radio telescopes to improve phase stability and thus allow a better estimation of the station clock parameters.


  • Open Access

    Evaluation of the relativistic redshift in frequency standards at KRISS

    by Jisun Lee, Jay Hyoun Kwon, Chang Yong Park, Huidong Kim, In-Mook Choi, Jin Wan Chung, Won-Kyu Lee

    Relativistic redshift correction should be accurately considered in frequency comparisons between frequency standards. In this study, we evaluated the relativistic redshift at Korea Research Institute of Standards and Science (KRISS) using three different methods, depending on whether the approach was traditional or modern or whether the geopotential model was global or local. The results of the three methods agreed well with one another, and the height of an Yb optical lattice clock (KRISS-Yb1) was determined to be 75.15 m with an uncertainty of 0.04 m with respect to the conventionally adopted equipotential surface W 0 CGPM , the value of which is defined to be 62 636 856.0 m2s−2. Accordingly, the relativistic redshift of KRISS-Yb1 was evaluated to be 8.193(4) × 10−15. These data are applicable to the frequency standards at KRISS, one of which regularly participates in the calibration of the International Atomic Time.


  • Open Access

    Characteristics of a real-time ensemble time scale corrected by the KRISS-PSFS using a reduced Kalman filter (Kred) algorithm

    by Ho Seong Lee, Taeg Yong Kwon, Sang Eon Park, Young Kyu Lee, Sung-Hoon Yang, Dai-Hyuk Yu, Myoung-Sun Heo, Huidong Kim, Chang Yong Park, Won-Kyu Lee

    An ensemble time, which is indicated by TA (temps atomique, in French), was generated every minute by combining four active hydrogen masers with the reduced Kalman filter (Kred) algorithm. The TA frequency was averaged over 12 h and then the mean frequency was steered to the primary and secondary frequency standards developed by KRISS with a micro-phase stepper (MPS). The steered and physically realized TA frequency is called KRISS ensemble time (KET). We investigated the frequency-state estimate outputted from the Kred algorithm and the control signal applied to the MPS, according to the abnormal temperature change of the room where the hydrogen masers were placed. When the frequency of the TA was corrected by the KRISS-F1, the Allan deviation of KET was 1.72 × 10−15 at the average time τ = 1 d, and the variation of [UTC–KET] was stable within 2 ns for 75 d.


  • 10.1063/5.0123971.1

    by Won-Kyu Lee, Myoung-Sun Heo, Dai-Hyuk Yu, Huidong Kim

    We developed a shutter driven by a solenoid to switch on/off the atomic beam of optical lattice clocks developed at KRISS [C. Y. Park et al., Metrologia 50, 119 (2013), S. Lee et al., New J. Phys. 18, 033030 (2016), H. Kim et al., Jpn. J. Appl. Phys. 56, 050302 (2017), and H. Kim et al., Metrologia 58, 055007 (2021)]. The shutter design was focused on long lifetime and compatibility with an ultra-high vacuum (UHV) environment. Thus, the solenoid was designed to be easily installed and removed from the air-side of a CF flange of the shutter. The flag in the vacuum-side moves only with the simple spring action of a sheet of a metal plate without any frictional movement of mechanical parts. All parts in the vacuum-side were made of metals (stainless steel and pure iron) to be baked over the temperature of 200 °C for UHV. The flag head of the shutter displaces up to 10 mm (5 mm) with a response time of 50 (30 ms) and 80 ms (10 ms) for the opening-action and the closing-action, respectively. The lifetime was tested up to 6 × 106 cycles with no performance degradation. We expect the actual lifetime to be much longer than this by virtue of its friction-free design.

  • 10.1063/5.0123971.3

    by Won-Kyu Lee, Myoung-Sun Heo, Dai-Hyuk Yu, Huidong Kim

    We developed a shutter driven by a solenoid to switch on/off the atomic beam of optical lattice clocks developed at KRISS [C. Y. Park et al., Metrologia 50, 119 (2013), S. Lee et al., New J. Phys. 18, 033030 (2016), H. Kim et al., Jpn. J. Appl. Phys. 56, 050302 (2017), and H. Kim et al., Metrologia 58, 055007 (2021)]. The shutter design was focused on long lifetime and compatibility with an ultra-high vacuum (UHV) environment. Thus, the solenoid was designed to be easily installed and removed from the air-side of a CF flange of the shutter. The flag in the vacuum-side moves only with the simple spring action of a sheet of a metal plate without any frictional movement of mechanical parts. All parts in the vacuum-side were made of metals (stainless steel and pure iron) to be baked over the temperature of 200 °C for UHV. The flag head of the shutter displaces up to 10 mm (5 mm) with a response time of 50 (30 ms) and 80 ms (10 ms) for the opening-action and the closing-action, respectively. The lifetime was tested up to 6 × 106 cycles with no performance degradation. We expect the actual lifetime to be much longer than this by virtue of its friction-free design.

  • 10.1063/5.0123971.2

    by Won-Kyu Lee, Myoung-Sun Heo, Dai-Hyuk Yu, Huidong Kim

    We developed a shutter driven by a solenoid to switch on/off the atomic beam of optical lattice clocks developed at KRISS [C. Y. Park et al., Metrologia 50, 119 (2013), S. Lee et al., New J. Phys. 18, 033030 (2016), H. Kim et al., Jpn. J. Appl. Phys. 56, 050302 (2017), and H. Kim et al., Metrologia 58, 055007 (2021)]. The shutter design was focused on long lifetime and compatibility with an ultra-high vacuum (UHV) environment. Thus, the solenoid was designed to be easily installed and removed from the air-side of a CF flange of the shutter. The flag in the vacuum-side moves only with the simple spring action of a sheet of a metal plate without any frictional movement of mechanical parts. All parts in the vacuum-side were made of metals (stainless steel and pure iron) to be baked over the temperature of 200 °C for UHV. The flag head of the shutter displaces up to 10 mm (5 mm) with a response time of 50 (30 ms) and 80 ms (10 ms) for the opening-action and the closing-action, respectively. The lifetime was tested up to 6 × 106 cycles with no performance degradation. We expect the actual lifetime to be much longer than this by virtue of its friction-free design.

  • Ultra-high vacuum compatible full metal atom beam shutter for optical lattice clocks

    by Chang Yong Park, Won-Kyu Lee, Myoung-Sun Heo, Dai-Hyuk Yu, Huidong Kim

    We developed a shutter driven by a solenoid to switch on/off the atomic beam of optical lattice clocks developed at KRISS [C. Y. Park et al., Metrologia 50, 119 (2013), S. Lee et al., New J. Phys. 18, 033030 (2016), H. Kim et al., Jpn. J. Appl. Phys. 56, 050302 (2017), and H. Kim et al., Metrologia 58, 055007 (2021)]. The shutter design was focused on long lifetime and compatibility with an ultra-high vacuum (UHV) environment. Thus, the solenoid was designed to be easily installed and removed from the air-side of a CF flange of the shutter. The flag in the vacuum-side moves only with the simple spring action of a sheet of a metal plate without any frictional movement of mechanical parts. All parts in the vacuum-side were made of metals (stainless steel and pure iron) to be baked over the temperature of 200 °C for UHV. The flag head of the shutter displaces up to 10 mm (5 mm) with a response time of 50 (30 ms) and 80 ms (10 ms) for the opening-action and the closing-action, respectively. The lifetime was tested up to 6 × 106 cycles with no performance degradation. We expect the actual lifetime to be much longer than this by virtue of its friction-free design.


  • Open Access

    Evaluation of the blackbody radiation shift of an Yb optical lattice clock at KRISS

    by Myoung-Sun Heo, Huidong Kim, Dai-Hyuk Yu, Won-Kyu Lee, Chang Yong Park

    As optical clocks are improved to reach the frequency uncertainty below the 10−17 level, the frequency shift due to the blackbody radiation (BBR) has been one of the major systematic effects hindering further improvement. To evaluate the BBR shift of an Yb optical lattice clock at KRISS, we installed an in-vacuum BBR shield and made radiation thermometry using a black-coated-sphere thermal probe. After we quantitatively measured the conduction loss of the thermal probe and the effects of all the external radiation sources, we determined the temperature at the atom trap site with an uncertainty of 13 mK, which corresponds to an uncertainty of 0.22 mHz in the clock frequency (a fractional frequency of 4.2 × 10−19). The total uncertainty of the BBR shift including the atomic response is 9.5 × 10−19.


  • Open Access

    Absolute frequency measurement of the 171Yb optical lattice clock at KRISS using TAI for over a year

    by Huidong Kim, Myoung-Sun Heo, Chang Yong Park, Dai-Hyuk Yu, Won-Kyu Lee

    We report a measurement of the absolute frequency of the 1S0–3P0 transition in the 171Yb optical lattice clock at KRISS (KRISS-Yb1) for 14 months, which was referenced to the SI second by primary and secondary standards worldwide via International Atomic Time. The determined absolute frequency is 518 295 836 590 863.75(14) Hz with the relative frequency uncertainty of 2.6 × 10−16, which agrees well with other reports. This result is expected to contribute to the future update of the CIPM recommendation frequency of the secondary frequency standards.