MJMyoung Hoon Jung

Myoung Hoon Jung

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Myoung Hoon Jung has a total of 13 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Evaluation of a Commercial Device Based on Reflection Spectroscopy as an Alternative to Resonance Raman Spectroscopy in Measuring Skin Carotenoid Levels: Randomized Controlled Trial

    by Jeong-Eun Hwang, Jin-Young Park, Myoung Hoon Jung, Kunsun Eom, Hyun Seok Moon, Hyojee Joung, Yoon Jae Kim

    Resonance Raman spectroscopy (RRS) has been used as a reference method for measuring skin carotenoid levels (SCL), which indicate vegetable and fruit intake. However, RRS is not an easy-to-use method in SCL measurement due to its complicated implementation. In this study, a commercial spectrophotometer based on reflection spectroscopy (RS), which is relatively simple and inexpensive, was evaluated to confirm usability compared with RRS in measuring SCL. To investigate the agreement between RS and RRS, eighty participants were randomly assigned to a high-carotenoid diet group (21 mg/day of total carotenoids) or a control-carotenoid diet group (14 mg/day of total carotenoids) during a 6-week whole-diet intervention period and a 4-week tracking period. Strong correlations between the RS and RRS methods were observed at baseline (r = 0.944) and the entire period (r = 0.930). The rate of SCL increase was similar during the diet intervention; however, the initiation of the SCL decrease in RS was slower than in RRS during the tracking period. To confirm the agreement of RS and RRS from various perspectives, new visualization tools and indices were additionally applied and confirmed the similar response patterns of the two methods. The results indicate that the proposed RS method could be an alternative to RRS in SCL measurements.


  • Open Access

    Temperature Correction to Enhance Blood Glucose Monitoring Accuracy Using Electrical Impedance Spectroscopy

    by Ye Sung Lee, Minkook Son, Alexander Zhbanov, Yugyung Jung, Myoung Hoon Jung, Kunsun Eom, Sung Hyun Nam, Jongae Park, Sung Yang

    Electrical methods are among the primarily studied non-invasive glucose measurement techniques; however, various factors affect the accuracy of the sensors used. Of these, the temperature is a critical factor; hence, the effects of temperature on the electrical properties of blood components are investigated in this study. Furthermore, the changes in the electrical properties of blood according to the glucose level are corrected by considering the effects of temperature on the electrical properties. An impedance sensor is developed and used to measure whole blood impedance in 10 healthy participants at various temperatures and glucose levels. Subsequently, the conductivities of the plasma and cytoplasm were extracted. Changes in the electrical properties of the blood components are then analyzed using linear regression and repeated measures ANOVA. The electrical conductivities of plasma and cytoplasm increased with increasing temperatures (plasma: 0.0397 (slope), 0.7814 (R2), cytoplasm: 0.014 (slope), 0.694 (R2)). At three values of increasing glucose levels (85.4, 158.1, and 271.8 mg/dL), the electrical conductivities of the plasma and cytoplasm decreased. These tendencies are more significant upon temperature corrections (p-values; plasma: 0.001, 0.001, cytoplasm: 0.003, 0.002). The relationships between temperature and electrical conductivity changes can thus be used for temperature corrections in blood glucose measurement.