Yao Chen
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Yao Chen has a total of 26 co-authors. Here are the top co-authors by number of shared publications:
- Jeffrey Penfold
ISIS Facility, STFC, Rutherford Appleton Laboratory, Chilton, Didcot, OXON, UK
2 shared publications Kun Ma
ISIS Facility, Rutherford Appleton Laboratory, STFC, Didcot, OXON, UK OX11 0QX
2 shared publicationsZi Wang
School of Science, State Key Laboratory of Heavy Oil Processing, China University of Petroleum , Qingdao 266580, China
2 shared publicationsBruno Demé
Institut Laue-Langevin, Grenoble, France
1 shared publicationDavid W. Roberts
School of Pharmacy and Biomolecular Sciences, Liverpool John Moores University, Liverpool L3 3AF, UK
1 shared publication- Dong Guo
School of Health Science and Engineering, University of Shanghai for Science and Technology, Shanghai 200093, China
1 shared publication
Latest Publications
- 1 February 2022
- Published by Elsevier in Journal of Colloid and Interface Science
- Vol. 608 (Pt 1) , 405-415
Implications of surfactant hydrophobic chain architecture on the Surfactant-Skin lipid model interaction
- 1 February 2022
- Published by Elsevier in Journal of Colloid and Interface Science
- Vol. 608 (Pt 1) , 405-415
Implications of surfactant hydrophobic chain architecture on the Surfactant-Skin lipid model interaction
- 20 March 2010
- Published by Wiley in Clinical and Experimental Pharmacology and Physiology
- Vol. 37 (4) , 501-505
Development and validation of a simple and sensitive liquid chromatography–tandem mass spectrometry method for quantifying trimetazidine in human plasma
Summary: 1. A simple and sensitive liquid chromatography–tandem mass spectrometry (LC‐MS‐MS) method for quantifying trimetazidine in human plasma was developed and validated. Sample preparation was based on deproteinating with acetonitrile.2. Chromatography was performed on a C18 analytical column (5 μm; 150 × 2.1 mm i.d.) and the retention times for trimetazidine and cetirizine (used as the internal standard) were 1.8 and 3.0 min, respectively. The ionization was optimized using an electrospray ionization source and enhanced selectivity was achieved using tandem mass spectrometry. The calibration curve ranged from 0.1 to 200 ng/mL. The inter‐day precision, accuracy and the relative standard deviation (RSD) were all < 15%. The analyte was shown to be stable over the time‐scale of the entire procedure.3. The robustness of the method was demonstrated by the good reproducibility of the results obtained during the analysis of clinical samples.
- 20 March 2010
- Published by Wiley in Clinical and Experimental Pharmacology and Physiology
- Vol. 37 (4) , 501-505
Development and validation of a simple and sensitive liquid chromatography–tandem mass spectrometry method for quantifying trimetazidine in human plasma
Summary: 1. A simple and sensitive liquid chromatography–tandem mass spectrometry (LC‐MS‐MS) method for quantifying trimetazidine in human plasma was developed and validated. Sample preparation was based on deproteinating with acetonitrile.2. Chromatography was performed on a C18 analytical column (5 μm; 150 × 2.1 mm i.d.) and the retention times for trimetazidine and cetirizine (used as the internal standard) were 1.8 and 3.0 min, respectively. The ionization was optimized using an electrospray ionization source and enhanced selectivity was achieved using tandem mass spectrometry. The calibration curve ranged from 0.1 to 200 ng/mL. The inter‐day precision, accuracy and the relative standard deviation (RSD) were all < 15%. The analyte was shown to be stable over the time‐scale of the entire procedure.3. The robustness of the method was demonstrated by the good reproducibility of the results obtained during the analysis of clinical samples.