Yannik Wandael
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Yannik Wandael has a total of 10 co-authors. Here are the top co-authors by number of shared publications:
- Angelo Piermattei
UOC Fisica Sanitaria, Fondazione Policlinico Universitario Agostino Gemelli, 00168 Rome, Italy
1 shared publication - Chiara Arilli
Medical Physics Unit,Azienda Ospedaliero-Universitaria Careggi,Florence,Italy, Italy
1 shared publication - Chiara Galeotti
AOU Careggi, Radiotherapy Unit, 50134 Florence, Italy
1 shared publication - Cinzia Talamonti
Dep. of Experimental and Biomedical Clinical Science,University of Florence,Florence,Italy; Istituto Nazionale di Fisica Nucleare, Sezione di Firenze,Florence,Italy, Italy
1 shared publication - Franco Fusi
Department of Experimental and Clinical Biomedical Sciences “Mario Serio”, University of Florence, Florence, Italy
1 shared publication - Isacco Desideri
Radiation Oncology Unit, Azienda Ospedaliero-Universitaria Careggi, 50134 Florence, Italy
1 shared publication
Latest Publications
- Open Access
- 28 October 2020
- Published by MDPI AG in Applied Sciences
- Vol. 10 (21) , 7611
Combined Use of a Transmission Detector and an EPID-Based In Vivo Dose Monitoring System in External Beam Whole Breast Irradiation: A Study with an Anthropomorphic Female Phantom
We evaluate the combined usage of two systems, the Integral Quality Monitor (IQM) transmission detector and SoftDiso software, for in vivo dose monitoring by simultaneous detection of delivery and patient setup errors in whole breast irradiation. An Alderson RANDO phantom was adapted with silicon breast prostheses to mimic the female anatomy. Plans with simulated delivery errors were created from a reference left breast plan, and patient setup errors were simulated by moving the phantom. Deviations from reference values recorded by both monitoring systems were measured for all plans and phantom positions. A 2D global gamma analysis was performed in SoftDiso for all phantom displacements. Both IQM signals and SoftDiso R-values are sensitive to small MU variations. However, only IQM is sensitive to jaw position variations. Conversely, IQM is unable to detect patient positioning errors, and the R-value has good sensitivity to phantom displacements. A gamma comparison analysis allows one to determine alert thresholds to detect phantom shifts or relatively large rotations. The combined use of the IQM and SoftDiso allows for fast identification of both delivery and setup errors and substantially reduces the impact of error identification and correction on the treatment workflow.
- 28 October 2020
- Published by MDPI AG in Applied Sciences
- Vol. 10 (21) , 7611
Open AccessCombined Use of a Transmission Detector and an EPID-Based In Vivo Dose Monitoring System in External Beam Whole Breast Irradiation: A Study with an Anthropomorphic Female Phantom
We evaluate the combined usage of two systems, the Integral Quality Monitor (IQM) transmission detector and SoftDiso software, for in vivo dose monitoring by simultaneous detection of delivery and patient setup errors in whole breast irradiation. An Alderson RANDO phantom was adapted with silicon breast prostheses to mimic the female anatomy. Plans with simulated delivery errors were created from a reference left breast plan, and patient setup errors were simulated by moving the phantom. Deviations from reference values recorded by both monitoring systems were measured for all plans and phantom positions. A 2D global gamma analysis was performed in SoftDiso for all phantom displacements. Both IQM signals and SoftDiso R-values are sensitive to small MU variations. However, only IQM is sensitive to jaw position variations. Conversely, IQM is unable to detect patient positioning errors, and the R-value has good sensitivity to phantom displacements. A gamma comparison analysis allows one to determine alert thresholds to detect phantom shifts or relatively large rotations. The combined use of the IQM and SoftDiso allows for fast identification of both delivery and setup errors and substantially reduces the impact of error identification and correction on the treatment workflow.