DDDeping Dong

Deping Dong

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Deping Dong has a total of 12 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Numerical Study on the Effect of Various Working Fluids on the Performance of Loop Heat Pipes Based on Two-Dimensional Simulation

    by Bo Shao, Bingyao Lin, Nanxi Li, Le Liu, Zhenhua Jiang, Deping Dong, Yinong Wu

    The computational fluid dynamics (CFD) method is often used to study heat and mass transfer mechanisms in loop heat pipes (LHPs). However, few numerical studies have been conducted on the entire loop heat pipe system. In this work, a two-dimensional simulation model of an LHP was developed. The wicking process was described using a capillary pressure model, implemented through user-defined functions (UDFs). The flow, phase change, and heat transfer processes vary with the change of the working fluid. Therefore, the effects of ammonia, propylene, and R245fa on the heat transfer performance of the LHP were analyzed in the simulation. According to the simulation results, the LHP charged with ammonia showed the best heat transfer performance, followed by the LHP charged with propylene, and the LHP charged with R245fa showed the worst heat transfer performance. The simulation results align with the predictions from figures of merit (FOMs). Moreover, the model provides detailed insights into the temperature field and vapor–liquid distribution during LHP operation. Experiments using an LHP with the three working fluids were also conducted to verify the model's accuracy. Regarding the influence of the working fluid and the heat load on LHP performance, the simulation model aligns with the experimental results.


  • Simulation and Experimental Study of Two-Phase Gas–Liquid Behavior in Two-Dimensional Porous Medium Based on Lattice Boltzmann Method

    by Shikang Yin, Zhenhua Jiang, Shuai Gong, Bingyao Lin, Deping Dong

    Loop heat pipe is a passive two-phase heat transfer device. The key component of the loop heat pipe is the evaporator. In this study, the gas–liquid two-phase behavior inside a two-dimensional porous medium with a single-pore size and multi-pore size distributions was comparatively studied, both experimentally and numerically by the lattice Boltzmann method. With a constant heat flux applied to the evaporator's shell, the wick initially fills with saturated liquid, then undergoes evaporation with vapor invasion, and partially dries out with a gas–liquid interface. Due to the multi-pore size distribution in porous medium, vapor is more easily expelled from the wick. There is a significant difference gas–liquid interface inside the wick between the single-pore size wick and the multi-pore size wick, and the temperature of the evaporator's shell of the multi-pore size wick is 27.6% lower than that of the single-pore size wick. To validate the numerical results, two loop heat pipes were built, including monoporous wick and biporous wick, respectively. The experiment found that under high power, the performance of loop heat pipe with biporous wick is significantly better than that of loop heat pipe with monoporous wick. The temperature of the biporous wick is 9.79 K lower than that of the monoporous wick at 230 W. Experiments and simulations show that the porous medium with multi-pore has better performance.


  • Open Access

    Numerical Investigation with Experimental Validation of Heat and Mass Transfer during Evaporation in the Porous Wick within a Loop Heat Pipe

    by Suzheng Zheng, Binyao Lin, Chenyang Zhao, Xue Zhou, Nanxi Li, Deping Dong

    The heat transfer performance of the evaporator significantly affects the heat transfer capacity of the loop heat pipe (LHP). The vapor blanket can be formed once the vapor penetrates the wick especially at high heat flux, resulting in an unsaturated state of the wick and deteriorating the evaporator performance. It is crucial to understand the liquid–vapor behavior for enhancing the LHP performance by investigating the fundamental heat and mass transfer in the wick with phase-change. However, previous modeling studies only considered a single-phase flow or complete saturation in the wick, and the capillary effect on the fluid states was rarely taken into account. The present work developed two mathematical models based on the assumptions of saturated and unsaturated wicks. The fluid states were analyzed at the liquid–vapor interface under the consideration of the capillary effect, and a pore-scale evaporation model was applied to study the phase change behavior and interfacial heat and mass transfer. The relative permeability was introduced to describe the two-phase flow in the porous wick, and the capillary force was modeled as a function of the local saturation in the two-phase region. The temperature results calculated by the models were compared with the experimental results, and the assumption that the vapor penetration leads to deterioration of evaporator performance at high heat flux was validated. Vapor blanket thickness can be estimated through the saturation profile, which provides a simple and effective method. It was also found that the capillary number ω was the key factor affecting the thickness of the vapor blanket. The greater the ω, the faster the vapor blanket thickness increases.