HHHirokazu Hashizume

Hirokazu Hashizume

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Hirokazu Hashizume has a total of 52 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Development of Electroformed X-Ray Optics Bridging Synchrotron Radiation Technology and Space Astronomy

    by Ryuto Fujii, Koki Sakuta, Kazuki Ampuku, Yusuke Yoshida, Makoto Yoshihara, Ayumu Takigawa, Keitoku Yoshihira, Tetsuo Kano, Naoki Ishida, Noriyuki Narukage, et al.

    We have developed X-ray telescope mirrors using our original electroforming replication technique, which was established through the fabrication of millimeter-aperture, ultra-short-focal-length nanofocusing mirrors used in synchrotron X-ray microscopy. In this paper, we present for the first time the detailed results of X-ray illumination tests performed both for a 60 mm diameter, full-circumference, double-reflection monolithic electroformed nickel mirror and for the Mirror Module Assembly (MMA) incorporating it. The experiments were performed at SPring-8 beamline BL29XUL, which has a 1 km beamline length. To simulate the parallel X-ray beam from celestial sources, we constructed and utilized a dedicated evaluation system, the High-Brilliance X-ray Kilometer-long Large-Area Expanded-beam Evaluation System (HBX-KLAEES). Thanks to the high photon flux and the virtually point-like source with a very small diverging angle provided by HBX-KLAEES, we were able to evaluate the imaging performance with high fidelity, resolving both the sharp core and the large-angle components of the Point Spread Function. The results demonstrated an extremely sharp core with a Full Width at Half Maximum of 0 . ″ 7 and a Half Power Diameter of 14″ even after integration into the MMA. Furthermore, a positive correlation was found between the angular resolution and the axial direction figure error of both the primary and secondary sections, indicating that the axial figure error contributes to image degradation. Based on these achievements, the MMA incorporating this mirror was selected as one of the hard X-ray optics for the FOXSI-4 sounding rocket experiment, which performs high-resolution soft and hard X-ray imaging spectroscopy of solar flares, and was successfully launched. These results pave the way for further improvements in angular resolution and for the development of high-resolution, ultra-short focal length X-ray optics applicable to small satellites including CubeSats.


  • Open Access

    Development of Electroformed X-ray Optics Bridging Synchrotron Technology and Space Astronomy

    by Ryuto Fujii, Koki Sakuta, Kazuki Ampuku, Yusuke Yoshida, Makoto Yoshihara, Ayumu Takigawa, Keitoku Yoshihira, Tetsuo Kano, Naoki Ishida, Noriyuki Narukage, et al.

    We have developed X-ray telescope mirrors using an original electroforming replication technique established through the fabrication of millimeter-aperture, ultra-short-focal-length nanofocusing mirrors for synchrotron X-ray microscopy. This paper presents detailed results of X-ray illumination tests of a 60-mm-diameter, full-circumference, double-reflection monolithic electroformed nickel mirror and its Mirror Module Assembly (MMA). The experiments were conducted at the 1-km beamline BL29XUL at SPring-8. To simulate a parallel X-ray beam from celestial sources, we constructed a dedicated evaluation system, the High-Brilliance X-ray Kilometer-long Large-Area Expanded-beam Evaluation System (HBX-KLAEES). Owing to the high photon flux and the quasi-point-like source with a small divergence provided by HBX-KLAEES, the imaging performance was evaluated with high fidelity, resolving both the sharp core and large-angle components of the Point Spread Function (PSF). The results show an extremely sharp core with a Full Width at Half Maximum (FWHM) of 0.7 arcsec and a Half Power Diameter (HPD) of 14 arcsec, even after integration into the MMA. In addition, a positive correlation was found between angular resolution and axial figure error in both the primary and secondary mirror sections, indicating that axial figure errors contribute to image degradation. Based on these results, the MMA was selected as one of the hard X-ray optics for the FOXSI-4 sounding rocket experiment, which performs high-resolution soft and hard X-ray imaging spectroscopy of solar flares and was successfully launched. These results demonstrate the potential for further improvements in angular resolution and the development of high-resolution, ultra-short focal length X-ray optics for small satellites, including CubeSats.

  • Open Access

    Efficient and precise fabrication of Wolter type-I x-ray mirrors via nickel electroforming replication using quartz glass mandrels

    by Gota Yamaguchi, Yusuke Matsuzawa, Takehiro Kume, Yoichi Imamura, Hiroaki Miyashita, Akinari Ito, Koki Sakuta, Kazuki Ampuku, Ryuto Fujii, Kentaro Hiraguri, et al.

    This study presents an approach for fabricating Wolter type-I mirrors for x-ray telescopes using a nickel electroforming replication process with quartz glass mandrels. The proposed method addresses the challenges encountered in conventional fabrication techniques, which involve using electroless nickel-coated aluminum mandrels that are susceptible to corrosion and thermal deformation. Quartz glass mandrels offer excellent chemical, thermal, and mechanical stability, enabling the efficient production of high-performance mirrors. Wolter type-I mirrors for telescopes possess a large aperture that collects x-ray photons from the universe. However, previous nickel electroforming replication processes using quartz glass mandrels have challenges in fabricating large mirrors, particularly due to bubble pit formation during nickel shell development. In this study, we introduced an efficient pitting inhibition technique via vacuum degassing. This technique facilitates the precise replication of pit-free Wolter type-I mirrors for telescopes using quartz glass mandrels. We demonstrated the fabrication process on a Wolter type-I mirror proposed for FOXSI-4 [(FOXSI) Focusing Optics X-ray Solar Imager], resulting in three mirrors obtained from the same mandrel without repolishing or repairing. The figure error of the mirror was within 1 µm over most areas in both longitudinal and circumferential directions. The ray-tracing simulation indicated that the performance of the mirror was ∼12 arcsec in half-power diameter, comparable to the performance achieved by previous high-resolution x-ray missions.


  • Open Access

    Observation of Particle Behavior between Tool and Workpiece in Ultra-Precision Local Machining of Glass Surfaces Using Organic Abrasive

    by Yusuke Matsuzawa, Takehiro Kume, Jianli Guo, Kentaro Hiraguri, Hirokazu Hashizume, Hidekazu Mimura

    Organic abrasive machining (OAM) is a local machining method using organic abrasives and elastic rotating tool with a small-diameter, which is applicable to high-spatial-resolution figure correction of high-precision optical surfaces owing to its low machining rate and small spot size. In order to clarify the machining mechanism of OAM, the particle behavior between the tool and a transparent workpiece was observed in-situ using a microscopic observation system with a high-speed camera. First, the elastic contact area between the tool and workpiece surface was calculated based on Hertzian elastic contact theory, and the tool size for the observation experiment was determined. Next, a microscopic optical system was constructed and the velocity distribution of particles was obtained by in-situ observation. The particles moved linearly along the direction of tool rotation and the speed distribution had a narrow peak width at the center of the contact area. The ratio of particle speed to tool surface speed was independent of the tool rotation conditions (500 rpm to 2000 rpm). The particle speed distribution had a similar profile to the depth distribution of the stationary machining spot.

  • Open Access

    Figure correction of a Wolter mirror master mandrel by organic abrasive machining

    by Satoru Egawa, Yusuke Matsuzawa, Kentaro Hiraguri, Hiroto Motoyama, Gota Yamaguchi, Shunya Yokomae, Yoshinori Takei, Takehiro Kume, Shigeki Owada, Kensuke Tono, et al.

    In this study, figure correction of a master mandrel of a Wolter mirror by organic abrasive machining (OAM) was demonstrated. In OAM, a flow of slurry, dispersed with organic particles, locally removes the surface of a workpiece in contact with a rotating machining tool. A computer-controlled machining system was used to perform the selective removal of a fused silica surface at a spatial resolution of 200 µm. A master mandrel of a Wolter mirror for soft x-ray microscopes was fabricated with a figure accuracy of <1 nm root mean square, which is sufficient for diffraction-limited imaging at a wavelength of 10 nm.


  • Fabrication of soft x-ray monolithic Wolter mirror based on surface scanning measurement using touch probe

    by Takehiro Kume, Kentaro Hiraguri, Yoichi Imamura, Yusuke Matsuzawa, Takahiro Saito, Hiroaki Miyashita, Yoko Takeo, Yasunori Senba, Hikaru Kishimoto, Haruhiko Ohashi, et al.

    The monolithic Wolter mirror is an ideal optical device for focusing soft x rays to a submicron-sized spot, with the advantages of high efficiency, large acceptance, achromaticity, and robustness to alignment error. The fabrication process for this type of mirror has not been established because of the difficulty in highly accurate figure measurement of free-form surfaces with small radii of curvature and steep profiles. In this study, we employed tactile scanning measurement for surface characterization to fabricate a high-precision Wolter mirror. First, it was demonstrated that the touch probe measurement did not leave scratches on the raw surface of the mirror substrate. Next, the measurement capability of the surface profiler was assessed, and the data analysis conditions were determined. Finally, the Wolter mirror was fabricated through repeated figure correction based on the tactile measurement, and the figure error of the final surface was evaluated. Wave-optical simulations that used this error as reference suggested that the size of the beam focused by the mirror was equivalent to the theoretical value at 1000 eV. The reflected image with uniform intensity distribution obtained at SPring-8 also revealed the effectiveness of the present fabrication approach based on tactile measurement.


  • Organic abrasive machining system for optical fabrication with 0.1-mm spatial resolution

    by Yusuke Matsuzawa, Kentaro Hiraguri, Hirokazu Hashizume, Hidekazu Mimura

    High-precision optics for short-wavelength regions, such as x rays and extreme ultraviolet light, generally require nanometer-level figure accuracy on their surfaces. Such optics are finished via a numerically controlled figure correction process in which the dwelling time of the machining tool on the workpiece is controlled. Due to the limitation of the machined spot size, it is difficult to remove mid-spatial-frequency (1 to 10 mm−1) errors on an optical surface. To realize a high-spatial-resolution figure correction process for high-precision optics, we have been developing the organic abrasive machining (OAM) technique, which can generate a 100 µm machined spot using a small elastic rotation tool in a slurry that includes acrylic particles. In this study, an OAM apparatus that can measure the machining load was constructed. The effects of the machining and slurry conditions were investigated and high-spatial-resolution machining on a flat glass substrate was demonstrated. The root-mean-square roughness of the surface after OAM processing was below 0.2 nm. Patterns with a minimum line and space size of 100 µm were successfully fabricated.


  • A highly efficient nanofocusing system for soft x rays

    by Yoko Takeo, Hiroto Motoyama, Takenori Shimamura, Takashi Kimura, Takehiro Kume, Yusuke Matsuzawa, Takahiro Saito, Yoichi Imamura, Hiroaki Miyashita, Kentaro Hiraguri, et al.

    The focusing of x rays is essential in various types of x-ray microscopy because the size and flux of the illuminating beam determine the spatial resolution and signal intensity, respectively. A system with grazing incidence mirrors allows highly efficient x ray focusing with beam dimensions on the nanometer scale. Tube-shaped mirrors with a large numerical aperture and high demagnification, including ellipsoidal mirrors and Wolter mirrors, have recently been developed for soft x-ray nanofocusing. However, these mirrors have low efficiency because they cannot focus the central part of the illumination beam. Here, we propose a two-stage focusing system, in which a ring-shaped beam formed by a ring-focusing mirror illuminates a quasi-Wolter mirror. A prototype of the system is experimentally constructed at beamline BL25SU-A of SPring-8. Observation of the wavefront error based on ptychography enables efficient alignment of the two mirrors. Using this alignment procedure, we achieve a spot size of less than 200 nm at 300 eV.


  • Development of high-order harmonic focusing system based on ellipsoidal mirror

    by H. Motoyama, T. Sato, A. Iwasaki, Y. Takei, T. Kume, S. Egawa, K. Hiraguri, H. Hashizume, K. Yamanouchi, H. Mimura

    We have developed a focusing system for extreme ultraviolet light produced by high-order harmonic generation. An ellipsoidal mirror with a precise surface shape was fabricated and installed into the focusing system. A rigid mirror manipulator and a beam profiler were employed to perform precise and stable mirror alignment. As a demonstration of the focusing performance, high-order harmonics in the wavelength range of 13.5–19.5 nm were successfully focused into a 2.4 × 2.3 μm2 spot.