NLNanxi Li

Nanxi Li

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Nanxi Li has a total of 23 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Numerical Study on the Effect of Various Working Fluids on the Performance of Loop Heat Pipes Based on Two-Dimensional Simulation

    by Bo Shao, Bingyao Lin, Nanxi Li, Le Liu, Zhenhua Jiang, Deping Dong, Yinong Wu

    The computational fluid dynamics (CFD) method is often used to study heat and mass transfer mechanisms in loop heat pipes (LHPs). However, few numerical studies have been conducted on the entire loop heat pipe system. In this work, a two-dimensional simulation model of an LHP was developed. The wicking process was described using a capillary pressure model, implemented through user-defined functions (UDFs). The flow, phase change, and heat transfer processes vary with the change of the working fluid. Therefore, the effects of ammonia, propylene, and R245fa on the heat transfer performance of the LHP were analyzed in the simulation. According to the simulation results, the LHP charged with ammonia showed the best heat transfer performance, followed by the LHP charged with propylene, and the LHP charged with R245fa showed the worst heat transfer performance. The simulation results align with the predictions from figures of merit (FOMs). Moreover, the model provides detailed insights into the temperature field and vapor–liquid distribution during LHP operation. Experiments using an LHP with the three working fluids were also conducted to verify the model's accuracy. Regarding the influence of the working fluid and the heat load on LHP performance, the simulation model aligns with the experimental results.


  • Investigation on the Influence of the Condenser Length and Its Coupling Effect With Elevation on the Performance of Loop Heat Pipe

    by Xue Zhou, Suzheng Zheng, Nanxi Li, Bingyao Lin, De Chen, Zhenhua Jiang, Yan Lu

    The effects of condenser length and evaporator/condenser elevation on the performance of a loop heat pipe (LHP) in a gravity field were investigated, respectively, as well as their coupling effect. The refrigerant R40 was selected, and the condenser length was altered by changing the number of fins connected to the water-cooled plates. The experiments were conducted at three evaporator/condenser elevations: zero elevation, favorable elevation, and adverse elevation. The experimental results indicated that the evaporator temperatures of LHP with three different condenser lengths are very close when the LHP operates in variable conductance mode (VCM). However, an excessively long condenser will increase the LHP thermal resistance in VCM. In constant conductance mode (CCM), the longer the condenser, the lower the evaporator temperature. As the heat load increases, the LHP first exhibits gravity-driven mode and then capillarity-gravity-driven mode at a favorable elevation. The positive coupling effect on reducing the evaporator temperature by extending the condenser length and running at a favorable elevation manifests that the influence of condenser length is very small in gravity-driven mode, while in capillarity-gravity-driven mode, the effect of operating at a favorable elevation gets weakened, and the positive effects of the two factors cannot be simply calculated by the linear superposition principle. Additionally, reverse flow and flash evaporation were also observed and analyzed in depth. These results and conclusions can be used to guide the design of the condenser and the installation of LHP for ground applications.


  • Experimental Study on the Small Two-Phase Thermosyphon Loop With Minichannel Evaporator

    by Yang Liu, Zhe Yan, Zhenhua Jiang, Nanxi Li, Baoyu Yang, Yinong Wu

    This study experimentally investigates the small two-phase thermosyphon loop with a minichannel evaporator. The influences of heating power, fan power, and inclination angle on the heat transfer performance are presented, and the related mechanisms are revealed. Results show that the thermal resistance of the thermosyphon loop tends to decrease as the heating power is increased. It is found that there exists an optimal value of fan power. Interestingly, the invalidity behavior of thermosyphon under the inclination condition prefers to occur at higher heating power. To sum up, the small two-phase thermosyphon loop with a minichannel evaporator could produce excellent heat transfer performance with energy-saving characteristics, indicating its wide potential applications in the field of electronic chip cooling.


  • Open Access

    Numerical Investigation with Experimental Validation of Heat and Mass Transfer during Evaporation in the Porous Wick within a Loop Heat Pipe

    by Suzheng Zheng, Binyao Lin, Chenyang Zhao, Xue Zhou, Nanxi Li, Deping Dong

    The heat transfer performance of the evaporator significantly affects the heat transfer capacity of the loop heat pipe (LHP). The vapor blanket can be formed once the vapor penetrates the wick especially at high heat flux, resulting in an unsaturated state of the wick and deteriorating the evaporator performance. It is crucial to understand the liquid–vapor behavior for enhancing the LHP performance by investigating the fundamental heat and mass transfer in the wick with phase-change. However, previous modeling studies only considered a single-phase flow or complete saturation in the wick, and the capillary effect on the fluid states was rarely taken into account. The present work developed two mathematical models based on the assumptions of saturated and unsaturated wicks. The fluid states were analyzed at the liquid–vapor interface under the consideration of the capillary effect, and a pore-scale evaporation model was applied to study the phase change behavior and interfacial heat and mass transfer. The relative permeability was introduced to describe the two-phase flow in the porous wick, and the capillary force was modeled as a function of the local saturation in the two-phase region. The temperature results calculated by the models were compared with the experimental results, and the assumption that the vapor penetration leads to deterioration of evaporator performance at high heat flux was validated. Vapor blanket thickness can be estimated through the saturation profile, which provides a simple and effective method. It was also found that the capillary number ω was the key factor affecting the thickness of the vapor blanket. The greater the ω, the faster the vapor blanket thickness increases.


  • Experimental Investigation of a Loop Heat Pipe With R245fa and R1234ze(E) as Working Fluids

    by Guangming Xu, Rongjian Xie, Nanxi Li, Cheng Liu

    Two kinds of new refrigerant R1234ze(E) and R245fa were discussed as substitutes or supplements to traditional working fluids of loop heat pipes (LHPs) based on their favorable thermophysical properties and characteristics such as being safe and environmentally friendly. Thermal characteristics of a loop heat pipe with sintering copper wick at different charging ratios were experimentally investigated under variable heat loads. The results showed that the optimal charging ratio in the loop heat pipe range from 65% to 70%, and at this charging level, the R1234ze(E) system had better start-up response, while the R245fa system presented a stronger heat transfer capacity. The characteristic temperature of R1234ze(E) system was below 35 °C, and the corresponding thermal resistance was 0.08 K/W–1.62 K/W under heat loads ranging from 5 W to 40 W. The thermal resistance of the R245fa system was 0.18 K/W–0.91 K/W under heat loads of 10 W–60 W, and the operating temperature was below 60 °C. The loop heat pipes charged with the proposed new refrigerants exhibit superb performance in room temperature applications, making them beneficial for enhancing the performance of electronics and could provide a distinctive choice for the cooling of small-sized electronics especially.


  • Theoretical Analysis of Thin Film Evaporation in the Wicks of Loop Heat Pipes

    by Bingyao Lin, Nanxi Li, Shiyue Wang, Leren Tao, Guangming Xu, Yinong Wu

    In this paper, a thin film evaporation model that includes expressions for energy, mass, and momentum conservation was established through the augmented Young–Laplace model. Based on this model, the effects of pore size and superheating on heat transfer during thin film evaporation were analyzed. The influence of the wick diameter of the loop heat pipe (LHP) on the critical heat flux of the evaporator is analyzed theoretically. The results show that pore size and superheating mainly influence evaporation through changes in the length of the transition film and intrinsic meniscus. The contribution of the transition film area is mainly reflected in the heat transfer coefficient, and the contribution of the intrinsic meniscus area is mainly apparent in the quantity of heat that is transferred. When an LHP evaporator is operating in a state of surface evaporation, a higher heat transfer coefficient can be achieved using a smaller pore size.


  • Analysis of Condensation Flow Pattern and Heat Transfer of a Cryogenic Loop Heat Pipe With Different Heating Powers

    by Kaifen Yan, Nanxi Li, Yinong Wu, Rongjian Xie

    The cryogenic fluids’ flow performance and condensation characteristics with different heating powers in cryogenic loop heat pipes (CLHPs) have not been studied due to the difficulty of measurement at low temperature. In this study, a test system was designed and fabricated to characterize the condensation flow patterns of propylene CLHP and its heat transfer performance with different heating powers. The results show that the two-phase region length and flow pattern in the condenser were closely related to the operation mode of the CLHP. The vapor front in the condenser oscillated at the condenser inlet at a low heating power, which resulted in an unstable operation of the CLHP. Moreover, by comparing the condensation heat transfer coefficient (HTC) with the condensation correlations, the Cavallini correlation is recommended for the design of the CLHP condenser.