Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Jacopo Colombo has a total of 44 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Impact of Professional Hygiene Instruments on the Roughness of Implant Surfaces: An In Vitro Analysis

    by Jacopo Colombo, Francesca Baldi, Paola Gavoglio, Giulia Marchisio, Domenico Baldi

    Introduction: This study highlights the importance of maintaining dental implants, particularly in the context of peri-implantitis. It emphasizes the need for dental hygienists to choose appropriate instruments that will not damage implant surfaces while effectively cleaning them. Materials and Methods: The research involved in vitro tests using 4 ultrasonic inserts for peri-implant mechanical instrumentation on one machined and one etched healing abutment, with a focus on how these instruments affect surface roughness. For each insert, four surface roughness measurements were recorded on each abutment. The data were then analyzed in two separate designs, one for the machined abutments and one for the etched abutments. The significance of the factors was determined by analyzing them using an ANOVA test. Results: The study found significant effects of surface treatment and instrument type on surface roughness parameters. Instrumentation tended to alter the roughness of machined surfaces more than etched ones, with notable differences in performance among the various inserts. Discussion: The results suggest that surface treatment has a more substantial impact on roughness than the choice of instrument. Future studies are encouraged to explore other parameters related to bacterial biofilm retention and the potential release of material from non-metallic inserts. Conclusions: Key findings include that surface treatment significantly influences surface roughness and that specific instruments can either increase or decrease roughness based on the type of surface.

  • Open Access

    Usefulness of the Magnetodynamic Mallet in Tooth Extraction: A Case Series

    by Domenico Baldi, Francesca Baldi, Federica Giordano, Luisa De Giorgis, Francesco Bagnasco, Andrea Tancredi Lugas, Maria Menini, Jacopo Colombo

    Background: Tooth extraction techniques have been refined over the years in order to be less traumatic and to better preserve alveolar bone. A recently introduced extraction method involves the use of the Magnetic Mallet®, which allows clinicians to be more precise and perform extractions faster. Moreover, the instrument enables the procedure to be less traumatic for patients. The aim of the present study was to clinically evaluate whether extractions performed using the Magnetic Mallet® can lead to less buccolingual bone resorption. Methods: Between February 2023 and June 2023, nine patients with an average age of 62 years underwent 29 extractions using the Magnetic Mallet®. Sectorial CBCTs were performed in order to measure buccolingual bone thickness at time 0 (T0, before extraction) and 3 months after extraction (T3M). All the extractions were performed by two different expert operators exclusively using the Magnetic Mallet®. For statistical analysis, a two-sample t-test was performed to determine the difference between the measurements taken at T0 and those taken at T3M in the 29 dental elements and the difference in bone loss between the surgeries conducted by the two clinicians. Results: A total of 22 teeth were extracted in the upper jaw and 7 in the lower jaw. The average degree of mobility was 1. The average degree of force impressed by the instrument to extract the teeth was 2, while the average frequency of blows administered was 7. The average time taken for the extractions was 3½ min. After 3 months, the mean buccolingual bone resorption was 1.54 mm (SD: ±). The difference in buccolingual bone thickness between T0 and T3 was significant at an alpha significance level of 0.01. No difference in bone resorption was found between the surgeries conducted by the two clinicians. Conclusions: The use of the Magnetic Mallet® results in bone loss in the buccolingual direction comparable with existing data in the literature on healing the post-extraction socket. This tool seems to be predictable in producing the same results between different operators.


  • Open Access

    Usefulness of Magnetodynamic Mallet in Tooth Extraction

    by Domenico Baldi, Francesca Baldi, Federica Giordano, Luisa De Giorgis, Francesco Bagnasco, Andrea Tancredi Lugas, Maria Menini, Jacopo Colombo

    Tooth extraction techniques have been refined over the years in order to be less traumatic and better preserve alveolar bone. A recently introduced extraction method involves the use of the Magnetic Mallet®, which allows the clinician to be more precise, faster and less traumatic. The aim of the present study was to clinically evaluate whether extractions performed by means of the Magnetic Mallet® can lead to less bucco-lingual bone resorption. Between February 2023 and June 2023, 9 patients with an average age of 62 years underwent 29 extractions using the Magnetic Mallet®. Sectoral CBCTs were performed in order to measure bucco-lingual bone thickness at time 0 (T0, before extraction) and 3 months after extraction (T3M). All the extractions were performed by 2 different expert operators using exclusively the magnetic mallet. For statistical analysis, a two-sample t-test was performed between the measurements taken at T0 and those taken at T3M in the 29 dental elements and between the difference in bone loss among the 2 different clinicians. 22 teeth were extracted in the upper jaw and 7 in the lower jaw. The average degree of mobility was 1. The average degree of force impressed by the instrument to extract the teeth was 2, while the average frequency of blows administered was 7. The average time taken for the extractions was 3½ minutes. After 4 months, the mean bucco-lingual bone resorption was 1.54 mm (SD: +-). The difference of bucco-lingual bone thickness between T0 and T3 was significant at an alpha significance level of 0.01. No difference were found in bone resorption based on the clinician. The use of the Magnetic Mallet® during tooth extraction led to less bucco-lingual bone resorption in the 3 months following dental extraction, compared to the traditional use of manual hammers, chisels and levers.


  • Open Access

    Correction: Influence of dental implant site preparation method on three aspects of the site: magnetodynamic mallet versus conventional drill

    by Domenico Baldi, Jason Motta Jones, Enrico Lertora, Chiara Burgio, Andrea Tancredi Lugas, Gianmario Schierano, Jacopo Colombo

    Aim: Magnetodynamic surgery has assumed increasing importance in recent years. The purpose of the present study was to compare in vitro, using dry porcine ribs, two methods of dental implant site preparation (conventional drill and magnetic mallet) on three aspects of the site. These were the difference between the diameter of the site and the diameter of the last drill used (an index of the accuracy of the preparation), the weight loss of the specimen on which the site was prepared (index of the bone loss in the site), and the change of temperature at the site (an index of the change to the material at the site). Methods: Eight preformed pork ribs were chosen for the study. Four implant preparations were made on each rib, two with Magnetic Mallet (Meta Ergonomica, Turbigo, Italy) and two with traditional drills. Each bone sample was weighed before and after implant site preparation in order to calculate the amount of bone lost during preparation. The diameter of preparations was analyzed with the aid of an optical microscope (MZ6, Leica, Wetzlar, Germany) connected to a dedicated measurement software. For the evaluation of the temperature, eight preparation sites were marked. In correspondence of each preparation site, on the opposite side of the rib, a hole was made for the thermocouple (HI 91530K, Hanna Instruments, Padova, Italy). During the preparations, the thermocouple was kept inserted inside the control hole to record the temperature variation. The results were analyzed using appropriate statistical methods, such as the Kolmogorov-Smirnoff test and the Wilcoxon test. Results: It was found that mallet drill provided significantly higher accuracy of preparation, lower amount of damage at the site, and less change to the porcine rib test material at the preparation site. Conclusions: A possible clinical implication of this finding is discussed.


  • Influence of dental implant site preparation method on three aspects of the site: magnetodynamic mallet versus conventional drill

    by Domenico Baldi, Jason Motta Jones, Enrico Lertora, Chiara Burgio, Andrea Tancredi Lugas, Gianmario Schierano, Jacopo Colombo

    Aim: Magnetodynamic surgery has assumed increasing importance in recent years. The purpose of the present study was to compare in vitro, using dry porcine ribs, two methods of dental implant site preparation (conventional drill and magnetic mallet) on three aspects of the site. These were the difference between the diameter of the site and the diameter of the last drill used (an index of the accuracy of the preparation), the weight loss of the specimen on which the site was prepared (index of the bone loss in the site), and the change of temperature at the site (an index of the change to the material at the site). Methods: Eight preformed pork ribs were chosen for the study. Four implant preparations were made on each rib, two with Magnetic Mallet (Meta Ergonomica, Turbigo, Italy) and two with traditional drills. Each bone sample was weighed before and after implant site preparation in order to calculate the amount of bone lost during preparation. The diameter of preparations was analyzed with the aid of an optical microscope (MZ6, Leica, Wetzlar, Germany) connected to a dedicated measurement software. For the evaluation of the temperature, eight preparation sites were marked. In correspondence of each preparation site, on the opposite side of the rib, a hole was made for the thermocouple (HI 91530K, Hanna Instruments, Padova, Italy). During the preparations, the thermocouple was kept inserted inside the control hole to record the temperature variation. The results were analyzed using appropriate statistical methods, such as the Kolmogorov-Smirnoff test and the Wilcoxon test. Results: It was found that mallet drill provided significantly higher accuracy of preparation, lower amount of damage at the site, and less change to the porcine rib test material at the preparation site. Conclusions: A possible clinical implication of this finding is discussed.


  • Open Access

    Roughness and SEM Analysis of Manual and Ultrasonic Instrumentation over Different Crown Materials for Dental Implants Restorations

    by Domenico Baldi, Jacopo Colombo, Paola Gavoglio, Luisa De Giorgis, Franco Motta, Andrea Lugas, Enrico Lertora, Gianmario Schierano

    The use of new prosthetic materials makes it necessary to establish adequate hygienic protocols. It was decided to make prosthetic crowns from four different materials: composite, lithium disilicate, metal ceramic, and zirconium, and to evaluate the effects on the surfaces of four different instruments through SEM and roughness analysis: manual steel curette, manual titanium curette, ultrasonic steel insert, and ultrasonic peek insert. Forty crowns were made, ten of each type of material. For each material, five crowns were manually instrumented with steel inserts (curette 11-12, PDT, Missoula, MT, USA) and titanium (Wingrove 3-4, PDT, Missoula, MT, USA) on the lingual and buccal surfaces, respectively, and the other five crowns were instrumented with an ultrasonic peek insert (ICS-IC1, Mectron, Carasco, Italy) on the buccal surface and steel (PS, EMS, Nyon, Switzerland) on the lingual surface. At this point, surface roughness analysis was carried out. The data were analyzed with a Kolmogorov–Smirnov test. Therefore, it was decided to conduct two analyses with a Kruskal–Wallis test and Bonferroni post hoc test. Then, the instrumented crowns were analyzed by SEM. The analysis of the data shows that the highest average roughness was within the composite group, while the best material appeared to be disilicate. Significant differences existed between the groups, between the materials, and between the different instruments (p-value < 0.05). In the qualitative analysis carried out by SEM, the classic steel insert eliminated the residues of golden finishing. The peek insert created alterations on all tested surfaces. The steel curette did not create particular problems, with the exception of zirconium, where it was possible to observe some scratch lines. Instrumentation with the titanium curette created deeper incisions than the steel curette in the composite and disilicate. The best results came from the ultrasonic steel insert, while the best material appeared to be disilicate.


  • Open Access

    Efficacy of Instruments for Professional Oral Hygiene on Dental Implants: A Systematic Review

    by Domenico Baldi, Luisa De Giorgis, Maria Menini, Franco Motta, Jacopo Colombo

    Professional oral hygiene is fundamental to prevent peri-implant disease. Appropriate instruments should be used in patients with restorations supported by dental implants: they should be effective in deposits removal without damaging the implant components surface. The aim of the present study is to investigate and summarize the results regarding the efficacy of oral hygiene techniques described in the literature in the last 10 years in patients rehabilitated with dental implants not affected by perimplantitis. The present systematic review was conducted according to guidelines reported in the indications of the Preferred Reporting Items for Systematic Review and Meta-Analysis (PRISMA). The focused question was: “Which are the most effective instruments for professional oral hygiene on implants not affected by perimplantitis?”. The initial database search yielded a total of 934 entries found in PubMed®/MEDLINE and Cochrane Library. After full text review and application of the eligibility criteria, the final selection consisted of 19 articles. The risk of bias of included studies was assessed using the Newcastle Ottawa scale (NOS) and the Cochrane Handbook for Systematic Reviews of Interventions. Curette, scalers and air polishing were the devices most frequently investigated in the included studies. In particular, glycine powder air polishing appeared to be significantly effective in reducing peri-implant inflammation and plaque around implants. The application of the more recent erythritol powder air polishing also yielded good clinical outcomes. Further studies are needed to improve the knowledge on the topic in order to develop standardized protocols and understand the specific indications for different types of implant-supported rehabilitations.


  • Open Access

    Biomolecular, Histological, Clinical, and Radiological Analyses of Dental Implant Bone Sites Prepared Using Magnetic Mallet Technology: A Pilot Study in Animals

    by Gianmario Schierano, Domenico Baldi, Bruno Peirone, Mitzy Mauthe von Degerfeld, Roberto Navone, Alberto Bragoni, Jacopo Colombo, Riccardo Autelli, Giuliana Muzio

    Background. A new instrumentation exploiting magneto-dynamic technology (mallet) proposed for implant site preparation was investigated. Methods. In the tibias of three minipigs, two sites were prepared by mallet and two by drill technique. Primary stability (ISQ) was detected after implant positioning (T0) and at 14 days (T14). X-rays and computed tomography were performed. At T14, bone samples were utilized for histological and biomolecular analyses. Results. In mallet sites, histological evaluations evidenced a significant increase in the newly formed bone, osteoblast number, and a smaller quantity of fibrous tissue. These results agree with the significant BMP-4 augmentation and the positive trend in other osteogenic factors (biological and radiological investigations). Major, albeit IL-10-controlled, inflammation was present. For both techniques, at T14 a significant ISQ increase was evidenced, but no significant difference was observed at T0 and T14 between the mallet and drill techniques. In mallet sites, lateral bone condensation was observed on computed tomography. Conclusions. Using biological, histological, clinical, and radiological analyses, this study first shows that the mallet technique is effective for implant site preparation. Based on its ability to cause osseocondensation and improve newly formed bone, mallet technology should be chosen in all clinical cases of poor bone quality.


  • Pulp vitality during ultrasonic tooth preparation. Part 2

    by Domenico Baldi, Jacopo Colombo, Claudio Stacchi, Maria Menini, Amalia Oronos, Paolo Pera

    BACKGROUND: Ultrasonic devices have a lot of dental application specially in hygiene and surgery. However there are some disadvantages like cut slowness and heat production. Prosthodontics application is less investigated. In particular the heat production could be an important factor for the clinician. In fact more than 5.5 degrees C temperature increasing could determine pulp necrosis during tooth preparation. The aim of this study is to investigate the increasing of temperature during finishing line repositioning and polishing phases using ultrasounds inserts and to verify if it remains within the limit of 5.5 degrees C. METHODS: A sample of 32 human molars (extracted for periodontal reasons) was selected. The teeth were endodontically treated and prepared with burs in order to obtain a prosthetic round chamfer preparation, leaving the apical portion pervious for inserting the thermocouple probe. Then, they were inserted in plaster cubes up to the cement-enamel junction. A wall has been selected for each tooth for margin repositioning and finishing and prepared with the piezoelectric instrument (Multipiezo Touch with TipHolder DB2, Mectron, Carasco, Genoa, Italy). A mechanical arm was used to standardize the operator-dependent parameters. These parameters were: the pressure exerted on the dental wall, the cutting length and the time required for margin repositioning and finishing. The test phase consisted in a first stage of margin repositioning using an regular ultrasound tip with a diamond grain of 120 micron (DB120, Mectron, Carasco, Italy) (group 1), followed by a second finishing step conducted by a extra fine ultrasound tip with a diamond grain of 60 micron (DB60, Mectron, Carasco, Italy) (group 2). Each test lasted 60 seconds: this was the time that the mechanical arm needed to accomplish 32 rides. During these stages the intrapulpal temperature has been recorded thanks to a thermocouple. The obtained temperature data were analyzed by Kruskal-Wallis test and Mann-Withney post-hoc test, without Bonferroni correction (P<0.001). RESULTS: The average pulpal temperature increase was 4.65 degrees C with a standard deviation of 0.99 degrees C for the DB 120 ultrasonic tip and 5.40 degrees C with a standard deviation of 0.84 degrees C for the DB 60 ultrasonic tip. However, neither of the instruments reach the medium critical level of 5.5 degrees C reported in the literature, there are some single values who exceed it. There is statistically significant difference using tips with different granulometries within the two groups (P value =0.013). CONCLUSIONS: Ultrasonic tools are very performing to achieve results in repositioning and polishing of prepared tooth. The in-vitro analysis show that the pulp temperature increasing remains within the safe limits literature shows. It is important underline the polishing phase is the most critical and the clinicians have to pay attention to irrigation and pression to avoid pulp damages. Additional clinical studies have to be performed to confirm these results.


  • Clinical osseointegration of bone level implants with conical shape and textured surface with low primary stability

    by Domenico Baldi, Jacopo Colombo, Simone Verardi, Alberto Rebaudi, Federico Rebaudi, Christian Makary

    BACKGROUND: Evidence shows lower chance for osseointegration of implants without sufficient primary stability. The present retrospective study observed bone level conical screw implants with textured surface without primary stability. METHODS: Twenty-six Stark conical screw implants, with V-Blast (Vanish Blast) surface treatment were placed with low primary stability, (insertion torque lower than 10 N/cm and visible mobility at lateral load of 250 g). A soft diet was prescribed. osseointegration was assessed applying 30 Ncm of reverse torque 6 months after placement. RESULTS: The 26 implants that did not achieve primary stability still had a survival rate of 96% after the observation period and were classified as successful according with ICOI Pisa consensus conference success, survival, failure classification.96% of the implants showed clinical osteointegration and were successfully restored. After 12 months, all implants remained functional. CONCLUSIONS: It can be concluded that bone-level implants with V-Blast surface in absence of functional loading are able to achieve osteointegration, even with low primary stability.