Eloisa Comiran
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Eloisa Comiran has a total of 57 co-authors. Here are the top co-authors by number of shared publications:
Renata Pereira Limberger
Postgraduate Program in Pharmaceutical Sciences, Federal University of Rio Grande do Sul, Av. Ipiranga, 2752, 90610-000 Porto Alegre, RS, Brazil
6 shared publicationsFlavio Pechansky
Center for Drug and Alcohol Research, Collaborating Center on Alcohol and Drugs - HCPA/SENAD, Hospital de Clínicas de Porto Alegre, Federal University of Rio Grande do Sul, Rua Professor Álvaro Alvim, 400, 90420-020 Porto Alegre, RS, Brazil
5 shared publicationsPedro Eduardo Fröehlich
Postgraduate Program in Pharmaceutical Sciences, Federal University of Rio Grande do Sul, Av. Ipiranga, 2752, 90610-000 Porto Alegre, RS, Brazil
4 shared publicationsGraciela Carlos
Graduate Studies Program in Pharmaceutical Sciences Faculty of Pharmacy Federal University of Rio Grande do Sul Porto Alegre Rio Grande do Sul Brazil
3 shared publications- Raquel Brandini De Boni
Institute of Scientific and Technological Communication and Information in Health (ICICT), Oswaldo Cruz Foundation (Fiocruz), Rio de Janeiro, Brazil
3 shared publications Bruna Claudia Coppe
Graduate Program in Pharmaceutical Sciences, College of Pharmacy, Federal University of Rio Grande do Sul, Porto Alegre, Brazil
2 shared publications
Latest Publications
- 29 October 2020
- Published by Wiley in Biopharmaceutics & Drug Disposition
- Vol. 42 (1) , 3-11
Lisdexamfetamine and amphetamine pharmacokinetics in oral fluid, plasma, and urine after controlled oral administration of lisdexamfetamine
Lisdexamfetamine (LDX) is a long‐acting prodrug stimulant indicated for the treatment of attention‐deficit/hyperactivity disorder (ADHD) and binge‐eating disorder (BED) symptoms. In vivo hydrolysis of the LDX amide bond releases the therapeutically active d‐amphetamine (d‐AMPH). This study aims to describe the pharmacokinetics of LDX and its major metabolite d‐AMPH in human oral fluid, urine and plasma after a single 70 mg oral dose of LDX dimesylate. Six volunteers participated in the study. Oral fluid and blood samples were collected for up to 72 h and urine for up to 120 h post‐drug administration for the pharmacokinetic evaluation of intact LDX and d‐AMPH. Samples were analyzed by LC‐MS/MS. Regarding noncompartmental analysis, d‐AMPH reached the maximum concentration at 3.8 and 4 h post‐administration in plasma and oral fluid, respectively, with a mean peak concentration value almost six‐fold higher in oral fluid. LDX reached maximum concentration at 1.2 and 1.8 h post‐administration in plasma and oral fluid, respectively, with a mean peak concentration value almost three‐fold higher in plasma. Intact LDX and d‐AMPH were detected in the three matrices. The best fit of compartmental analysis was found in the one‐compartment model for both analytes in plasma and oral fluid. There was a correlation between oral fluid and plasma d‐AMPH concentrations and between parent to metabolite concentration ratios over time in plasma as well as in oral fluid.
- 29 October 2020
- Published by Wiley in Biopharmaceutics & Drug Disposition
- Vol. 42 (1) , 3-11
Lisdexamfetamine and amphetamine pharmacokinetics in oral fluid, plasma, and urine after controlled oral administration of lisdexamfetamine
Lisdexamfetamine (LDX) is a long‐acting prodrug stimulant indicated for the treatment of attention‐deficit/hyperactivity disorder (ADHD) and binge‐eating disorder (BED) symptoms. In vivo hydrolysis of the LDX amide bond releases the therapeutically active d‐amphetamine (d‐AMPH). This study aims to describe the pharmacokinetics of LDX and its major metabolite d‐AMPH in human oral fluid, urine and plasma after a single 70 mg oral dose of LDX dimesylate. Six volunteers participated in the study. Oral fluid and blood samples were collected for up to 72 h and urine for up to 120 h post‐drug administration for the pharmacokinetic evaluation of intact LDX and d‐AMPH. Samples were analyzed by LC‐MS/MS. Regarding noncompartmental analysis, d‐AMPH reached the maximum concentration at 3.8 and 4 h post‐administration in plasma and oral fluid, respectively, with a mean peak concentration value almost six‐fold higher in oral fluid. LDX reached maximum concentration at 1.2 and 1.8 h post‐administration in plasma and oral fluid, respectively, with a mean peak concentration value almost three‐fold higher in plasma. Intact LDX and d‐AMPH were detected in the three matrices. The best fit of compartmental analysis was found in the one‐compartment model for both analytes in plasma and oral fluid. There was a correlation between oral fluid and plasma d‐AMPH concentrations and between parent to metabolite concentration ratios over time in plasma as well as in oral fluid.
- 1 November 2018
- Published by Taylor & Francis in Drug Development and Industrial Pharmacy
- Vol. 45 (1) , 139-146
Assessment of lisdexamfetamine dimesylate stability and identification of its degradation product by NMR spectroscopy
Lisdexamfetamine dimesylate (LDX), a long-acting prodrug stimulant indicated for the treatment of the attention-deficit/hyperactivity disorder (ADHD), was subjected to forced degradation studies by acid and alkaline hydrolysis and the degradation profile was studied. To obtain between 10–30% of degraded product, acid and alkaline conditions were assessed with solutions of 0.01 M, 0.1 M, 0.5 M, and 1 M of DCl and NaOD. These solutions were analyzed through 1 H NMR spectra. Acid hydrolysis produced no degradation in 0.01 M and 0.1 M DCl and 4.38%, 9.69%, and 17.75% of degradation LDX, respectively, in 0.5 M, 1 M (4h) and 1 M (4 + 12 h) DCl. And alkaline hydrolysis produced no degradation in 0.01 M and 0.1 M DCl and a degradation LDX extension of 8.5%, 14.30%, and 22.91%, respectively, in 0.5 M, 1 M (4h) and 1 M (4 + 12 h) NaOD. LDX solutions subjected to 1 M (4 + 12 h) acid and alkaline hydrolysis were evaluated by NMR spectra (1 H NMR, 13 C NMR, HSQC and HMBC). LDX degradation product (DP) was identified and its structure elucidated as a diastereoisomer of LDX: (2R)-2,6-diamino-N-[(2S)-1-phenylpropan-2-yl] hexanamide without their physical separation.
- 1 November 2018
- Published by Taylor & Francis in Drug Development and Industrial Pharmacy
- Vol. 45 (1) , 139-146
Assessment of lisdexamfetamine dimesylate stability and identification of its degradation product by NMR spectroscopy
Lisdexamfetamine dimesylate (LDX), a long-acting prodrug stimulant indicated for the treatment of the attention-deficit/hyperactivity disorder (ADHD), was subjected to forced degradation studies by acid and alkaline hydrolysis and the degradation profile was studied. To obtain between 10–30% of degraded product, acid and alkaline conditions were assessed with solutions of 0.01 M, 0.1 M, 0.5 M, and 1 M of DCl and NaOD. These solutions were analyzed through 1 H NMR spectra. Acid hydrolysis produced no degradation in 0.01 M and 0.1 M DCl and 4.38%, 9.69%, and 17.75% of degradation LDX, respectively, in 0.5 M, 1 M (4h) and 1 M (4 + 12 h) DCl. And alkaline hydrolysis produced no degradation in 0.01 M and 0.1 M DCl and a degradation LDX extension of 8.5%, 14.30%, and 22.91%, respectively, in 0.5 M, 1 M (4h) and 1 M (4 + 12 h) NaOD. LDX solutions subjected to 1 M (4 + 12 h) acid and alkaline hydrolysis were evaluated by NMR spectra (1 H NMR, 13 C NMR, HSQC and HMBC). LDX degradation product (DP) was identified and its structure elucidated as a diastereoisomer of LDX: (2R)-2,6-diamino-N-[(2S)-1-phenylpropan-2-yl] hexanamide without their physical separation.
- Open Access
- 24 July 2018
- Published by Revista de Saude Publica do Parana in Revista de Saúde Pública do Paraná
- Vol. 1 (1) , 91-100
O serviço de entrega de medicamentos em casa como forma de melhoria do acesso em saúde pública
A Farmácia do Paraná, 2ª Regional de Saúde Metropolitana, implementou o serviço de entrega em casa de medicamentos do Componente Especializado da Assistência Farmacêutica na forma de um projeto piloto no ano de 2017. Este serviço atende aos usuários idosos portadores de doenças crônicas que utilizam medicamentos de uso contínuo previamente elencados para este serviço. A entrega em casa tem como objetivo facilitar o acesso dos usuários idosos ao seu tratamento tendo em vista a dificuldade de muitos em se deslocarem até a farmácia. Além disso, impacta no melhoramento do fluxo de atendimento a todos os usuários, diminuindo o tempo de espera.
- 24 July 2018
- Published by Revista de Saude Publica do Parana in Revista de Saúde Pública do Paraná
- Vol. 1 (1) , 91-100
Open AccessO serviço de entrega de medicamentos em casa como forma de melhoria do acesso em saúde pública
A Farmácia do Paraná, 2ª Regional de Saúde Metropolitana, implementou o serviço de entrega em casa de medicamentos do Componente Especializado da Assistência Farmacêutica na forma de um projeto piloto no ano de 2017. Este serviço atende aos usuários idosos portadores de doenças crônicas que utilizam medicamentos de uso contínuo previamente elencados para este serviço. A entrega em casa tem como objetivo facilitar o acesso dos usuários idosos ao seu tratamento tendo em vista a dificuldade de muitos em se deslocarem até a farmácia. Além disso, impacta no melhoramento do fluxo de atendimento a todos os usuários, diminuindo o tempo de espera.
- 8 May 2018
- Published by Royal Society of Chemistry (RSC) in Analytical Methods
- Vol. 10 (19) , 2287-2292
Photodegradation kinetics of lisdexamfetamine dimesylate and structure elucidation of its degradation products by LC-ESI-QTOF
Herein, we investigate the photodegradation of lisdexamfetamine (LDX) in an aqueous solution. The experiment is carried out by exposing the drug in solution to UV radiation for different periods of time during 48 h. The fragmentation pattern of LDX is established, and its two degradation products are identified (DP-01 and DP-02) and structurally characterized via liquid chromatography coupled with hybrid quadrupole time-of-flight electrospray ionization (LC-ESI-QTOF) mass spectrometry. Furthermore, the photodegradation kinetics of LDX is determined via LC-ESI-QTOF (r = 0.9905; k = 0.0204 h−1; and t1/2 = 33.91 h) and RP-LC-CAD (r = 0.9960; k = 0.0234 h−1; and t1/2 = 29.67 h). LDX is found to be unstable in the presence of light under the evaluated conditions.
- 8 May 2018
- Published by Royal Society of Chemistry (RSC) in Analytical Methods
- Vol. 10 (19) , 2287-2292
Photodegradation kinetics of lisdexamfetamine dimesylate and structure elucidation of its degradation products by LC-ESI-QTOF
Herein, we investigate the photodegradation of lisdexamfetamine (LDX) in an aqueous solution. The experiment is carried out by exposing the drug in solution to UV radiation for different periods of time during 48 h. The fragmentation pattern of LDX is established, and its two degradation products are identified (DP-01 and DP-02) and structurally characterized via liquid chromatography coupled with hybrid quadrupole time-of-flight electrospray ionization (LC-ESI-QTOF) mass spectrometry. Furthermore, the photodegradation kinetics of LDX is determined via LC-ESI-QTOF (r = 0.9905; k = 0.0204 h−1; and t1/2 = 33.91 h) and RP-LC-CAD (r = 0.9960; k = 0.0234 h−1; and t1/2 = 29.67 h). LDX is found to be unstable in the presence of light under the evaluated conditions.
- Open Access
- 1 November 2016
- Published by Scientific Scholar in Arabian Journal of Chemistry
- Vol. 9, S1905-S1914
Development, validation and comparison of two stability-indicating RP-LC methods using charged aerosol and UV detectors for analysis of lisdexamfetamine dimesylate in capsules
Two new stability-indicating liquid chromatographic methods using two detectors, an ultraviolet (UV) and a charged aerosol detector (CAD) simultaneously connected in series were validated for the assessment of lisdexamfetamine dimesylate (LDX) in capsule. The method was optimized and the influence of individual parameters on UV and CAD response and sensitivity was studied. Chromatography was performed on a Zorbax CN column (250mm×4.6mm, 5μm) in an isocratic elution mode, using acetonitrile and 20mM ammonium formate at pH 4.0 (50:50, v/v) as mobile phase and UV detection at 207nm. The developed method was validated according to ICH guidelines and the parameters’ specificity, limit of detection, limit of quantitation, linearity, accuracy, precision and robustness were evaluated. CAD is designated to be a non-linear detector in a wide dynamic range, however, the method was linear over the concentration range of 70–130μgmL−1 in both detectors. The method was precise and accurate. Robustness study was performed by a Plackett–Burman design, delivering results within the acceptable range. Neither the excipients nor the degradation products showed interference in the method after studies of specificity as well as under stress conditions. The results of the LC-UV and LC-CAD methods were statistically compared through ANOVA and showed no significant difference (p>0.05). Both proposed methods could be considered interchangeable and stability-indicating, and can be applied as an appropriate quality control tool for routine analysis of LDX in capsule
- 1 November 2016
- Published by Scientific Scholar in Arabian Journal of Chemistry
- Vol. 9, S1905-S1914
Open AccessDevelopment, validation and comparison of two stability-indicating RP-LC methods using charged aerosol and UV detectors for analysis of lisdexamfetamine dimesylate in capsules
Two new stability-indicating liquid chromatographic methods using two detectors, an ultraviolet (UV) and a charged aerosol detector (CAD) simultaneously connected in series were validated for the assessment of lisdexamfetamine dimesylate (LDX) in capsule. The method was optimized and the influence of individual parameters on UV and CAD response and sensitivity was studied. Chromatography was performed on a Zorbax CN column (250mm×4.6mm, 5μm) in an isocratic elution mode, using acetonitrile and 20mM ammonium formate at pH 4.0 (50:50, v/v) as mobile phase and UV detection at 207nm. The developed method was validated according to ICH guidelines and the parameters’ specificity, limit of detection, limit of quantitation, linearity, accuracy, precision and robustness were evaluated. CAD is designated to be a non-linear detector in a wide dynamic range, however, the method was linear over the concentration range of 70–130μgmL−1 in both detectors. The method was precise and accurate. Robustness study was performed by a Plackett–Burman design, delivering results within the acceptable range. Neither the excipients nor the degradation products showed interference in the method after studies of specificity as well as under stress conditions. The results of the LC-UV and LC-CAD methods were statistically compared through ANOVA and showed no significant difference (p>0.05). Both proposed methods could be considered interchangeable and stability-indicating, and can be applied as an appropriate quality control tool for routine analysis of LDX in capsule
- 15 September 2016
- Published by Wiley in Biomedical Chromatography
- Vol. 31 (3)
Method validation and determination of lisdexamfetamine and amphetamine in oral fluid, plasma and urine by LC–MS/MS
Lisdexamfetamine (LDX) is a long‐acting prodrug stimulant indicated for the treatment of attention‐deficit/hyperactivity disorder and binge‐eating disorder symptoms. In vivo hydrolysis of LDX amide bond releases the therapeutically active d‐amphetamine (d‐AMPH). Since toxicological tests in biological samples can detect AMPH from the use of some legal medications, efficient methods are needed in order to correctly interpret the results. The aim of this study was to develop and validate an LC–MS/MS method for the simultaneous quantification of LDX and its main biotransformation product AMPH in human oral fluid, plasma and urine. Calibration curve range for both analytes was 1–128 ng/mL in oral fluid and plasma and 4–256 ng/mL in urine, being the lowest concentration the limit of quantification. Accuracy of the determined values of the target analytes for the five control levels ranged from 94.8 to 111.7% for oral fluid, from 91.3 to 100.2% for plasma and from 94.8 to 109.8% for urine. Imprecision for the five control levels did not exceeded 12.8% for oral fluid, 16.2% for plasma and 17.1% for urine. The method developed for the three matrices was validated and was also successfully applied to assess real samples, showing for the first time the detection of LDX in oral fluid.
- 15 September 2016
- Published by Wiley in Biomedical Chromatography
- Vol. 31 (3)
Method validation and determination of lisdexamfetamine and amphetamine in oral fluid, plasma and urine by LC–MS/MS
Lisdexamfetamine (LDX) is a long‐acting prodrug stimulant indicated for the treatment of attention‐deficit/hyperactivity disorder and binge‐eating disorder symptoms. In vivo hydrolysis of LDX amide bond releases the therapeutically active d‐amphetamine (d‐AMPH). Since toxicological tests in biological samples can detect AMPH from the use of some legal medications, efficient methods are needed in order to correctly interpret the results. The aim of this study was to develop and validate an LC–MS/MS method for the simultaneous quantification of LDX and its main biotransformation product AMPH in human oral fluid, plasma and urine. Calibration curve range for both analytes was 1–128 ng/mL in oral fluid and plasma and 4–256 ng/mL in urine, being the lowest concentration the limit of quantification. Accuracy of the determined values of the target analytes for the five control levels ranged from 94.8 to 111.7% for oral fluid, from 91.3 to 100.2% for plasma and from 94.8 to 109.8% for urine. Imprecision for the five control levels did not exceeded 12.8% for oral fluid, 16.2% for plasma and 17.1% for urine. The method developed for the three matrices was validated and was also successfully applied to assess real samples, showing for the first time the detection of LDX in oral fluid.
- 1 June 2016
- Published by Elsevier in European Journal of Pharmaceutical Sciences
- Vol. 89, 172-179
Lisdexamfetamine: A pharmacokinetic review
- 1 June 2016
- Published by Elsevier in European Journal of Pharmaceutical Sciences
- Vol. 89, 172-179
Lisdexamfetamine: A pharmacokinetic review
- 24 February 2015
- Published by Royal Society of Chemistry (RSC) in Analytical Methods
- Vol. 7 (7) , 2936-2942
Detection of ethanol in Brazilian gasoline station attendants
In Brazil, gasoline station attendants are regularly exposed to the ethanol contained in fuel, as well as the one used as the gasoline additive. This study aimed to assess the potential exposure of these workers to fuels, using breathalyzers and oral fluid (OF) analysis by headspace gas chromatography/mass spectrometry (HS-GC/MS). Attendants of 26 gasoline stations were invited to respond to a questionnaire covering the main features of the study population and the profile of drinking and driving behavior, followed by a breath test and OF collection with a Quantisal™ device. All OF samples were analyzed by HS-GC/MS. Ethanol was found in 100% of the OF samples whereas 72.83% had concentrations above the quantification limit of the method (0.00125 g dL−1). Regarding the breath tests, only one exhaled air sample (0.62%) showed a positive result (0.03 mg L−1). The positive results in OF samples and negative results in exhaled air may be explained by the higher sensitivity of OF analysis by HS-GC/MS, when compared to the breathalyzer.
- 24 February 2015
- Published by Royal Society of Chemistry (RSC) in Analytical Methods
- Vol. 7 (7) , 2936-2942
Detection of ethanol in Brazilian gasoline station attendants
In Brazil, gasoline station attendants are regularly exposed to the ethanol contained in fuel, as well as the one used as the gasoline additive. This study aimed to assess the potential exposure of these workers to fuels, using breathalyzers and oral fluid (OF) analysis by headspace gas chromatography/mass spectrometry (HS-GC/MS). Attendants of 26 gasoline stations were invited to respond to a questionnaire covering the main features of the study population and the profile of drinking and driving behavior, followed by a breath test and OF collection with a Quantisal™ device. All OF samples were analyzed by HS-GC/MS. Ethanol was found in 100% of the OF samples whereas 72.83% had concentrations above the quantification limit of the method (0.00125 g dL−1). Regarding the breath tests, only one exhaled air sample (0.62%) showed a positive result (0.03 mg L−1). The positive results in OF samples and negative results in exhaled air may be explained by the higher sensitivity of OF analysis by HS-GC/MS, when compared to the breathalyzer.
- 30 April 2014
- Published by Royal Society of Chemistry (RSC) in Analytical Methods
- Vol. 6 (15) , 6095-6104
Extraction optimization using Box–Behnken design and method validation for ethanol in oral fluid
In Brazil, routine verification of alcohol use amongst drivers is performed using breath alcohol analyzers and confirmation of ethanol in blood, using the headspace (HS) technique associated with gas chromatography with a flame ionization detector (GC/FID). Oral fluid (OF) is an alternative that, once collected, can be used both for screening and confirmation, and has many advantages. We propose an optimization of the extraction of ethanol from OF using the HS through experimental design and subsequent development and validation of an analytical method using HS-GC/FID and HS-GC/MS (mass spectrometry), using Quantisal® as a collection device. Experimental design was performed using the Box–Behnken design, and the evaluated parameters were heating temperature, stirring time and injection volume. Selectivity, residual effect, matrix effect, linearity, precision, accuracy, limits of detection and quantification, stability and recovery were evaluated in the validation process. The optimized conditions for extraction were: a temperature of 90 °C, an injection volume of 1000 μL, and a stirring time of 7 min. Linearity was obtained with an R2 greater than 0.99. The accuracy for the quality control samples remained within 101.56 and 111.2 of the target concentrations, whilst the precision did not exceed 12% of their relative standard deviations. The developed method showed full viability of performance, proving to be rapid and sensitive, as it does not require sample preparation steps. The HS-GC/MS method had detection limits lower than those of HS-GC/FID, and can be easily applied for routine confirmation of ethanol in drivers.
- 30 April 2014
- Published by Royal Society of Chemistry (RSC) in Analytical Methods
- Vol. 6 (15) , 6095-6104
Extraction optimization using Box–Behnken design and method validation for ethanol in oral fluid
In Brazil, routine verification of alcohol use amongst drivers is performed using breath alcohol analyzers and confirmation of ethanol in blood, using the headspace (HS) technique associated with gas chromatography with a flame ionization detector (GC/FID). Oral fluid (OF) is an alternative that, once collected, can be used both for screening and confirmation, and has many advantages. We propose an optimization of the extraction of ethanol from OF using the HS through experimental design and subsequent development and validation of an analytical method using HS-GC/FID and HS-GC/MS (mass spectrometry), using Quantisal® as a collection device. Experimental design was performed using the Box–Behnken design, and the evaluated parameters were heating temperature, stirring time and injection volume. Selectivity, residual effect, matrix effect, linearity, precision, accuracy, limits of detection and quantification, stability and recovery were evaluated in the validation process. The optimized conditions for extraction were: a temperature of 90 °C, an injection volume of 1000 μL, and a stirring time of 7 min. Linearity was obtained with an R2 greater than 0.99. The accuracy for the quality control samples remained within 101.56 and 111.2 of the target concentrations, whilst the precision did not exceed 12% of their relative standard deviations. The developed method showed full viability of performance, proving to be rapid and sensitive, as it does not require sample preparation steps. The HS-GC/MS method had detection limits lower than those of HS-GC/FID, and can be easily applied for routine confirmation of ethanol in drivers.