CCChung-Lung Chen

Chung-Lung Chen

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Chung-Lung Chen has a total of 42 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Capillary transfer: Numerical study of how topology affects the fluid flow rate into a planar microstructure with pseudopotential multiphase Lattice-Boltzmann method

    by Robin Pham, Sheng Wang, Heng-Chieh Chien, Chung-Lung Chen

    We investigate how topology impacts capillary action with the hope of aiding future thermal engineering decisions. Heat pipes and their two-dimensional variant, vapor chambers are essential components in electronics cooling. With thin-film evaporation as the driving force for such high-heat-flux movers, studies have been done to optimize the thermal performance of different designs. However, the fundamental problem of liquid transportation needs to be addressed exclusively: evaporation can only work as long as the new liquid is continuously being replaced. The device achieves this by the capillary process (or wicking) through the thermal ground (or wicks): a configuration of microstructures attached to the device's walls. Some planar topologies of the structure allow for consistent but slower mass feeding; others offer higher bandwidth but with local flow hindrance, creating a pulsating tendency; certain conditions would even block the capillary flow. Surveying the capillary performance of different two-dimensional designs of the thermal ground, we encounter a topological factor that correlates with this mass transfer rate. We incorporate in the factor the wick's width, its height, and the gap between one microstructure to another. An energy model is studied to explain the underlying influence of the structure topology, while Lattice-Boltzmann method is used to evaluate the capillary dynamics inside the thermal ground. With ultra-thin applications in mind, the paper looks at the length scales of micrometers with a wick height of 50 μm. Overall, we find that tightly packed structures pull the most liquid in the same amount of time; however, we find that two core constraints need to be met: sufficient clearance between structures and freedom of mobility.


  • Activating Bubble’s Escape, Coalescence, and Departure under an Electric Field Effect

    by Run Yan, Robin Pham, Chung-Lung Chen

    In this paper, we present the results of applying an electric field to activate bubbles’ escape, coalescence, and departure. A simple electrowetting-on-dielectric device was utilized in this bubble dynamics study. When a copper electrode wire inserted into deionized water was positioned on one side of single or multiple bubbles, the bubble tended to continuously escape from its initial position as the voltage was turned on. Contact angle imbalance at different sides of the bubble was observed, which further promoted the bubble’s escape. An analysis model with an electromechanical framework was developed to study the charging time difference on two sides of the bubble, which generated a wettability gradient and capillary force to propel it away from the electrode. Sine, ramp, and square alternating current waveforms with 60 V amplitude and 2 Hz frequency were tested for comparison. It was shown that all waveforms promoted the bubble’s escape; the square wave shape manifested the farthest escape capability, followed by sine and ramp waves. An upper view of several bubbles aligning in triangle, square, pentagon, and hexagon shapes demonstrated that the bubbles tended to move outward when the electrode is placed at the geometric centers. Experiments with an electrode on one side and several bubbles positioned in a line were conducted. In these cases, the bubbles closer to the electrode reacted faster than those farther from the electrode, resulting in coalescence. Once the bubble size became larger, it departed either by overcoming the disjoining pressure in a thin film of water or via the buoyancy force in a thick film of water. Controlling bubble dynamics by the electric field, including escape, coalescence, and departure provides an active and reversible approach to move bubbles or increase departure frequency in many fluid mechanics and heat transfer studies.


  • Condensation Droplet Distribution Regulated by Electrowetting

    by Run Yan, Chung-Lung Chen

    This paper presents a visualization of condensation droplet distribution affected by the electrowetting-on-dielectric (EWOD) approach. A single-side double-layer-electrode design (grid wire, thin wire, and thick wire) and coplanar-electrode design (zigzag) are discussed. Side-by-side experiments with applied 40 V DC electric potential are carried out to compare droplet distribution between identically designed charged and uncharged devices. The uncharged devices show a random droplet distribution, whereas charged devices have a regulated distribution based on the designed patterns. As droplets on the electrode boundaries become larger, they are likely to slide away and stay in electrode-free regions. The droplets “sit” inside the grid wires and distribute vertically along thin and thick wires. On the coplanar-electrode zigzag device, droplets are distributed vertically. The charged surfaces lead to a faster droplet growth rate and more dispersed droplet distribution. This phenomenon accelerates the shedding frequency of the droplets and frees up more areas for small droplets to nucleate and grow. The first shedding moment of the charged surfaces occurs earlier than the uncharged ones for all types of EWOD devices. The detected droplet shedding diameter ranges from 1.2 mm to 2.5 mm in this study. The number of large droplets is found greater on the charged devices compared with the uncharged devices and theoretical model. The work presented in this paper introduces a novel approach to actively influence droplet distribution on microfabricated condensing surfaces and indicates great potential for improving the condensation heat transfer rate via EWOD.


  • Enhanced water capture induced with electrowetting-on-dielectric (EWOD) approach

    by Run Yan, Thomas S. McClure, Ibrahem H. Jasim, Akshay Kumar Reddy Koppula, Sheng Wang, Mahmoud Almasri, Chung-Lung Chen

    An electrowetting-on-dielectric (EWOD) device that enhances water capturing capability for condensation applications is presented. A single planar EWOD device is fabricated for testing and placed in a high-humidity environment under mist flow. By applying an electric field to portions of the device, the wettability of the affected areas is altered from hydrophobic to hydrophilic, which promotes droplet nucleation and growth, thereby improving water capturing capability. The results of this study demonstrate that droplet coalescence is appreciably improved at the moments of plugging and unplugging DC voltage, which induces wipe-down events (when a droplet drips down the surface and removes all droplets underneath it). The improvement in water capturing capability under DC voltages of 20 V, 40 V, and 60 V is also investigated both by comparing the mass of water collected on uncharged and charged devices during the same testing period and by using an image processing approach to track changes in droplet area coverage over time. The EWOD effect was shown to improve water capturing capability for the 20 V, 40 V, and 60 V cases by 138.96%, 171.87%, and 220.43%, respectively. These results are of great significance as they indicate a strong possibility for improvement in water harvesting applications.


  • Bio-inspired self-agitator for convective heat transfer enhancement

    by Zheng Li, Xianchen Xu, Kuojiang Li, Yangyang Chen, Zhaoqing Ke, Sheng Wang, Hsiu-Hung Chen, Guoliang Huang, Chung-Lung Chen, Chien-Hua Chen

    Convective heat transfer plays an important role in both the fundamental research and the development of high-performance heat exchangers. Inspired by blades of grass vibrating in the wind, we developed a self-agitator for convective heat transfer enhancement. Because of fluid-structure interactions, the agitator, with self-sustained vibration, can generate strong vortices to significantly break the thermal boundary layer and improve fluid mixing for enhanced convective heat transfer. In particular, we establish a methodology to link the vorticity field at a preferred frequency to the optimal improvement in the convective heat transfer. To identify the self-agitator preferred frequency, mode analysis is performed with simulation results using dynamic mode decomposition. Experimental results are also obtained to further validate the proposed approach. These results show that the proposed self-agitator design can improve the convective heat transfer by 120% in a conventional heat exchanger without additional pumping power requirements and can achieve a Nusselt number of up to 30 within the laminar flow region, which is improved by 200% with the same Reynolds number compared to the clean channel.


  • Towards enhanced bubble detachment within a thin liquid film by electrowetting with voltage modulation

    by Sheng Wang, Brian J. Hernan, Chung-Lung Chen

    This paper extends our previous bubble actuation study using a simple constant voltage by including the oscillating effect created by voltage modulation. Rather than normal contact angle change due to the constant voltage, voltage modulation exhibits preferable characteristics of periodical contact angle variation which is proved to be helpful for bubble detachment within a thin liquid film. Different waveform and frequency modulations were evaluated to acquire an optimal signal input for the purpose of inducing the maximum oscillation effects with which bubble detachment in a thin liquid film can be enhanced. The thick liquid film results show that the square waveform coupled with a frequency of 1 Hz allows for maximum contact angle change scope and induces the largest vertical bubble velocity. With the optimal signal, the tests of bubble detachment within a thin liquid film were conducted and characterized. Three different bubble detachment modes were observed and classified as follows: direct detachment, delayed detachment, and non-detachment. The actuation mechanism of the electrowetting effect on the bubble behavior within a thin liquid film was analyzed. The dimensionless parameter, Weber number, was used to characterize the bubble deformation. A high-speed frame analysis shows that a Weber number greater than 0.5 × 10−3 is necessary to break the energy barrier of the ultra-thin film and achieve the direct detachment mode. It is expected that a proper electrowetting actuation mechanism causing a relatively large Weber number can effectively enhance the bubble detachment within a thin liquid film which will provide promising applications to improve two-phase heat transfer.