Chaimongkon Peampring
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Chaimongkon Peampring has a total of 25 co-authors. Here are the top co-authors by number of shared publications:
Kanyakorn Charoenphol
Department of Prosthetic Dentistry, Prince of Songkla University, Hat Yai, Songkhla, Thailand
2 shared publications- Putsadeeporn Thammajaruk
Department of Prosthetic Dentistry, Faculty of Dentistry, Prince of Songkla University, Songkhla 90110, Thailand
2 shared publications - Santiphab Kengtanyakich
Department of Restorative Dentistry, Faculty of Dentistry, Naresuan University, Phitsanulok 65000, Thailand
2 shared publications - Suchada Kongkiatkamon
Bangkok Hospital Dental Center, Bangkok Hospital, Bangkok 10310, Thailand
2 shared publications Chanya Chuenarrom
Department of Prosthetic Dentistry, Faculty of Dentistry, Prince of Songkla University, Songkhla 90110, Thailand
1 shared publicationChenwei Han
UPCERA Collaborative Research Center, Liaoning Upcera Co., Ltd., Shenyang, China
1 shared publication
Latest Publications
- Open Access
- 1 October 2026
- Published by Wolters Kluwer Health in The Journal of Indian Prosthodontic Society
- Vol. 26 (4) , 323-330
Digital versus conventional complete dentures: A randomized controlled pilot study of short-term patient satisfaction and quality of life within a mobile dental service setting
Aim: Conventional complete denture (CD) fabrication requires multiple appointments, posing barriers for remote elderly patients.This study compared oral health-related quality of life (OHRQoL) and patient satisfaction between digitally fabricated dentures (DD) and conventional methods within the Royal Mobile Dental Services in Thailand. Settings and Designs: In this prospective randomized trial, 30 edentulous participants (aged 50–80 years) were allocated to CD ( n = 15) or DD ( n = 15) groups; 25 participants (CD: n = 15, DD: n = 10) completed the 1.5-month evaluation. Materials and Methods: The CD protocol used a four-visit, heat-polymerized workflow. The DD protocol used a three-visit workflow with mucostatic intraoral scanning and three-dimensional (3D) printing dentures. Participants and outcome assessors were blinded. Statistical Analysis Used: Outcomes were assessed after the first meal, at 24 h, and at 1.5 months using a Visual Analog Scale (VAS) for satisfaction and the Oral Health Impact Profile-14 for OHRQoL. Data were analyzed using Mann–Whitney U -tests. Results: Overall VAS satisfaction showed no significant intergroup differences ( P > 0.05). At 24 h, the DD group reported significantly higher negative impacts ( P < 0.05) on phonetics, taste perception, and food avoidance. By 1.5 months, most OHRQoL dimensions in the DD group normalized to match the CD group, but phonetic difficulties remained significantly higher ( P < 0.05). Conclusion: 3D-printed dentures offer satisfaction comparable to conventional methods while reducing clinical visits. Early functional limitations resolve rapidly, but persistent phonetic issues suggest that standardized computer-aided design protocols may benefit from patient-specific customization to optimize speech outcomes in mobile dental settings.
- 1 October 2026
- Published by Wolters Kluwer Health in The Journal of Indian Prosthodontic Society
- Vol. 26 (4) , 323-330
Open AccessDigital versus conventional complete dentures: A randomized controlled pilot study of short-term patient satisfaction and quality of life within a mobile dental service setting
Aim: Conventional complete denture (CD) fabrication requires multiple appointments, posing barriers for remote elderly patients.This study compared oral health-related quality of life (OHRQoL) and patient satisfaction between digitally fabricated dentures (DD) and conventional methods within the Royal Mobile Dental Services in Thailand. Settings and Designs: In this prospective randomized trial, 30 edentulous participants (aged 50–80 years) were allocated to CD ( n = 15) or DD ( n = 15) groups; 25 participants (CD: n = 15, DD: n = 10) completed the 1.5-month evaluation. Materials and Methods: The CD protocol used a four-visit, heat-polymerized workflow. The DD protocol used a three-visit workflow with mucostatic intraoral scanning and three-dimensional (3D) printing dentures. Participants and outcome assessors were blinded. Statistical Analysis Used: Outcomes were assessed after the first meal, at 24 h, and at 1.5 months using a Visual Analog Scale (VAS) for satisfaction and the Oral Health Impact Profile-14 for OHRQoL. Data were analyzed using Mann–Whitney U -tests. Results: Overall VAS satisfaction showed no significant intergroup differences ( P > 0.05). At 24 h, the DD group reported significantly higher negative impacts ( P < 0.05) on phonetics, taste perception, and food avoidance. By 1.5 months, most OHRQoL dimensions in the DD group normalized to match the CD group, but phonetic difficulties remained significantly higher ( P < 0.05). Conclusion: 3D-printed dentures offer satisfaction comparable to conventional methods while reducing clinical visits. Early functional limitations resolve rapidly, but persistent phonetic issues suggest that standardized computer-aided design protocols may benefit from patient-specific customization to optimize speech outcomes in mobile dental settings.
- 10 June 2026
- Published by Elsevier in Dental Materials
- Vol. 42 (11) , 2119-2125
Comparative wear behavior of lithium disilicate CAD/CAM ceramics under simulated mastication
- 10 June 2026
- Published by Elsevier in Dental Materials
- Vol. 42 (11) , 2119-2125
Comparative wear behavior of lithium disilicate CAD/CAM ceramics under simulated mastication
- Open Access
- 1 January 2026
- Published by Wiley in International Journal of Dentistry
- Vol. 2026 (1) , 2778184
Evaluation of the Trueness and Precision of a Simplified Method for Transferring the Relationship of the Maxillary Plane and Transverse Hinge Axis to Virtual Articulators
Background: The digital transfer of data for establishing the maxillary occlusal plane and condylar path aims for high precision, facilitating accurate use of virtual articulators and aiding in digital prosthetic fabrication. Objective: This study evaluates the accuracy of transferring maxillary scans to a virtual articulator using a novel customized transfer tool compared to a conventional facebow system. Methods: Three types of master models, bilateral balanced, monoplane, and lingualized occlusion, were prepared and duplicated. Landmarks on the maxillary and mandibular models were identified, and interlandmark distances served as controls. The models were scanned intraorally, and virtual bite alignment was performed using a best‐fit algorithm. A manual facebow transfer defined the occlusal and condylar relationships on a mechanical articulator, which was then transferred to a virtual articulator via the customized transfer tool and computer‐aided design (CAD) software. Transfer accuracy was assessed by comparing interlandmark distances between mechanical and virtual setups using statistical tests (Shapiro–Wilk, Levene’s, and t ‐tests) at α = 0.05. Reliability was evaluated with the intraclass correlation coefficient (ICC). Results: No significant differences were found between the mechanical and virtual interlandmark distances across all models ( p > 0.05). Differences ranged from −0.08 to 0.11 mm, within clinically acceptable limits. ICC values exceeded 0.80, indicating high reliability of the transfer method. Conclusions: The customized transfer tool accurately transferred maxillary occlusal plane and condylar path relationships to the virtual articulator, with no significant discrepancies observed.
- 1 January 2026
- Published by Wiley in International Journal of Dentistry
- Vol. 2026 (1) , 2778184
Open AccessEvaluation of the Trueness and Precision of a Simplified Method for Transferring the Relationship of the Maxillary Plane and Transverse Hinge Axis to Virtual Articulators
Background: The digital transfer of data for establishing the maxillary occlusal plane and condylar path aims for high precision, facilitating accurate use of virtual articulators and aiding in digital prosthetic fabrication. Objective: This study evaluates the accuracy of transferring maxillary scans to a virtual articulator using a novel customized transfer tool compared to a conventional facebow system. Methods: Three types of master models, bilateral balanced, monoplane, and lingualized occlusion, were prepared and duplicated. Landmarks on the maxillary and mandibular models were identified, and interlandmark distances served as controls. The models were scanned intraorally, and virtual bite alignment was performed using a best‐fit algorithm. A manual facebow transfer defined the occlusal and condylar relationships on a mechanical articulator, which was then transferred to a virtual articulator via the customized transfer tool and computer‐aided design (CAD) software. Transfer accuracy was assessed by comparing interlandmark distances between mechanical and virtual setups using statistical tests (Shapiro–Wilk, Levene’s, and t ‐tests) at α = 0.05. Reliability was evaluated with the intraclass correlation coefficient (ICC). Results: No significant differences were found between the mechanical and virtual interlandmark distances across all models ( p > 0.05). Differences ranged from −0.08 to 0.11 mm, within clinically acceptable limits. ICC values exceeded 0.80, indicating high reliability of the transfer method. Conclusions: The customized transfer tool accurately transferred maxillary occlusal plane and condylar path relationships to the virtual articulator, with no significant discrepancies observed.
- Open Access
- 1 January 2026
- Published by XMLink in The Journal of Advanced Prosthodontics
- Vol. 18 (1) , 25-35
Wear of 3D-printed resin denture teeth under self-antagonist conditions after chewing simulation
Rungsitsathien S, et al. J Adv Prosthodont. 2026 Feb;18(1):25-35. https://doi.org/10.4047/jap.2026.18.1.25
- 1 January 2026
- Published by XMLink in The Journal of Advanced Prosthodontics
- Vol. 18 (1) , 25-35
Open AccessWear of 3D-printed resin denture teeth under self-antagonist conditions after chewing simulation
Rungsitsathien S, et al. J Adv Prosthodont. 2026 Feb;18(1):25-35. https://doi.org/10.4047/jap.2026.18.1.25
- 15 March 2025
- Published by Springer Nature in Clinical Oral Investigations
- Vol. 29 (4) , 1-11
Surface modification of polyether ether ketone (PEEK) via sulfonation and hydroxyapatite coating: impact on shear bond strength with resin composite
Purpose This study evaluates the effects of various polyetheretherketone (PEEK) surface treatments on its shear bond strength (SBS) with flowable resin composite. Methods A total of 120 PEEK disks were categorized into five groups: untreated PEEK (control), sandblasted with 50 μm alumina (Sa PEEK), etched with 98% sulfuric acid for 1 min (S PEEK), hydroxyapatite-coated sulfonated PEEK (HA PEEK), and phosphoric acid-etched HA-coated PEEK (HAP PEEK). Each group was subdivided into two groups (n = 12): Scotchbond Universal Plus (Scb) and Single Bond Universal (Sib) adhesive application and bond with flowable resin composite. SBS was evaluated after thermocycling for 5000 cycles and the results were analyzed using two-way and one-way ANOVA, followed by Tukey’s HSD (α = 0.05). Failure mode was analyzed using light and scanning electron microscope. Surface roughness and contact angle analysis of each surface treatment were also done. Results HA PEEK exhibited the highest SBS in both Scb and Sib, while untreated PEEK showed the lowest. The effect of bonding agent can be seen only in S PEEK group where Sib demonstrated significantly higher SBS (P < 0.05) than Scb. Cohesive and mixed failures were observed in HA PEEK and HAP PEEK groups and others showed mostly adhesive failure. The wettability of PEEK increased after surface treatment except for Sa PEEK. Conclusions HA PEEK consistently achieved the highest SBS, indicating that combining sulfonation with HA coating is an effective strategy to enhance bonding between PEEK and flowable resin composite.
- 15 March 2025
- Published by Springer Nature in Clinical Oral Investigations
- Vol. 29 (4) , 1-11
Surface modification of polyether ether ketone (PEEK) via sulfonation and hydroxyapatite coating: impact on shear bond strength with resin composite
Purpose This study evaluates the effects of various polyetheretherketone (PEEK) surface treatments on its shear bond strength (SBS) with flowable resin composite. Methods A total of 120 PEEK disks were categorized into five groups: untreated PEEK (control), sandblasted with 50 μm alumina (Sa PEEK), etched with 98% sulfuric acid for 1 min (S PEEK), hydroxyapatite-coated sulfonated PEEK (HA PEEK), and phosphoric acid-etched HA-coated PEEK (HAP PEEK). Each group was subdivided into two groups (n = 12): Scotchbond Universal Plus (Scb) and Single Bond Universal (Sib) adhesive application and bond with flowable resin composite. SBS was evaluated after thermocycling for 5000 cycles and the results were analyzed using two-way and one-way ANOVA, followed by Tukey’s HSD (α = 0.05). Failure mode was analyzed using light and scanning electron microscope. Surface roughness and contact angle analysis of each surface treatment were also done. Results HA PEEK exhibited the highest SBS in both Scb and Sib, while untreated PEEK showed the lowest. The effect of bonding agent can be seen only in S PEEK group where Sib demonstrated significantly higher SBS (P < 0.05) than Scb. Cohesive and mixed failures were observed in HA PEEK and HAP PEEK groups and others showed mostly adhesive failure. The wettability of PEEK increased after surface treatment except for Sa PEEK. Conclusions HA PEEK consistently achieved the highest SBS, indicating that combining sulfonation with HA coating is an effective strategy to enhance bonding between PEEK and flowable resin composite.
- Open Access
- 27 January 2025
- Published by Georg Thieme Verlag KG in European Journal of General Dentistry
- Vol. 14 (03) , 302-307
Accuracy and Reliability of Intraoral Scanners for Tooth Shade Determination in Comparisons with Intraoral Spectrophotometer: In Vitro Study
This study aimed to compare the accuracy and repeatability of shade determination using an intraoral spectrophotometer (SP) and two intraoral scanners, hypothesizing no significant differences in performance.A computer-aided design/computer-aided manufacturing-designed right upper central incisor was manufactured in multiple shades using feldspathic ceramic. Shade determination was performed using the CEREC Primescan (CP), Trios V scanners, and an intraoral SP, with multiple scans taken for each.Measurement accuracy was evaluated using the Cochran Q test and pairwise comparisons with Bonferroni's correction. Reliability was assessed through Cronbach's α, with a significance level set at 0.05 for all tests.The SP achieved 84% accuracy, while the CP and 3Shape Trios V (T5) recorded 66 and 71%, respectively. None of the instruments reached 100% accuracy, with the SP displaying an accuracy range of 80 to 90%, and both scanners achieving between 60 and 80%. Statistically significant differences indicated that the SP outperformed the scanners (p < 0.05). False shade readings showed shades 3M2 and 4M2 as having the highest erroneous results. Reliability scores ranged from 92% for the scanners to 94% for the SP, with a Cronbach's α coefficient of 0.839, indicating high reliability.Intraoral SP displayed superior accuracy over the intraoral scanners, while their reliability in shade assessment was comparable. Thus, dental SPs are preferred for precise shade matching, suggesting potential reliability issues with intraoral scanners for consistent dental shade assessment.
- 27 January 2025
- Published by Georg Thieme Verlag KG in European Journal of General Dentistry
- Vol. 14 (03) , 302-307
Open AccessAccuracy and Reliability of Intraoral Scanners for Tooth Shade Determination in Comparisons with Intraoral Spectrophotometer: In Vitro Study
This study aimed to compare the accuracy and repeatability of shade determination using an intraoral spectrophotometer (SP) and two intraoral scanners, hypothesizing no significant differences in performance.A computer-aided design/computer-aided manufacturing-designed right upper central incisor was manufactured in multiple shades using feldspathic ceramic. Shade determination was performed using the CEREC Primescan (CP), Trios V scanners, and an intraoral SP, with multiple scans taken for each.Measurement accuracy was evaluated using the Cochran Q test and pairwise comparisons with Bonferroni's correction. Reliability was assessed through Cronbach's α, with a significance level set at 0.05 for all tests.The SP achieved 84% accuracy, while the CP and 3Shape Trios V (T5) recorded 66 and 71%, respectively. None of the instruments reached 100% accuracy, with the SP displaying an accuracy range of 80 to 90%, and both scanners achieving between 60 and 80%. Statistically significant differences indicated that the SP outperformed the scanners (p < 0.05). False shade readings showed shades 3M2 and 4M2 as having the highest erroneous results. Reliability scores ranged from 92% for the scanners to 94% for the SP, with a Cronbach's α coefficient of 0.839, indicating high reliability.Intraoral SP displayed superior accuracy over the intraoral scanners, while their reliability in shade assessment was comparable. Thus, dental SPs are preferred for precise shade matching, suggesting potential reliability issues with intraoral scanners for consistent dental shade assessment.
- Open Access
- 1 January 2025
- Published by XMLink in The Journal of Advanced Prosthodontics
- Vol. 17 (3) , 146-157
Fracture strength and failure mode of implant-supported provisional resin composite crowns on hydroxyapatite-coated sulfonated PEEK abutments following thermomechanical loading
Htay TP, et al. J Adv Prosthodont. 2025 Jun;17(3):146-157. https://doi.org/10.4047/jap.2025.17.3.146
- 1 January 2025
- Published by XMLink in The Journal of Advanced Prosthodontics
- Vol. 17 (3) , 146-157
Open AccessFracture strength and failure mode of implant-supported provisional resin composite crowns on hydroxyapatite-coated sulfonated PEEK abutments following thermomechanical loading
Htay TP, et al. J Adv Prosthodont. 2025 Jun;17(3):146-157. https://doi.org/10.4047/jap.2025.17.3.146
- Open Access
- 13 December 2022
- Published by Georg Thieme Verlag KG in European Journal of Dentistry
- Vol. 17 (03) , 889-894
Fit Accuracy of Complete Denture Base Fabricated by CAD/CAM Milling and 3D-Printing Methods
Objective Digital complete denture fabrication can be accomplished by either milling or three-dimensional (3D)-printing approach in which minimal distortion during processing contributes to effective denture base adaption, which leads to good denture retention. The purpose of this study was to compare the fit accuracy of milled and 3D-printed complete denture bases. Materials and Methods The reference edentulous maxillary arch model was scanned to generate virtual denture bases using computer-aided manufacturing software that exports as standard tessellation language files. Denture bases were constructed using a milling and 3D-printing technique using digital light processing method (n = 10). Intaglio surfaces of denture bases were scanned and superimposed on the reference model. The fit accuracy was quantified as root mean square error and evaluated statistically using independent t-test comparisons with a significance level of 0.05. Results Milled denture bases were significantly more accurate in adaptation than 3D-printed dentures in the overall intaglio area and primary bearing area of denture bases. 3D-printed denture bases demonstrated significantly greater accuracy in adaptation than milled denture bases in the peripheral/posterior palatal seal area. Conclusion Milled denture bases fit better in the overall and primary stress-bearing areas than 3D-printed dentures, while 3D-printed dentures appeared more accurate in the peripheral seal area, which had a minor undercut that is not suitable for using milling technology.
- 13 December 2022
- Published by Georg Thieme Verlag KG in European Journal of Dentistry
- Vol. 17 (03) , 889-894
Open AccessFit Accuracy of Complete Denture Base Fabricated by CAD/CAM Milling and 3D-Printing Methods
Objective Digital complete denture fabrication can be accomplished by either milling or three-dimensional (3D)-printing approach in which minimal distortion during processing contributes to effective denture base adaption, which leads to good denture retention. The purpose of this study was to compare the fit accuracy of milled and 3D-printed complete denture bases. Materials and Methods The reference edentulous maxillary arch model was scanned to generate virtual denture bases using computer-aided manufacturing software that exports as standard tessellation language files. Denture bases were constructed using a milling and 3D-printing technique using digital light processing method (n = 10). Intaglio surfaces of denture bases were scanned and superimposed on the reference model. The fit accuracy was quantified as root mean square error and evaluated statistically using independent t-test comparisons with a significance level of 0.05. Results Milled denture bases were significantly more accurate in adaptation than 3D-printed dentures in the overall intaglio area and primary bearing area of denture bases. 3D-printed denture bases demonstrated significantly greater accuracy in adaptation than milled denture bases in the peripheral/posterior palatal seal area. Conclusion Milled denture bases fit better in the overall and primary stress-bearing areas than 3D-printed dentures, while 3D-printed dentures appeared more accurate in the peripheral seal area, which had a minor undercut that is not suitable for using milling technology.
- Open Access
- 8 December 2022
- Published by MDPI AG in Journal of Functional Biomaterials
- Vol. 13 (4) , 281
Comparison of Regular and Speed Sintering on Low-Temperature Degradation and Fatigue Resistance of Translucent Zirconia Crowns for Implants: An In Vitro Study
Background: Although there are a few studies which compare fast and slow sintering in normal zirconia crowns, it is essential to compare the cracks and load-bearing capacity in zirconia screw-retained implant crowns between regular and speed sintering protocols. This research aimed to compare the surface structure, cracks, and load-bearing capacity in zirconia screw-retained implant crowns between regular sintering (RS) and speed sintering (SS) protocol with and without cyclic loading (fatigue). Methods: A total of 60 screw-retained crowns were fabricated from zirconia (Katana STML Block) by the CAD/CAM system. Then, 30 crowns were subjected to the RS protocol and 30 crowns were subjected to the SS protocol. Cyclic loading was done in half zirconia crowns (15 crowns in each group) using a chewing simulator CS-4.8/CS-4.4 at room temperature. The loading force was applied on the middle of the crowns by a metal stylus underwater at room temperature with a chewing simulator at an axial 50 N load for 240,000 cycles and lateral movement at 2 mm. Scanning electron microscopy was done to study the surface of the crowns and the cracks in the crowns of the regular and speed sintering protocols, with and without fatigue. Results: For the speed sintering group, the surface looks more uniform, and the crack lines are present at a short distance compared to regular sintering. The sintering protocol with a larger Weibull module and durability increases the reliability. It showed that the Speed group showed the maximum fracture load, followed by the regular, speed fatigue, and regular fatigue groups. The fracture load in various groups showed significant differences. Conclusions: It was found that the speed group showed the maximum fracture load followed by the regular, speed fatigue, and regular fatigue. The crack lines ran from occlusal to bottoms (gingiva) and the arrest lines were perpendicular to the crack propagations.
- 8 December 2022
- Published by MDPI AG in Journal of Functional Biomaterials
- Vol. 13 (4) , 281
Open AccessComparison of Regular and Speed Sintering on Low-Temperature Degradation and Fatigue Resistance of Translucent Zirconia Crowns for Implants: An In Vitro Study
Background: Although there are a few studies which compare fast and slow sintering in normal zirconia crowns, it is essential to compare the cracks and load-bearing capacity in zirconia screw-retained implant crowns between regular and speed sintering protocols. This research aimed to compare the surface structure, cracks, and load-bearing capacity in zirconia screw-retained implant crowns between regular sintering (RS) and speed sintering (SS) protocol with and without cyclic loading (fatigue). Methods: A total of 60 screw-retained crowns were fabricated from zirconia (Katana STML Block) by the CAD/CAM system. Then, 30 crowns were subjected to the RS protocol and 30 crowns were subjected to the SS protocol. Cyclic loading was done in half zirconia crowns (15 crowns in each group) using a chewing simulator CS-4.8/CS-4.4 at room temperature. The loading force was applied on the middle of the crowns by a metal stylus underwater at room temperature with a chewing simulator at an axial 50 N load for 240,000 cycles and lateral movement at 2 mm. Scanning electron microscopy was done to study the surface of the crowns and the cracks in the crowns of the regular and speed sintering protocols, with and without fatigue. Results: For the speed sintering group, the surface looks more uniform, and the crack lines are present at a short distance compared to regular sintering. The sintering protocol with a larger Weibull module and durability increases the reliability. It showed that the Speed group showed the maximum fracture load, followed by the regular, speed fatigue, and regular fatigue groups. The fracture load in various groups showed significant differences. Conclusions: It was found that the speed group showed the maximum fracture load followed by the regular, speed fatigue, and regular fatigue. The crack lines ran from occlusal to bottoms (gingiva) and the arrest lines were perpendicular to the crack propagations.