Mykhailo M. Kozulya
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Mykhailo M. Kozulya has a total of 64 co-authors. Here are the top co-authors by number of shared publications:
- Volodymyr E. Moiseenko
Institute of Plasma Physics, National Science Center “Kharkiv Institute of Physics and Technology
7 shared publications - Yurii V. Kovtun
Institute of Plasma Physics of the National Science Center “Kharkiv Institute of Physics and Technology
5 shared publications - A. V. Lozin
Institute of Plasma Physics
4 shared publications - Alexander Krasyuk
Institute of Plasma Physics of the National Science Center “Kharkiv Institute of Physics and Technology 1 ,” 61108 Kharkiv, Ukraine
4 shared publications - Anatoliy Shapoval
Institute of Plasma Physics of the National Science Center “Kharkiv Institute of Physics and Technology 1 ,” 61108 Kharkiv, Ukraine
4 shared publications - Demian Baron
Institute of Plasma Physics
4 shared publications
Latest Publications
- 29 April 2025
- Published by Taylor & Francis in Fusion Science and Technology
- Vol. 81 (6) , 530-541
Glow Discharge Cleaning on the Uragan-2M Stellarator
- 29 April 2025
- Published by Taylor & Francis in Fusion Science and Technology
- Vol. 81 (6) , 530-541
Glow Discharge Cleaning on the Uragan-2M Stellarator
- Open Access
- 1 April 2024
- Published by AIP Publishing in Physics of Plasmas
- Vol. 31 (4)
ICRF production of plasma with hydrogen minority in Uragan-2M stellarator by two-strap antenna
The experiments on medium-size stellarator Uragan-2M (U-2M) in Kharkiv, Ukraine, are carried on in support of the Wendelstein 7-X (W7-X) experimental program. The scenario ion cyclotron frequency range (ICRF) plasma production at the hydrogen minority regime had been experimentally tested on U-2M and was qualified at the Large Helical Device (LHD). The paper presents the results of further research on the ICRF plasma production. The ICRF discharge studies were carried out in a H2 + He mixture with a controlled hydrogen concentration ranging from few percents to 75%. The two-strap like antenna mimicks the W7-X antenna operated in monopole phasing. The applied RF power was in the range of ∼100 kW. Relatively dense plasma of up to Ne ∼ 1019 m−3 was produced near the first harmonic of the hydrogen cyclotron frequency. The maximum temperature of the electrons and ions was not more than a few tens of electron volt. The characteristic features of RF plasma production and the propagation of electromagnetic waves in the experimental conditions are discussed. The experiments on U-2M and LHD indicate that the minority scenario of ICRF plasma production appears to be scalable and could be used in large stellarator machines. This is, in particular, important for the future experiments ICRF production of target plasma in W-7X in conditions where electron cyclotron resonance heating start-up is not possible.
- 1 April 2024
- Published by AIP Publishing in Physics of Plasmas
- Vol. 31 (4)
Open AccessICRF production of plasma with hydrogen minority in Uragan-2M stellarator by two-strap antenna
The experiments on medium-size stellarator Uragan-2M (U-2M) in Kharkiv, Ukraine, are carried on in support of the Wendelstein 7-X (W7-X) experimental program. The scenario ion cyclotron frequency range (ICRF) plasma production at the hydrogen minority regime had been experimentally tested on U-2M and was qualified at the Large Helical Device (LHD). The paper presents the results of further research on the ICRF plasma production. The ICRF discharge studies were carried out in a H2 + He mixture with a controlled hydrogen concentration ranging from few percents to 75%. The two-strap like antenna mimicks the W7-X antenna operated in monopole phasing. The applied RF power was in the range of ∼100 kW. Relatively dense plasma of up to Ne ∼ 1019 m−3 was produced near the first harmonic of the hydrogen cyclotron frequency. The maximum temperature of the electrons and ions was not more than a few tens of electron volt. The characteristic features of RF plasma production and the propagation of electromagnetic waves in the experimental conditions are discussed. The experiments on U-2M and LHD indicate that the minority scenario of ICRF plasma production appears to be scalable and could be used in large stellarator machines. This is, in particular, important for the future experiments ICRF production of target plasma in W-7X in conditions where electron cyclotron resonance heating start-up is not possible.
- 26 June 2022
- Published by Springer Nature in Journal of Fusion Energy
- Vol. 41 (2) , 1-7
Plasma Production in ICRF in the Uragan-2M Stellarator in Hydrogen–Helium Gas Mixture
- 26 June 2022
- Published by Springer Nature in Journal of Fusion Energy
- Vol. 41 (2) , 1-7
Plasma Production in ICRF in the Uragan-2M Stellarator in Hydrogen–Helium Gas Mixture
- 9 August 2021
- Published by National Academy of Sciences of Ukraine (Co. LTD Ukrinformnauka) (Publications) in Science and innovation
- Vol. 17 (4) , 33-43
Development of Technology for Vacuum Surface Conditioning by RF Plasma Discharge Combined With DC Discharge
Introduction. It is important to decrease light and heavy impurities influxes towards the plasma volume during the high temperature plasma experiments in fusion devices. This is why the conditioning of the wall inner vacuumsurfaces is a basic part of the fusion device operation.Problem Statement. The conventional inner vacuum chamber surface conditioning methods has a significant drawback: sputtering materials in a vacuum chamber. The inner vacuum surfaces can be also conditioned with radio-frequency (RF) discharge plasma, but the conditioning effectiveness is limited by low ion energy.Purpose. The purpose of this research is to develop vacuum surface conditioning technology by the radio frequency plasma combined with DC discharge. Materials and Methods. The noncontact passive method of optical plasma spectroscopy has been used to estimate ion plasma composition. The stainless steel outgassing has been determined in situ with the thermodesorption probe method. The sputtering of the samples has been measured with the weight loss method.Results. The studies of combined discharge have shown that: the anode voltage of combined discharge is lower than in case of the glow discharge; the stainless steel 12Kh18N10T erosion coefficient is about 1.5 times less in thecase of combined discharge than in the glow one; the thermal desorption diagnostic of wall conditions in the DSM-1 has shown better efficiency with the combined discharge as compared with the glow discharge. Theproposed technology is an original one and has no analogs.Conclusions. The reported research results have shown good prospects for the combined discharge usage for plasma walls conditioning and opportunities for using the combined discharge technology for big fusion machines.
- 9 August 2021
- Published by National Academy of Sciences of Ukraine (Co. LTD Ukrinformnauka) (Publications) in Science and innovation
- Vol. 17 (4) , 33-43
Development of Technology for Vacuum Surface Conditioning by RF Plasma Discharge Combined With DC Discharge
Introduction. It is important to decrease light and heavy impurities influxes towards the plasma volume during the high temperature plasma experiments in fusion devices. This is why the conditioning of the wall inner vacuumsurfaces is a basic part of the fusion device operation.Problem Statement. The conventional inner vacuum chamber surface conditioning methods has a significant drawback: sputtering materials in a vacuum chamber. The inner vacuum surfaces can be also conditioned with radio-frequency (RF) discharge plasma, but the conditioning effectiveness is limited by low ion energy.Purpose. The purpose of this research is to develop vacuum surface conditioning technology by the radio frequency plasma combined with DC discharge. Materials and Methods. The noncontact passive method of optical plasma spectroscopy has been used to estimate ion plasma composition. The stainless steel outgassing has been determined in situ with the thermodesorption probe method. The sputtering of the samples has been measured with the weight loss method.Results. The studies of combined discharge have shown that: the anode voltage of combined discharge is lower than in case of the glow discharge; the stainless steel 12Kh18N10T erosion coefficient is about 1.5 times less in thecase of combined discharge than in the glow one; the thermal desorption diagnostic of wall conditions in the DSM-1 has shown better efficiency with the combined discharge as compared with the glow discharge. Theproposed technology is an original one and has no analogs.Conclusions. The reported research results have shown good prospects for the combined discharge usage for plasma walls conditioning and opportunities for using the combined discharge technology for big fusion machines.
- 28 October 2020
- Published by Cambridge University Press (CUP) in Journal of Plasma Physics
- Vol. 86 (5)
First experiments on ICRF discharge generation by a W7-X-like antenna in the Uragan-2M stellarator
In support of the ICRF experiments planned on the Wendelstein 7-X (W7-X) stellarator, i.e. fast ion generation, wall conditioning, target plasma production and heating, a first experimental study on plasma production has been made in the Uragan-2M (U-2M) stellarator using W7-X-like two-strap antenna. In all the experiments, antenna monopole phasing was used. The W7-X-like antenna operation with launched radiofrequency power of ~100 kW have been performed in helium (p = (4–14) × 10−2 Pa) with the vacuum vessel walls pre-loaded with hydrogen. Production of plasma with a density higher than 1012 cm−3 was observed near the first harmonic of the hydrogen cyclotron frequency. Operation at first hydrogen harmonic is feasible in W7-X future ICRF experiments.
- 28 October 2020
- Published by Cambridge University Press (CUP) in Journal of Plasma Physics
- Vol. 86 (5)
First experiments on ICRF discharge generation by a W7-X-like antenna in the Uragan-2M stellarator
In support of the ICRF experiments planned on the Wendelstein 7-X (W7-X) stellarator, i.e. fast ion generation, wall conditioning, target plasma production and heating, a first experimental study on plasma production has been made in the Uragan-2M (U-2M) stellarator using W7-X-like two-strap antenna. In all the experiments, antenna monopole phasing was used. The W7-X-like antenna operation with launched radiofrequency power of ~100 kW have been performed in helium (p = (4–14) × 10−2 Pa) with the vacuum vessel walls pre-loaded with hydrogen. Production of plasma with a density higher than 1012 cm−3 was observed near the first harmonic of the hydrogen cyclotron frequency. Operation at first hydrogen harmonic is feasible in W7-X future ICRF experiments.
- 1 May 2017
- Published by National Academy of Sciences of Ukraine (Co. LTD Ukrinformnauka) (Publications) in Ukrainian Journal of Physics
- Vol. 62 (4) , 311-317
Alfvén Plasma Heating in Stellarator Uragan-2M
- 1 May 2017
- Published by National Academy of Sciences of Ukraine (Co. LTD Ukrinformnauka) (Publications) in Ukrainian Journal of Physics
- Vol. 62 (4) , 311-317
Alfvén Plasma Heating in Stellarator Uragan-2M
- Open Access
- 1 June 2016
- Published by Walter de Gruyter GmbH in Nukleonika
- Vol. 61 (2) , 91-97
Progress in stellarator research at IPP-Kharkov
A new antenna of ‘crankshaft’ type has been installed in the Uragan-2M device in order to increase the plasma density and heating below the ion cyclotron frequency. Antenna operation is modelled by 1D code, which solves boundary problem for time-harmonic Maxwell’s equations in radially non-uniform plasma cylinder. In recent experiments with this antenna, the SXR, CV, OV and OII emission measurements indicate that the light impurity radiation barrier is overcame at this device. Plasma with a temperature of ~50 eV exists during a short period of a few milliseconds. Then the radiation collapse comes owing to strong influx of impurities to the plasma column. A new magnetic diagnostics has been installed at Uragan-3M. Using it the poloidal magnetic field is measured and the shift of toroidal current in major radius is registered. A miniature pinhole camera array for spatially and temporally resolved measurements of soft X-ray (SXR) plasma emission has been recently installed on the U-3M. Different shapes of the SXR emission profile has been observed in different discharge conditions.
- 1 June 2016
- Published by Walter de Gruyter GmbH in Nukleonika
- Vol. 61 (2) , 91-97
Open AccessProgress in stellarator research at IPP-Kharkov
A new antenna of ‘crankshaft’ type has been installed in the Uragan-2M device in order to increase the plasma density and heating below the ion cyclotron frequency. Antenna operation is modelled by 1D code, which solves boundary problem for time-harmonic Maxwell’s equations in radially non-uniform plasma cylinder. In recent experiments with this antenna, the SXR, CV, OV and OII emission measurements indicate that the light impurity radiation barrier is overcame at this device. Plasma with a temperature of ~50 eV exists during a short period of a few milliseconds. Then the radiation collapse comes owing to strong influx of impurities to the plasma column. A new magnetic diagnostics has been installed at Uragan-3M. Using it the poloidal magnetic field is measured and the shift of toroidal current in major radius is registered. A miniature pinhole camera array for spatially and temporally resolved measurements of soft X-ray (SXR) plasma emission has been recently installed on the U-3M. Different shapes of the SXR emission profile has been observed in different discharge conditions.