Myoung Hoon Jung
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Myoung Hoon Jung has a total of 13 co-authors. Here are the top co-authors by number of shared publications:
- Kunsun Eom
Digital Health Team, Mobile Experience Samsung Electronics Co. Ltd Suwon Republic of Korea
2 shared publications - Alexander Zhbanov
School of Mechanical Engineering, Gwangju Institute of Science and Technology (GIST), Gwangju, Republic of Korea
1 shared publication - Hyojee Joung
Department of Public Health, Graduate School of Public Health, Seoul National University, Seoul 08826, Republic of Korea
1 shared publication - Hyun Seok Moon
Health H/W R&D Group, Device eXperience (DX), Samsung Electronics Co., Ltd., Suwon 16678, Republic of Korea
1 shared publication - Jeong-Eun Hwang
Device Research Center, Samsung Advanced Institute of Technology (SAIT), Samsung Electronics Co., Ltd., Suwon 16678, Republic of Korea
1 shared publication - Jin-Young Park
Digital Health Team, Mobile Experience Samsung Electronics Co. Ltd Suwon Republic of Korea
1 shared publication
Latest Publications
- Open Access
Evaluation of a Commercial Device Based on Reflection Spectroscopy as an Alternative to Resonance Raman Spectroscopy in Measuring Skin Carotenoid Levels: Randomized Controlled Trial
Resonance Raman spectroscopy (RRS) has been used as a reference method for measuring skin carotenoid levels (SCL), which indicate vegetable and fruit intake. However, RRS is not an easy-to-use method in SCL measurement due to its complicated implementation. In this study, a commercial spectrophotometer based on reflection spectroscopy (RS), which is relatively simple and inexpensive, was evaluated to confirm usability compared with RRS in measuring SCL. To investigate the agreement between RS and RRS, eighty participants were randomly assigned to a high-carotenoid diet group (21 mg/day of total carotenoids) or a control-carotenoid diet group (14 mg/day of total carotenoids) during a 6-week whole-diet intervention period and a 4-week tracking period. Strong correlations between the RS and RRS methods were observed at baseline (r = 0.944) and the entire period (r = 0.930). The rate of SCL increase was similar during the diet intervention; however, the initiation of the SCL decrease in RS was slower than in RRS during the tracking period. To confirm the agreement of RS and RRS from various perspectives, new visualization tools and indices were additionally applied and confirmed the similar response patterns of the two methods. The results indicate that the proposed RS method could be an alternative to RRS in SCL measurements.
Open AccessEvaluation of a Commercial Device Based on Reflection Spectroscopy as an Alternative to Resonance Raman Spectroscopy in Measuring Skin Carotenoid Levels: Randomized Controlled Trial
Resonance Raman spectroscopy (RRS) has been used as a reference method for measuring skin carotenoid levels (SCL), which indicate vegetable and fruit intake. However, RRS is not an easy-to-use method in SCL measurement due to its complicated implementation. In this study, a commercial spectrophotometer based on reflection spectroscopy (RS), which is relatively simple and inexpensive, was evaluated to confirm usability compared with RRS in measuring SCL. To investigate the agreement between RS and RRS, eighty participants were randomly assigned to a high-carotenoid diet group (21 mg/day of total carotenoids) or a control-carotenoid diet group (14 mg/day of total carotenoids) during a 6-week whole-diet intervention period and a 4-week tracking period. Strong correlations between the RS and RRS methods were observed at baseline (r = 0.944) and the entire period (r = 0.930). The rate of SCL increase was similar during the diet intervention; however, the initiation of the SCL decrease in RS was slower than in RRS during the tracking period. To confirm the agreement of RS and RRS from various perspectives, new visualization tools and indices were additionally applied and confirmed the similar response patterns of the two methods. The results indicate that the proposed RS method could be an alternative to RRS in SCL measurements.
- Open Access
Temperature Correction to Enhance Blood Glucose Monitoring Accuracy Using Electrical Impedance Spectroscopy
Electrical methods are among the primarily studied non-invasive glucose measurement techniques; however, various factors affect the accuracy of the sensors used. Of these, the temperature is a critical factor; hence, the effects of temperature on the electrical properties of blood components are investigated in this study. Furthermore, the changes in the electrical properties of blood according to the glucose level are corrected by considering the effects of temperature on the electrical properties. An impedance sensor is developed and used to measure whole blood impedance in 10 healthy participants at various temperatures and glucose levels. Subsequently, the conductivities of the plasma and cytoplasm were extracted. Changes in the electrical properties of the blood components are then analyzed using linear regression and repeated measures ANOVA. The electrical conductivities of plasma and cytoplasm increased with increasing temperatures (plasma: 0.0397 (slope), 0.7814 (R2), cytoplasm: 0.014 (slope), 0.694 (R2)). At three values of increasing glucose levels (85.4, 158.1, and 271.8 mg/dL), the electrical conductivities of the plasma and cytoplasm decreased. These tendencies are more significant upon temperature corrections (p-values; plasma: 0.001, 0.001, cytoplasm: 0.003, 0.002). The relationships between temperature and electrical conductivity changes can thus be used for temperature corrections in blood glucose measurement.
Open AccessTemperature Correction to Enhance Blood Glucose Monitoring Accuracy Using Electrical Impedance Spectroscopy
Electrical methods are among the primarily studied non-invasive glucose measurement techniques; however, various factors affect the accuracy of the sensors used. Of these, the temperature is a critical factor; hence, the effects of temperature on the electrical properties of blood components are investigated in this study. Furthermore, the changes in the electrical properties of blood according to the glucose level are corrected by considering the effects of temperature on the electrical properties. An impedance sensor is developed and used to measure whole blood impedance in 10 healthy participants at various temperatures and glucose levels. Subsequently, the conductivities of the plasma and cytoplasm were extracted. Changes in the electrical properties of the blood components are then analyzed using linear regression and repeated measures ANOVA. The electrical conductivities of plasma and cytoplasm increased with increasing temperatures (plasma: 0.0397 (slope), 0.7814 (R2), cytoplasm: 0.014 (slope), 0.694 (R2)). At three values of increasing glucose levels (85.4, 158.1, and 271.8 mg/dL), the electrical conductivities of the plasma and cytoplasm decreased. These tendencies are more significant upon temperature corrections (p-values; plasma: 0.001, 0.001, cytoplasm: 0.003, 0.002). The relationships between temperature and electrical conductivity changes can thus be used for temperature corrections in blood glucose measurement.