Madi Kabore has a total of 19 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    A Multi-Criteria Policy Coherence Index for Water–Energy–Food Nexus Governance and Energy Transition Pathways in Sub-Saharan Africa

    by Abdoulaye Ballo, Anderson Kehbila, Moses Kirimi, Madi Kabore, Cynthia Sitati, Hyacinth Elayo, Fabio Maria Montagnino, Tsitsi Bangira, Brenda Insonne

    Ensuring sustainable management of water, energy, and food (WEF) resources requires governance frameworks capable of addressing cross-sectoral interdependencies and policy fragmentation. This study evaluates the performance and coherence of national water, energy, and agricultural policies in Mali, South Africa, Malawi, and Tanzania, with a focus on their contribution to WEF nexus integration and energy transition pathways. A mixed-methods approach is applied, combining qualitative policy analysis, stakeholder consultations (n = 52), and a composite policy coherence index to assess cross-sectoral policy alignment across three river basins: the Bani River Basin (Mali), the Songwe River Basin (Malawi–Tanzania), and the Inkomati–Usuthu Water Management Area (South Africa). The results indicate that key water policy dimensions such as conservation, pollution control, and stakeholder participation demonstrate high performance (mean = 1.0) and strong coherence (SD = 0.0–0.1) across all countries. However, these values primarily reflect the presence of policy instruments rather than their effective implementation. Stakeholder evidence highlights persistent gaps in enforcement, coordination, and institutional capacity. In the energy sector, core infrastructure and participation policies exhibit high performance (mean = 1.0; SD = 0.0), while critical market instruments—including feed-in tariffs (FITs) and power purchase agreements (PPAs)—show moderate performance (mean = 0.6–0.8) and high variability (SD = 0.4–0.5), indicating regulatory inconsistency. In the agricultural sector, economic incentives achieve high performance (mean = 1.0; SD = 0.0), whereas sustainable practices such as agroecology, crop rotation, and organic fertilization remain weakly integrated (mean = 0.1–0.4; SD up to 0.5). Overall, the findings reveal that WEF nexus governance is characterized by strong structural policy alignment (mean = 0.8–1.0) but limited functional integration, reflecting a gap between policy design coherence and implementation effectiveness. Strengthening regulatory frameworks, improving cross-sectoral coordination, and enhancing investment mechanisms are critical for advancing resource efficiency and accelerating energy transition. The study provides a reproducible framework for assessing policy coherence and offers policy-relevant insights for integrated resource governance in Sub-Saharan Africa.

  • Enjeux de la simulation pour l'étude des performances énergétiques des bâtiments en Afrique sub-saharienne

    by Madi Kaboré

    Dans les pays de l’Afrique sub-saharienne, la situation énergétique, le fort taux d’accroissement des aires urbaines, l’inadaptation des techniques de construction et le climat offrent un grand potentiel pour la démarche bioclimatique et la construction durable notamment sur le plan énergétique. Cependant ce potentiel est faiblement exploré. Pour ce faire, cela passe par une bonne connaissance du comportement des bâtiments et par leur adaptation au contexte climatique. Dans le cadre de notre contribution à cette problématique, une étude sur le comportement thermique des bâtiments est initiée grâce à la simulation. En effet la simulation des performances énergétiques du bâtiment devient de plus en plus incontournable dans les processus de conception et d’analyse des bâtiments à travers le monde. Dans ce travail les outils de simulation des performances énergétiques ainsi que les outils d’optimisation sont utilisés pour mener des investigations sur un bâtiment type construit en matériaux conventionnels au Burkina Faso suivant deux principales approches. Dans la première approche le modèle numérique du bâtiment est confronté aux mesures issues de l’expérimentation sur le bâtiment réel. Une méthodologie de calibration basée sur l’analyse de sensibilité et l’optimisation des paramètres a été appliquée pour la comparaison des résultats. Cela a permis de caler le modèle et des études diagnostiques sont réalisées. Dans la seconde approche, des investigations sur des solutions d’amélioration des performances du bâtiment sont réalisées à travers l’application de la simulation dynamique comme outils d’aide à la conception. Les techniques d’interopérabilité et d’optimisation sont utilisées pour implémenter les solutions de refroidissement passif dont les impacts sur le bâtiment étudié sont évalués. Enfin dans ce travail, des techniques d’analyse du bâtiment et des critères de performance sont utilisées pour caractériser et formuler des recommandations sur la conception des bâtiments dans notre contexte climatique.

  • Cooling Energy Savings for A Campus Building Using Sustainable Envelope-Case Study.

    by Reda Y. M. Allam, Rafik Belarbi, Madi Kabore, Sherif Sheta

    Electricity consumption of the Egyptian building sectors has an increasing rate from 2014 until now according to annual report for electricity ministry [1]. Hence, this research examines the common building envelope systems after increasing the thermal resistance of exterior envelopes to achieve high energy efficient buildings. That will be attained by: 1- field results for the case under study is used to validate numerical model. Then, the thermal performance for the case study is increased by exterior thermal insulation panels, reduced air infiltration through double glass windows instead of infiltrated single glass windows. 2-Three-dimensional numerical results - TRNSYS v17 program, which demonstrated that, only 0.35 m thick straw panels for the external walls, double glass windows with 1.5 m horizontal shading and 0.6 ach ventilation rate save 26.6 % cooling energy for the building under study. While 0.15 m and 0.2 m expanded polystyrene panels can save 24 % and 23 % respectively.


  • Open Access

    Building and Urban Cooling Performance Indexes of Wetted and Green Roofs—A Case Study under Current and Future Climates

    by Madi Kaboré, Emmanuel Bozonnet, Patrick Salagnac

    We developed and studied key performance indexes and representations of energy simulation heat fluxes to evaluate the performance of the evaporative cooling process as a passive cooling technique for a commercial building typology. These performance indexes, related to indoor thermal comfort, energy consumption and their interactions with their surrounding environments, contribute to understanding the interactions between the urban climate and building for passive cooling integration. We compare the performance indexes for current and future climates (2080), according to the highest emission scenario A2 of the Special Report on Emission Scenario (SRES). Specific building models were adapted with both green roof and wetted roof techniques. The results show that summer thermal discomfort will increase due to climate change and could become as problematic as winter thermal discomfort in a temperate climate. Thanks to evapotranspiration phenomena, the sensible heat contribution of the building to the urban heat island (UHI) is reduced for both current and future climates with a green roof. The performance of the vegetative roof is related to the water content of the substrate. For wetted roofs, the impacts on heat transferred to the surrounding environment are higher for a Mediterranean climate (Marseille), which is warmer and drier than the Paris climate studied (current and future climates). The impact on indoor thermal comfort depends on building insulation, as demonstrated by parametric studies, with higher effects for wetted roofs.


  • Open Access

    Assessment on Passive Cooling Techniques to Improve Steel Roof Thermal Performance in Hot Tropical Climate

    by Madi Kabore, Etienne Wurtz, Yézouma Coulibaly, Adamah Messan, Patrice Moreaux

    In African hot tropical climate countries, due to climate and the unsuitability of construction materials, building’s indoor environment remains over the thermal comfort acceptable limit over long periods of time during the year. Among the building envelope components, roof is a critical part that is highly susceptible to solar radiation. Solutions like passive cooling and low energy consumption systems are not explored enough in those countries. These techniques and systems can be used to meet a large part of the cooling needs and reduce the overheating period in buildings, but their applicability depends on the climate zone. In this paper, investigations were conducted to determine their potential to improve steel roof performance for free running buildings under tropical climatic conditions. The case studies are two configurations (with and without attic) of typical steel roof in Burkina Faso. Using dynamic simulation, we have evaluated the impacts of radiant barrier, insulation, cool paint and ventilation for two configuration of roofing. For both configurations, high reflective solutions perform very well. It also appears that the attic case due to its actual configuration (shape and design) and to the climate conditions ventilation does not perform very well. These results can help building actors during the design process.