Lijuan Sun
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Lijuan Sun has a total of 15 co-authors. Here are the top co-authors by number of shared publications:
- Yewang Su
State Key Laboratory of Nonlinear Mechanics Institute of Mechanics Chinese Academy of Sciences Beijing China
2 shared publications - Chong Liu
State Key Laboratory of High-temperature Gas Dynamics, Institute of Mechanics, Chinese Academy of Sciences, Beijing 100190, China
1 shared publication - Di Zheng
School of Civil and Resources Engineering, University of Science and Technology Beijing, Beijing 100083, China
1 shared publication Guodong Liu
Chinese Academy of Sciences State Key Laboratory of Nonlinear Mechanics, Institute of Mechanics Beijing 100190 , China
1 shared publication- Guodong Liu
State Key Laboratory of Nonlinear Mechanics, Institute of Mechanics, Chinese Academy of Sciences, Beijing 100190, China
1 shared publication Hanhuan Wang
AECC Shenyang Liming Aero ENGINE Co., Ltd. , Shenyang , 110046 , China
1 shared publication
Latest Publications
- Open Access
- 1 January 2024
- Published by Walter de Gruyter GmbH in Science and Engineering of Composite Materials
- Vol. 31 (1)
Research on damage evolution mechanisms under compressive and tensile tests of plain weave SiC f /SiC composites using in situ X-ray CT
To investigate the damage evolution and failure mechanisms of fiber-reinforced composite materials under complex conditions, this study conducted in situ X-ray computed tomography (CT) compression and tensile tests on plain weave two-dimensional woven SiC/SiC composite materials. The obtained CT in situ image data captured the behavior of materials during loading and after failure. Using the image reconstruction of CT data, the actual microstructure and damage evolution of the material under six consecutive loading levels were accurately revealed. Three-dimensional visualization models of the composite material were established using image processing software to analyze the damage evolution under compression and tension, and the failure mechanisms were compared. The results showed that the compression and tension failure mechanisms of SiC/SiC composite materials were similar, with the transverse cracking of the matrix being the first mode of damage, followed by delamination between layers and longitudinal matrix cracking of fiber bundles. Specifically, in terms of compression failure, the strength of the fiber bundle itself has a greater influence, and fiber fracture is the main cause of ultimate material failure. On the other hand, the primary cause of tensile failure is the presence of porosity defects generated during material fabrication. Consequently, the tensile material fails earlier and can withstand lower loads.
- 1 January 2024
- Published by Walter de Gruyter GmbH in Science and Engineering of Composite Materials
- Vol. 31 (1)
Open AccessResearch on damage evolution mechanisms under compressive and tensile tests of plain weave SiC f /SiC composites using in situ X-ray CT
To investigate the damage evolution and failure mechanisms of fiber-reinforced composite materials under complex conditions, this study conducted in situ X-ray computed tomography (CT) compression and tensile tests on plain weave two-dimensional woven SiC/SiC composite materials. The obtained CT in situ image data captured the behavior of materials during loading and after failure. Using the image reconstruction of CT data, the actual microstructure and damage evolution of the material under six consecutive loading levels were accurately revealed. Three-dimensional visualization models of the composite material were established using image processing software to analyze the damage evolution under compression and tension, and the failure mechanisms were compared. The results showed that the compression and tension failure mechanisms of SiC/SiC composite materials were similar, with the transverse cracking of the matrix being the first mode of damage, followed by delamination between layers and longitudinal matrix cracking of fiber bundles. Specifically, in terms of compression failure, the strength of the fiber bundle itself has a greater influence, and fiber fracture is the main cause of ultimate material failure. On the other hand, the primary cause of tensile failure is the presence of porosity defects generated during material fabrication. Consequently, the tensile material fails earlier and can withstand lower loads.
- 16 March 2023
- Published by Wiley in Journal of Applied Mechanics
- Vol. 90 (7) , 1-29
One-Step Patterned Contact-Resistance-Free Stretchable Strain Sensors With High Linearity and Repeatability for Body-Motion Detection
Most of the resistive-type stretchable strain sensors exhibit large sensing ranges and high sensitivity but suboptimal repeatability and linearity because of the contact-resistance mechanism. To achieve high repeatability and linearity, several sensors with contact-resistance-free structures are proposed. However, due to the different geometric layouts of the conductive materials and the insulating substrates, the patterning of these sensors requires multiple processes including photolithography and etching, which may cause high costs and are not suitable for consumer wearable applications. Here, we report a design for stretchable strain sensors based on a one-step patterned contact-resistance-free structure, i.e., the independent-sensing-and-stretchable-function structure (ISSFS). The stretchability mainly comes from the overall large deformation of the wide curved segments (the stretchable parts), while the resistance variation is mainly attributed to the tensile strain of the narrow straight segments (the sensing parts). High linearity (R2 = 0.999) and repeatability (repeatability error = 1.44%) are achieved because neither unstable contact resistance nor nonlinear constitutive and geometric behaviors occur during the sensing process. The conductive materials and the insulating substrates do not need to have different geometric layouts; thus, they can be patterned by only one-step laser cutting. The proposed sensors show great potential in body-motion detection for wearable devices.
- 16 March 2023
- Published by Wiley in Journal of Applied Mechanics
- Vol. 90 (7) , 1-29
One-Step Patterned Contact-Resistance-Free Stretchable Strain Sensors With High Linearity and Repeatability for Body-Motion Detection
Most of the resistive-type stretchable strain sensors exhibit large sensing ranges and high sensitivity but suboptimal repeatability and linearity because of the contact-resistance mechanism. To achieve high repeatability and linearity, several sensors with contact-resistance-free structures are proposed. However, due to the different geometric layouts of the conductive materials and the insulating substrates, the patterning of these sensors requires multiple processes including photolithography and etching, which may cause high costs and are not suitable for consumer wearable applications. Here, we report a design for stretchable strain sensors based on a one-step patterned contact-resistance-free structure, i.e., the independent-sensing-and-stretchable-function structure (ISSFS). The stretchability mainly comes from the overall large deformation of the wide curved segments (the stretchable parts), while the resistance variation is mainly attributed to the tensile strain of the narrow straight segments (the sensing parts). High linearity (R2 = 0.999) and repeatability (repeatability error = 1.44%) are achieved because neither unstable contact resistance nor nonlinear constitutive and geometric behaviors occur during the sensing process. The conductive materials and the insulating substrates do not need to have different geometric layouts; thus, they can be patterned by only one-step laser cutting. The proposed sensors show great potential in body-motion detection for wearable devices.
- Open Access
Investigation on Dynamical Mechanics, Energy Dissipation, and Microstructural Characteristics of Cemented Tailings Backfill under SHPB Tests
As mining depth increases, the backfill mining method is more and more widely used in underground mines. The dynamic load generated by the blasting can affect the stability of the cemented tailings backfill (CTB). The CTB samples were prepared to conduct a test of the split Hopkinson pressure bar (SHPB) to investigate the dynamic disturbance of CTB. The present paper discusses dynamical mechanics, energy dissipation, and microstructure analysis of CTB. Micro-computer tomography (micro-CT) scanning of CTB samples after the SHPB test was performed to analyze the evolution of internal cracks. The experimental results showed that when the average strain rate (ASR) increased from 30 to 98 s−1, the dynamic uniaxial compression strength (DUCS) of the CTB showed a trend of first increasing and decreasing with the increase in ASR. The dynamic stress–strain pre-peak curve of CTB directly enters the linear elastic stage. As ASR increases, the absorbed energy of the CTB shows a trend of first increasing and then decreasing. Moreover, according to the micro-CT scanning results, the crack area of CTB accounts for about 16% of the sample near the incident bar and about 1% near the transmitted bar. The crack area ratio is exponentially related to the specimen height. These findings can provide reasonable dynamical CTB strength data selection for underground pillar mining.
Open AccessInvestigation on Dynamical Mechanics, Energy Dissipation, and Microstructural Characteristics of Cemented Tailings Backfill under SHPB Tests
As mining depth increases, the backfill mining method is more and more widely used in underground mines. The dynamic load generated by the blasting can affect the stability of the cemented tailings backfill (CTB). The CTB samples were prepared to conduct a test of the split Hopkinson pressure bar (SHPB) to investigate the dynamic disturbance of CTB. The present paper discusses dynamical mechanics, energy dissipation, and microstructure analysis of CTB. Micro-computer tomography (micro-CT) scanning of CTB samples after the SHPB test was performed to analyze the evolution of internal cracks. The experimental results showed that when the average strain rate (ASR) increased from 30 to 98 s−1, the dynamic uniaxial compression strength (DUCS) of the CTB showed a trend of first increasing and decreasing with the increase in ASR. The dynamic stress–strain pre-peak curve of CTB directly enters the linear elastic stage. As ASR increases, the absorbed energy of the CTB shows a trend of first increasing and then decreasing. Moreover, according to the micro-CT scanning results, the crack area of CTB accounts for about 16% of the sample near the incident bar and about 1% near the transmitted bar. The crack area ratio is exponentially related to the specimen height. These findings can provide reasonable dynamical CTB strength data selection for underground pillar mining.
- 29 May 2020
- Published by Wiley in Journal of Applied Mechanics
- Vol. 87 (8) , 1-17
Scaling Effects in the Mechanical System of the Flexible Epidermal Electronics and the Human Skin
The “island-bridge” mesh structure is widely adopted for flexible epidermal electronics to simultaneously achieve the electronic functions and mechanical flexibility. Mechanical intuition tells that the small size of the “island” is beneficial to the flexibility of the structure and the adaptability to complex geometric targets. Here, a plane-strain model and an axisymmetric model are established for square “island” and cycle “island,” respectively, to analyze the mechanical system consisting of the flexible epidermal electronics and the human skin. It is found that the pressure between the “island” and the human skin is positive at the inner region and reaches a peak value at the center, while is negative at the outer region and approaches infinite at the boundary of the contact region. With the increase in the size a/R0, the amplitude of the pressure significantly increases, as well as the singular degree of the pressure at the boundary. The reduction of the “island” size is beneficial for the optimization of the “comfort level” of the flexible epidermal electronics. The models degenerate into the famous Johnson-Kendall-Roberts (JKR) model for the limit case with extremely hard and thick “island.”
- 29 May 2020
- Published by Wiley in Journal of Applied Mechanics
- Vol. 87 (8) , 1-17
Scaling Effects in the Mechanical System of the Flexible Epidermal Electronics and the Human Skin
The “island-bridge” mesh structure is widely adopted for flexible epidermal electronics to simultaneously achieve the electronic functions and mechanical flexibility. Mechanical intuition tells that the small size of the “island” is beneficial to the flexibility of the structure and the adaptability to complex geometric targets. Here, a plane-strain model and an axisymmetric model are established for square “island” and cycle “island,” respectively, to analyze the mechanical system consisting of the flexible epidermal electronics and the human skin. It is found that the pressure between the “island” and the human skin is positive at the inner region and reaches a peak value at the center, while is negative at the outer region and approaches infinite at the boundary of the contact region. With the increase in the size a/R0, the amplitude of the pressure significantly increases, as well as the singular degree of the pressure at the boundary. The reduction of the “island” size is beneficial for the optimization of the “comfort level” of the flexible epidermal electronics. The models degenerate into the famous Johnson-Kendall-Roberts (JKR) model for the limit case with extremely hard and thick “island.”