Esther Gonzalo
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Esther Gonzalo has a total of 15 co-authors. Here are the top co-authors by number of shared publications:
- Maria Jesus Suarez
Department of Conservative Dentistry and Prosthodontics, Faculty of Dentistry Complutense University of Madrid Madrid Spain
2 shared publications Pedro Diaz
Department of Conservative Dentistry and Bucofacial Prostheses, Faculty of Odontology, Complutense University of Madrid, Madrid, Spain
2 shared publications- Pedro Diaz
Department of Conservative Dentistry and Prosthodontics, Faculty of Dentistry Complutense University of Madrid Madrid Spain
2 shared publications Barbara Miegimolle
University Complutense of Madrid (UCM)
1 shared publication- Barbara Miegimolle
Department of Conservative Dentistry and Bucofacial Prosthesis, Faculty of Odontology, University Complutense of Madrid (UCM), Madrid, Spain
1 shared publication Beatriz Vizoso
Department of Conservative Dentistry and Bucofacial Prostheses, Faculty of Odontology, Complutense University of Madrid, Madrid, Spain
1 shared publication
Latest Publications
- 22 January 2025
- Published by Springer Nature in Clinical Oral Investigations
- Vol. 29 (1) , 1-13
Evaluation of the influence of connection configuration on the implant-abutment interface vertical misfit of original milled titanium and laser-sintered cobalt-chromium abutments
Objectives This study aimed to assess the vertical misfit at the implant-abutment interface in external and internal connections across various implant brands, comparing original milled titanium abutments with laser-sintered cobalt-chromium (Co-Cr) abutments. Materials and methods A total of 160 implants from four different brands were utilized, with 80 featuring external connections (EC) and 80 internal connections (IC). Original milled titanium abutments (n = 160) and Co-Cr laser-sintered abutments (n = 160) were randomly attached to each connection type, following the manufacturer’s recommended torque. After undergoing thermal cycling, the vertical misfit was measured using a scanning electron microscope. Statistical analyses were performed using the Kruskal-Wallis and Mann-Whitney U tests. The significance level was set at α = 0.05. Results The original milled titanium abutments exhibited the lowest misfit values. Significant differences were identified between both abutment types for EC (d = 109.578 μm; p = 0.0001) and IC (d = 44.317 μm; p = 0.002). The EC with laser-sintered abutments demonstrated the highest marginal misfit values, with an average of nearly 30 μm, while a misfit value of 11.382 μm was achieved in the IC. Differences were observed among the brands for milled abutments in both EC and IC. Similarly, variations were also noted for the laser-sintered Co-Cr abutments in EC and IC configurations. Conclusions The vertical misfit of the original milled titanium abutments in all groups was within the clinically acceptable range for IC. The connection type significantly impacted the vertical misfit in laser-sintered Co-Cr abutments. Differences among the implant systems were observed for both connection types and abutment types evaluated. Clinical relevance Using original milled titanium abutments, particularly in internal connection systems, can lead to better fit and stability at the implant-abutment interface, potentially reducing the risk of mechanical complications and improving long-term implant success.
- 22 January 2025
- Published by Springer Nature in Clinical Oral Investigations
- Vol. 29 (1) , 1-13
Evaluation of the influence of connection configuration on the implant-abutment interface vertical misfit of original milled titanium and laser-sintered cobalt-chromium abutments
Objectives This study aimed to assess the vertical misfit at the implant-abutment interface in external and internal connections across various implant brands, comparing original milled titanium abutments with laser-sintered cobalt-chromium (Co-Cr) abutments. Materials and methods A total of 160 implants from four different brands were utilized, with 80 featuring external connections (EC) and 80 internal connections (IC). Original milled titanium abutments (n = 160) and Co-Cr laser-sintered abutments (n = 160) were randomly attached to each connection type, following the manufacturer’s recommended torque. After undergoing thermal cycling, the vertical misfit was measured using a scanning electron microscope. Statistical analyses were performed using the Kruskal-Wallis and Mann-Whitney U tests. The significance level was set at α = 0.05. Results The original milled titanium abutments exhibited the lowest misfit values. Significant differences were identified between both abutment types for EC (d = 109.578 μm; p = 0.0001) and IC (d = 44.317 μm; p = 0.002). The EC with laser-sintered abutments demonstrated the highest marginal misfit values, with an average of nearly 30 μm, while a misfit value of 11.382 μm was achieved in the IC. Differences were observed among the brands for milled abutments in both EC and IC. Similarly, variations were also noted for the laser-sintered Co-Cr abutments in EC and IC configurations. Conclusions The vertical misfit of the original milled titanium abutments in all groups was within the clinically acceptable range for IC. The connection type significantly impacted the vertical misfit in laser-sintered Co-Cr abutments. Differences among the implant systems were observed for both connection types and abutment types evaluated. Clinical relevance Using original milled titanium abutments, particularly in internal connection systems, can lead to better fit and stability at the implant-abutment interface, potentially reducing the risk of mechanical complications and improving long-term implant success.
- Top Cited PapersOpen Access
- 19 October 2022
- Published by Springer Nature in BMC Oral Health
- Vol. 22 (1) , 1-13
What is the prevalence of peri-implantitis? A systematic review and meta-analysis
Background: Peri-implantitis is a usual finding but estimates of its prevalence fluctuate very much. This may be due to the wide variety of disease definitions. This systematic review aims to estimate the overall prevalence of peri-implantitis and the effect of different study designs, function times and use of probing depth on prevalence rate.Methods: Following electronic and manual searches of the literature published from January 2005 to December 2021, data were extracted from the studies fitting the study criteria. Fifty-seven articles were included in this study.Results: Prevalence of peri-implantitis was 19.53% (95% CI 12.87–26.19) at the patient-level, and 12.53% (95% CI 11.67–13.39) at the implant-level and it remains highly variable even following restriction to the clinical case definition. The use of probing depth like diagnostic criteria affected the prevalence data.Conclusion: The results indicate that it remains essential the identification of the diagnostic markers for more accurate disease classification.
- 19 October 2022
- Published by Springer Nature in BMC Oral Health
- Vol. 22 (1) , 1-13
Top Cited PapersOpen AccessWhat is the prevalence of peri-implantitis? A systematic review and meta-analysis
Background: Peri-implantitis is a usual finding but estimates of its prevalence fluctuate very much. This may be due to the wide variety of disease definitions. This systematic review aims to estimate the overall prevalence of peri-implantitis and the effect of different study designs, function times and use of probing depth on prevalence rate.Methods: Following electronic and manual searches of the literature published from January 2005 to December 2021, data were extracted from the studies fitting the study criteria. Fifty-seven articles were included in this study.Results: Prevalence of peri-implantitis was 19.53% (95% CI 12.87–26.19) at the patient-level, and 12.53% (95% CI 11.67–13.39) at the implant-level and it remains highly variable even following restriction to the clinical case definition. The use of probing depth like diagnostic criteria affected the prevalence data.Conclusion: The results indicate that it remains essential the identification of the diagnostic markers for more accurate disease classification.
- Open Access
- 29 November 2021
- Published by Springer Nature in Research Square
What is the Prevalence of Peri-Implantitis? A Systematic Review and Meta-Analysis
Background: Peri-implantitis is a usual finding but estimates of its prevalence fluctuate very much. This may be due to the wide variety of disease definitions. This systematic review aims to estimate the overall prevalence of peri-implantitis and the effect of different study designs, function times, and use of probing depth on prevalence rate.Methods: Following electronic and manual searches of the literature published from January 2005 to December 2020, data were extracted from the studies fitting the study criteria. Fifty-seven articles were included in this study.Results: Prevalence of peri-implantitis was 19.6% (95% CI, 15.25-24.75) at the patient-level, and 12.39% (95% CI, 9.46-15.43) at the implant-level and it remains highly variable even following restriction to the clinical case definition. The use of probing depth like diagnostic criteria affected the prevalence data.Conclusion: The results indicate that it remains essential the identification of the diagnostic markers for more accurate disease classification.
- 29 November 2021
- Published by Springer Nature in Research Square
Open AccessWhat is the Prevalence of Peri-Implantitis? A Systematic Review and Meta-Analysis
Background: Peri-implantitis is a usual finding but estimates of its prevalence fluctuate very much. This may be due to the wide variety of disease definitions. This systematic review aims to estimate the overall prevalence of peri-implantitis and the effect of different study designs, function times, and use of probing depth on prevalence rate.Methods: Following electronic and manual searches of the literature published from January 2005 to December 2020, data were extracted from the studies fitting the study criteria. Fifty-seven articles were included in this study.Results: Prevalence of peri-implantitis was 19.6% (95% CI, 15.25-24.75) at the patient-level, and 12.39% (95% CI, 9.46-15.43) at the implant-level and it remains highly variable even following restriction to the clinical case definition. The use of probing depth like diagnostic criteria affected the prevalence data.Conclusion: The results indicate that it remains essential the identification of the diagnostic markers for more accurate disease classification.
- Open Access
Evaluation of Milled Titanium versus Laser Sintered Co-Cr Abutments on the Marginal Misfit in Internal Implant-Abutment Connection
The precision of fit at the implant-abutment connection is an important criterion for the clinical success of restorations and implants. Several factors are involved among which are the abutment materials and manufacturing techniques. The aim of this study was to investigate the effect of two materials and methods of manufacturing implant abutments, milled titanium versus laser sintered Co-Cr, on the marginal misfit at the implant-abutment interface. Scanning electron microscopes (SEM) were used to geometrically measure the marginal vertical discrepancy of a total of 80 specimens, classified into eight categories, according to the implant system and abutment. The data were statistically analyzed by Student’s paired t test, one-way and two-way ANOVA with the Bonferroni-Holm correction at the significance level of p = 0.05. Milled titanium abutments demonstrated the lowest misfit values in the implant systems analyzed. The marginal fit of all the groups was within the clinically acceptable range for implant prostheses.
Open AccessEvaluation of Milled Titanium versus Laser Sintered Co-Cr Abutments on the Marginal Misfit in Internal Implant-Abutment Connection
The precision of fit at the implant-abutment connection is an important criterion for the clinical success of restorations and implants. Several factors are involved among which are the abutment materials and manufacturing techniques. The aim of this study was to investigate the effect of two materials and methods of manufacturing implant abutments, milled titanium versus laser sintered Co-Cr, on the marginal misfit at the implant-abutment interface. Scanning electron microscopes (SEM) were used to geometrically measure the marginal vertical discrepancy of a total of 80 specimens, classified into eight categories, according to the implant system and abutment. The data were statistically analyzed by Student’s paired t test, one-way and two-way ANOVA with the Bonferroni-Holm correction at the significance level of p = 0.05. Milled titanium abutments demonstrated the lowest misfit values in the implant systems analyzed. The marginal fit of all the groups was within the clinically acceptable range for implant prostheses.