AQAaron Quiskamp

Aaron Quiskamp

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Aaron Quiskamp has a total of 69 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    The study of thermal fluctuations in microwave and mechanical resonators

    by Michael T. Hatzon, Eugene N. Ivanov, Aaron Quiskamp, Michael E. Tobar

    We report high-resolution measurements of thermal fluctuations in microwave and mechanical resonators using a dual-channel readout system. The latter comprises a low-noise amplifier, an I/Q-mixer, and a cross-correlator. We discovered that, under certain conditions, the intrinsic fluctuations of the low-noise amplifier, which are common to both channels of the readout system, are averaged out when computing the voltage noise cross-spectrum between the mixer's outputs. The suppression of the amplifier's technical fluctuations significantly improves the contrast of the thermal noise peaks exhibited by the resonators. Thus, for the room-temperature-stabilized 9 GHz sapphire-loaded cavity resonator, we observed more than 16 dB improvement in the thermal noise peak contrast relative to the single-channel measurements. The ability of the dual-channel readout system to discriminate between the broad- and narrow-band fluctuations may benefit the search for dark matter, which relies on the use of cryogenic microwave resonators.

  • Open Access

    Near-quantum-limited axion dark matter search with the ORGAN experiment around 26  μeV

    by Aaron P. Quiskamp, Graeme R. Flower, Steven Samuels, Ben T. McAllister, Paul Altin, Eugene N. Ivanov, Maxim Goryachev, Michael E. Tobar

    The latest result from the ORGAN experiment, an axion haloscope, is presented. This iteration of the experiment operated at millikelvin temperatures using a flux-driven Josephson parametric amplifier for reduced noise, along with various other improvements over previous iterations. Covering the 25.45 − 26.27 μ eV (6.15–6.35 GHz) mass (frequency) range, this near-quantum-limited phase of ORGAN employs a conducting rod resonator and a 7-T solenoidal magnet to place the most sensitive exclusion limits on axion-photon coupling in the range to date, with | g a γ γ | ≳ 2.8 × 10 − 13 at a 95% confidence level.


  • Open Access

    Exclusion of Axionlike-Particle Cogenesis Dark Matter in a Mass Window above 100  μeV

    by Aaron Quiskamp, Ben T. McAllister, Paul Altin, Eugene N. Ivanov, Maxim Goryachev, Michael E. Tobar

    We report the results of Phase 1b of the ORGAN experiment, a microwave cavity haloscope searching for dark matter axions in the 107.42–111.93  μeV mass range. The search excludes axions with two-photon coupling gaγγ≥4×10−12  GeV−1 with 95% confidence interval, setting the best upper bound to date and with the required sensitivity to exclude the axionlike particle cogenesis model for dark matter in this range. This result was achieved using a tunable rectangular cavity, which mitigated several practical issues that become apparent when conducting high-mass axion searches, and was the first such axion search to be conducted with such a cavity. It also represents the most sensitive axion haloscope experiment to date in the ∼100  μeV mass region.


  • Open Access

    Exclusion of ALP Cogenesis Dark Matter in a Mass Window Above 100 $μ$eV

    by Aaron Quiskamp, Ben T. McAllister, Paul Altin, Eugene N. Ivanov, Maxim Goryachev, Michael E. Tobar

    We report the results of Phase 1b of The ORGAN Experiment, a microwave cavity haloscope searching for dark matter axions in the $107.42-111.93~μ$eV mass range. The search excludes axions with two-photon coupling $g_{aγγ}\geq 4\times 10^{-12}\, \textrm{GeV}^{-1}$ with $95\%$ confidence interval, setting the best upper bound to date and with the required sensitivity to exclude the axion-like particle cogenesis model for dark matter in this range. This result was achieved using a tunable rectangular cavity, which mitigated several practical issues that become apparent when conducting high mass axion searches, and was the first such axion search to be conducted with such a cavity. It also represents the most sensitive axion haloscope experiment to date in the $\sim100~μ$eV mass region.

  • Open Access

    Dark matter axion search using a Josephson Traveling wave parametric amplifier

    by C. Bartram, T. Braine, R. Cervantes, N. Crisosto, N. Du, G. Leum, P. Mohapatra, T. Nitta, L. J. Rosenberg, G. Rybka, et al.

    We describe the first implementation of a Josephson Traveling Wave Parametric Amplifier (JTWPA) in an axion dark matter search. The operation of the JTWPA for a period of about two weeks achieved sensitivity to axion-like particle dark matter with axion–photon couplings above 10−13 Ge V−1 over a narrow range of axion masses centered around 19.84 µeV by tuning the resonant frequency of the cavity over the frequency range of 4796.7–4799.5 MHz. The JTWPA was operated in the insert of the axion dark matter experiment as part of an independent receiver chain that was attached to a 0.56-l cavity. The ability of the JTWPA to deliver high gain over a wide (3 GHz) bandwidth has engendered interest from those aiming to perform broadband axion searches, a longstanding goal in this field.


  • Open Access

    Limits on Dark Photons, Scalars, and Axion-Electromagnetodynamics with The ORGAN Experiment

    by Ben T. McAllister, Aaron Quiskamp, Ciaran O'Hare, Paul Altin, Eugene Ivanov, Maxim Goryachev, Michael Tobar

    Axions are a well-motivated dark matter candidate, with a host of experiments around the world searching for direct evidence of their existence. The ORGAN Experiment is a type of axion detector known as an axion haloscope, which takes the form of a cryogenic resonant cavity embedded in a strong magnetic field. ORGAN recently completed Phase 1a, a scan for axions around 65 \textmu eV, and placed the most stringent limits to date on the dark matter axion-photon coupling in this region, $|g_{a\gamma\gamma}|\leq 3\times 10^{-12}$. It has been shown that axion haloscopes such as ORGAN are automatically sensitive to other kinds of dark matter candidates, such as dark photons, scalar field/dilaton dark matter, and exotic axion-electromagnetic couplings motivated by quantum electromagnetodynamics. We compute the exclusion limits placed on these various dark matter candidates by ORGAN 1a, and project sensitivity for some future ORGAN phases. In particular, the dark photon limits are the most sensitive to date in some regions of the parameter space.

  • Open Access

    Comparing Instrument Spectral Sensitivity of Dissimilar Electromagnetic Haloscopes to Axion Dark Matter and High Frequency Gravitational Waves

    by Michael E. Tobar, Catriona A. Thomson, William M. Campbell, Aaron Quiskamp, Jeremy F. Bourhill, Benjamin T. McAllister, Eugene N. Ivanov, Maxim Goryachev

    It is known that haloscopes that search for dark matter axions via the axion-photon anomaly are also sensitive to gravitational radiation through the inverse Gertsenshtein effect. Recently this way of searching for high frequency gravitational waves has gained momentum as it has been shown that the strain sensitivity of such detectors, are of the same order of sensitivity to the axion-photon theta angle. Thus, after calculating the sensitivity of a haloscope to an axion signal, we also have calculated the order of magnitude sensitivity to a gravitational wave signal of the same spectral and temporal form. However, it is unlikely that a gravitational wave and an axion signal will be of the same form, since physically the way the signals are generated are completely different. For gravitational wave detection, the spectral strain sensitivity is in units strain per square root Hz, is the natural way to compare the sensitivity of gravitational wave detectors due to its independence on the gravitational wave signal. In this work, we introduce a systematic way to calculate the spectral sensitivity of an axion haloscope, so instrument comparison may be achieved independent of signal assumptions and only depends on the axion to signal transduction sensitivity and noise in the instrument. Thus, the calculation of the spectral sensitivity not only allows the comparison of dissimilar axion detectors independent of signal, but also allows us to compare the order of magnitude gravitational wave sensitivity in terms of spectral strain sensitivity, allowing comparisons to standard gravitational wave detectors based on optical interferometers and resonant-mass technology.


  • Open Access

    Direct search for dark matter axions excluding ALP cogenesis in the 63- to 67-μeV range with the ORGAN experiment

    by Aaron Quiskamp, Ben T. McAllister, Paul Altin, Eugene N. Ivanov, Maxim Goryachev, Michael E. Tobar

    The standard model axion seesaw Higgs portal inflation (SMASH) model is a well-motivated, self-contained description of particle physics that predicts axion dark matter particles to exist within the mass range of 50 to 200 micro–electron volts. Scanning these masses requires an axion haloscope to operate under a constant magnetic field between 12 and 48 gigahertz. The ORGAN (Oscillating Resonant Group AxioN) experiment (in Perth, Australia) is a microwave cavity axion haloscope that aims to search the majority of the mass range predicted by the SMASH model. Our initial phase 1a scan sets an upper limit on the coupling of axions to two photons of ∣ g aγγ ∣ ≤ 3 × 10 −12 per giga–electron volts over the mass range of 63.2 to 67.1 micro–electron volts with 95% confidence interval. This highly sensitive result is sufficient to exclude the well-motivated axion-like particle cogenesis model for dark matter in the searched region.


  • Open Access

    Dielectric-Boosted Sensitivity to Cylindrical Azimuthally Varying Transverse-Magnetic Resonant Modes in an Axion Haloscope

    by Aaron P. Quiskamp, Ben T. McAllister, Gray Rybka, Michael E. Tobar

    Axions are a popular dark matter candidate which are often searched for in experiments known as ``haloscopes" which exploit a putative axion-photon coupling. These experiments typically rely on Transverse Magnetic (TM) modes in resonant cavities to capture and detect photons generated via axion conversion. We present a study of a resonant cavity design for application in haloscope searches, of particular use in the push to higher mass axion searches (above $\sim$60$\,\mu$eV). In particular, we take advantage of azimuthally varying TM$_{m10}$ modes which, whilst typically insensitive to axions due to field non-uniformity, can be made axion-sensitive (and frequency tunable) through strategic placement of dielectric wedges, becoming a type of resonator known as a Dielectric Boosted Axion Sensitivity (DBAS) resonator. Results from finite-element modelling are presented, and compared with a simple proof-of-concept experiment. The results show a significant increase in axion sensitivity for these DBAS resonators over their empty cavity counterparts, and high potential for application in high mass axion searches when benchmarked against simpler, more traditional designs relying on fundamental TM modes.

  • Dielectric-Boosted Sensitivity to Cylindrical Azimuthally Varying Transverse-Magnetic Resonant Modes in an Axion Haloscope

    by Aaron P. Quiskamp, Ben T. McAllister, Gray Rybka, Michael E. Tobar

    Axions are a popular dark-matter candidate that are often searched for in experiments known as “haloscopes,” which exploit a putative axion-photon coupling. These experiments typically rely on transverse-magnetic (TM) modes in resonant cavities to capture and detect photons generated via axion conversion. We present a study of a resonant-cavity design for application in haloscope searches, of particular use in the push to higher-mass axion searches (above approximately 60μeV). In particular, we take advantage of azimuthally varying TMm10 modes that, while typically insensitive to axions due to field nonuniformity, can be made axion sensitive (and frequency tunable) through the strategic placement of dielectric wedges, becoming a type of resonator known as a dielectric-boosted axion-sensitivity (DBAS) resonator. Results from finite-element modeling are presented and compared with a simple proof-of-concept experiment. The results show a significant increase in axion sensitivity for these DBAS resonators over their empty-cavity counterparts and high potential for application in high-mass axion searches when benchmarked against simpler more traditional designs that rely on fundamental TM modes.