SSSergey D. Solnushkin

Sergey D. Solnushkin

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Sergey D. Solnushkin has a total of 10 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Accelerometric startle reflex detector

    by V.O. Molodtsov, D.G. Semenov, V.YU. Smirnov, S.D. Solnushkin, V.N. Chikhman

    Problem statement. The innate reflex of startling in response to a short unexpected sound stimulus (acoustic startle reflex – ASR) is characteristic of both experimental animals and humans. Among the ASR parameters, the amplitude of muscle contraction in response to a strong stimulus and the degree of its suppression by a previous weak stimulus (prepulse) serve as markers of sensorimotor gating and are widely used in medical and experimental practice to identify mental disorders. At the same time, the high sensitivity of the recording equipment to the mechanical response, the accuracy of determining the ASR amplitude at various stimulus parameters, and a convenient service for real-time output and primary processing of results are critical characteristics of the method. Objective. To develop hardware and software for accurate quantitative automated measurements of ASR parameters in a behavioral experiment on rats. Results. The hardware module based on an accelerometric sensor and software for accurate quantitative measurement of parameters in the study of sensory-motor functions of rats at the Pavlov Institute of Physiology of the Russian Academy of Sciences have been developed. Practical significance. Hardware and software modules have been implemented to measure and register the parameters of the startling reflex with high sensitivity, and display them in real time on the screen during the experiment, which improves the quality of studying animal translational models at the preclinical research stage.

  • Image curvature assessment in the presence of distractors

    by Valeria M. Bondarko, Sergey D. Solnushkin, Valeriy N. Chikhman

    Subject of study. The mechanisms of visual perception of image curvature in the presence of additional images, referred to as distractors, were investigated. Aim of study. The aim was to describe and analyze the mechanisms of image curvature perception. Method. A series of psychophysical experiments were conducted, wherein images were analyzed, and the results were compared with those of prior studies on the perception of other visual stimuli. Main results. Curvatures for both real and interpolated images were estimated. Distortions (illusions) in the perception of image curvature in the presence of distractors were identified. Straight lines were perceived as curved, and the estimates for other stimuli were also erroneous. These illusions were more pronounced for interpolated images. The obtained data are consistent with the tilt illusion arising from the interaction between spatial-frequency channels. The observed illusions of image curvature may also be hypothetically explained by this interaction. However, a comparison with the perception of curvature of other images indicates ambiguity in the mechanisms for estimating curvature, as well as their dependence on the shape of the images and the surroundings. Practical significance. These findings can be applied in artificial neural networks for facial recognition and other images similar to those studied, as the initial processing of objects in such networks often involves filtering similar to that performed by the receptive fields of the visual cortex.

  • Measurement of startle reflex

    by V.N. Chikhman, S.D. Solnushkin, V.Yu. Smirnov, V.O. Molodtsov

    Observation and registration of the behavior of laboratory animals in response to a sound stimulus (Acoustic Startle Reflex - ASR) is one of the methods of experimental physiological research. The manifestation of this reflex is a startle - a rapid muscle twitching caused by a sudden and intense acoustic signal. Despite its relative simplicity, the magnitude of the startle response is a kind of behavioral tool that can be used to assess the physiological mechanisms of sensory motor reactions. The startle reflex parameters have been measured for a long time. One paper describes a device for measuring the acoustic startle response in mice that uses a spring-loaded arm, a strain gauge, and a polygraph. Individual startle responses were recorded using an ink recorder. Subsequently, they began to measure the reflex using electromyography. With the automation of scientific research, computerized devices are being developed. Known startle detection devices use accelerometers as sensors. These systems are characterized by excessive complexity and high cost. Purpose of our work was development of a simple device and problem-oriented software for the quantitative measurement of ASR based on the IBM PC with the Windows operating system. The floor of the experimental cage, in which the laboratory animal (white rats) is placed, is made in the form of a plastic plate mounted on four foam supports, which, in turn, are supported by four piezoelectric sensors (MakerHawk Analog Ceramic Piezo Vibration Sensor) placed in the bottom of the cage. An acoustic speaker is attached to the top of the cage to give stimulus signal. The board with electronic components is placed under the bottom of the cage. A relatively simple MD308 device has been developed and a program has been written to quantify ASR. The MD308 is based on the STM32L053C8T6 microcontroller, which provides sampling of analog signals from piezoelectric sensors into a digital code using an ADC, transferring the ADC output codes to a computer via the USB interface protocol. Simultaneously with the sampling of signals from the piezoelectric sensors, the audio signal is digitized for time reference in order to further process the recorded signals. The audio signal is formed by a computer using a standard sound card and connected to one of the ADC inputs through a high-pass filter with a signal shift to the middle of the range to convert a bipolar signal to an unipolar one. MD308 digitizes the voltage at the inputs from the piezo sensors and from the audio input in the sampling range from 0 to 2047, with a frequency of 1 kHz, i.e. on five channels, generates packets of 6 such measurements (30 values of 16 bits) and sends them to USB. This sampling frequency is quite sufficient, since the latent time of the startle reaction is about 50–300 ms. MD308 is a USB Custom HID device, data exchange with which is carried out using reports (HID_Reports). The device opens with the name "MD308". At startup, the microcontroller connects via USB to a computer and transfers the results of sampling signals from sensors and audio signal in portions of 60 bytes (ID_Report - 0x03): 6 samples in 5 channels of 2 bytes (channel 0 is the first sample, channel 1 is the first sample, ..., channel 4 is the first reading, then - channel 0 is the second reading, etc.). Since HID devices have a maximum burst rate of 1 kHz and a single burst size of maximum 64 bytes, grouping sample output values by 6 is done for the convenience of further monitoring data on the screen. The microcode for the microcontroller was developed in C++ in the IAR Embedded Workbench for ARM environment. The installation of SMD components (capacitors, resistors, etc.) on the MD308 circuit with the corresponding nominal values is made according to the approved circuit solutions. Schematic development was performed using Altium Designer CAD software. The software for the ASR reflex registration experiment based on the MD308 module is implemented in the Borland Delphi 7 environment, uses the JEDI VCL component library, which includes the TJvHidDeviceController component, which provides access to Custom HID devices. Software modules provide quantitative recording of discretized signals from four piezoelectric sensors, synthesis of an acoustic signal with specified parameters (amplitude, frequency, duration, number of sound stimuli), fixing the time of the beginning of the stimulus. Implemented dynamic display of signals on the display, their saving in the database. There are two blocks in the software - recording signals in the oscilloscope mode and displaying the preliminary processing of signals, which are stored in the database. The registration block allows you to configure the parameters of the experiment. To adjust the parameters of the sound stimulus, a group of visual components "sound" is provided. The experimenter sets the frequency of sound parcels, amplitude and duration. For testing, the buttons "start sound", "stop sound" are provided. The group of components "experiment" is intended for setting the parameters of the experiment - identification of the experiment, the number of sound bursts, the interval between sound bursts. The “start series” button starts the registration of signals and their display in real time. Upon completion of the series, the registration stops, the data can be saved in the database (button "save in the database"). The number displayed in the right corner of the "experience" group corresponds to the number of the sound message. The group of buttons at the bottom of the interface is designed to test the operation of piezoelectric sensors ("start", "stop"), set the signal display scale, and control the "sound" panel. The upper graphic field displays in real time the integrated signal of four piezoelectric sensors, the mark of the beginning of the sound stimulus in the form of a vertical lines (benchmarks). The bottom four fields display the signals...


  • Open Access

    Visual Illusions and Perception of Classical Architecture

    by V.M. Bondarko, S.D. Solnushkin, V.N. Chikhman

    We carried out psychophysical experiments to study perception mechanisms of images that are elements of building projections in ancient and classical architecture. The curvature of isolated lines and lines superimposed on a fan picture (Wundt-Hering illusion), as well as the orientation of lines in the presence of distractors with varying inclination and separation (tilt illusion) were estimated. We used the methods of constant stimuli and the forced choice procedure. The experiments were carried out on three subjects with a large number of presentations of stimuli, which made it possible to evaluate the statistical significance of the obtained dependences. The values of distortions in the illusion of Wundt-Hering (WH) and in the tilt illusion were determined. It is shown that the curvature of single lines without fan lines is estimated adequately. The analysis of the results led to the conclusion that corrections of the orientation and curvature of elements in classical architecture compensate for the distortions of visual perception. At the same time, the curvature of some elements may be due to the aesthetics of perception.

  • Open Access

    A methodological approach to study the role of memory and attention on visual perception

    by Valeriy N. Chikhman, Валерия Михайловна Бондарко, Сергей Дмитриевич Солнушкин

    Компьютерная реализация экспериментов по изучению зрительного восприятия обеспечивает большие возможности использования естественных и синтезированных изображений, а также сложного дизайна психофизических экспериментов. В работе представлены часто используемые психофизические методики по исследованию влияния на зрительное восприятие механизмов памяти и внимания, реализованные с использованием компьютерных технологий. Механизмы памяти изучали путем сравнения результатов ответов на последовательное и одновременное предъявления одних и тех же стимулов в задаче оценки кривизны реальных и интерполированных линий. При одновременном предъявлении в отличие от последовательного была выявлена иллюзия выпрямления интерполированных линий и более низкие пороги различения кривизны. Влияние механизма внимания оценивали путем сопоставления результатов выполнения одинарной и двойной задач. В двойной задаче от наблюдателей требовалось опознать как форму тестового объекта, так и форму дистрактора, расположенного на разном расстоянии от теста. Стимулы имели низкий контраст и короткое время предъявления. Предполагалось, что выполнение двойной задачи скажется на перераспределении внимания, что затруднит опознание теста. Однако достоверного ухудшения опознания тестового стимула в двойной задаче по сравнению с одинарной не наблюдалось. Достоверно уменьшилось только число неслучайных ошибок. Расстояния дистрактора до теста, на которых выявлено ухудшение распознавания, намного превосходили значения, полученные в подобных экспериментах, но с использованием других условий наблюдения. Влияние механизма внимания в обеих задачах проявилось как более сильное ухудшение опознания при использовании дистракторов, аналогичных по форме с тестами, но отличающихся ориентацией. Показано влияние методического подхода и дизайна эксперимента на получаемые результаты.


  • Quantitative evaluation of the functional activity in multilayered brain structures using histological sections

    by S. V. Alekseenko, S. D. Solnushkin, V. N. Chikhman

    Subject of study. We develop an algorithm and software to estimate optical density as a correlate of neural activity in multilayered brain structures. Aim of study. We develop a method and program algorithm for quantitative evaluation of the optical density in the layers of neural structures from images of histological brain preparations that correlates with the functional activity of the cells. Method. Optical density was measured locally in successive areas of a layer or several layers of the neural structure, which are curvilinear-shaped in the brain slices. An expert researcher selects the trajectory of optical density measurement in the digitized image of the slice in an interactive mode. The results of density measurements were plotted in an orthogonal coordinate system. Capabilities enabling automated curve smoothing, extremum seeking, and calculation of distances between extrema were developed. Results. An algorithm for implementing the developed program is presented. The successive stages of operation are illustrated through the evaluation of the optical density in the visual cortex layer from an image of a brain slice as an example. In addition, the evaluation results of the optical density in layers of a lateral geniculate body are presented. Practical significance. The developed method and program algorithm are required for reconstructing the functional activity of the curved layers of different brain structures to investigate and simulate the organization patterns of the neural networks of the human brain.


  • Open Access

    Experiences in automating physiological experiments

    by Valeriy N. Chikhman, Сергей Дмитриевич Солнушкин, Vladimir O. Molodtsov

    В статье описывается опыт разработки, реализации и внедрения систем автоматизации физиологического эксперимента, накопленный в Институте физиологии им. И. П. Павлова РАН на протяжении последних десятков лет. Рассмотрены примеры создания аппаратных средств измерения сигналов, преобразования их в цифровую форму, ввода и накопления в памяти ЭВМ с целью их применения в составе ЭВМ общего назначения, а также в комплексе появлявшихся по мере развития вычислительной техники миниЭВМ, микроЭВМ, ПЭВМ и заказных проблемно-ориентированных аппаратных модулей для автоматизации физиологических экспериментов по основным направлениям физиологических научных исследований, проводимых в ИФ РАН. Освещены вопросы разработки концепции проблемно-ориентированного программного обеспечения, использования системы управления базами данных (СУБД), графического отображения результатов. Рассмотрен ряд примеров разработки аппаратных и программных модулей для различных физиологических экспериментов. В частности, для использования в системе оценки функционального состояния дыхательных мышц человека, исследования сократительной функции сосудов и узлов кровеносной и лимфатической систем, для контроля изменения частоты импульсной активности нейронов, для организации управляемого электрического воздействия на лабораторное животное в поведенческих экспериментах, для измерения параметров жизнедеятельности лабораторных животных в экспериментах по исследованию механизмов висцеральной боли.


  • Open Access

    Software Package for Special Teaching and Testing of Children with Hearing and Speech Impairments

    by E.I. Stolyarova, N.Y. Belova, S.D. Solnushkin, V.N. Chikhman

    The paper presents a description of the software package (code name “Speech-Assistant”), intended for use in special education and testing of children with hearing and speech impairments, causing difficulties in mastering reading and writing skills. An attempt has been made to create a software package capable of sufficiently providing both the solution of various research problems and the expansion of opportunities for increasing the effectiveness of teaching and developmental lessons in practical application in the educational process. When designing it, the wishes of practicing special teachers (defectologists) and the results of studies of auditory perception and speech skills in children with hearing and speech disorders, carried out in the laboratory of speech psychophysiology of the Pavlov Institute of Physiology RAS. The complex includes three thematic blocks: “Learn to listen”, “Learn to read”, “Exercises”. The programs of the complex provide the convenience of the teacher's independent preparation of didactic material for the planned lessons, the implementation of a wide range of educational tasks, and their preservation for repeated use. In the process of conducting lessons, objective indicators of assignments are recorded, a digital archive of the training or testing results is automatically generated in the database in the form of personalized excel and wav-files. The article presents materials that illustrate the capabilities of the complex when performing tasks from the above thematic blocks. The approbation of the complex working was carried out within the framework of training sessions in 5-9th classes of a specialized school.