Development and validation of a simple and sensitive liquid chromatography–tandem mass spectrometry method for quantifying trimetazidine in human plasma
- 20 March 2010
- journal article
- research article
- Published by Wiley in Clinical and Experimental Pharmacology and Physiology
- Vol. 37 (4) , 501-505
Abstract
Summary: 1. A simple and sensitive liquid chromatography–tandem mass spectrometry (LC‐MS‐MS) method for quantifying trimetazidine in human plasma was developed and validated. Sample preparation was based on deproteinating with acetonitrile.2. Chromatography was performed on a C18 analytical column (5 μm; 150 × 2.1 mm i.d.) and the retention times for trimetazidine and cetirizine (used as the internal standard) were 1.8 and 3.0 min, respectively. The ionization was optimized using an electrospray ionization source and enhanced selectivity was achieved using tandem mass spectrometry. The calibration curve ranged from 0.1 to 200 ng/mL. The inter‐day precision, accuracy and the relative standard deviation (RSD) were all < 15%. The analyte was shown to be stable over the time‐scale of the entire procedure.3. The robustness of the method was demonstrated by the good reproducibility of the results obtained during the analysis of clinical samples.Keywords
This publication has 10 references indexed in Scilit:
- Sensitive and rapid LC–ESI-MS method for the determination of trimetazidine in human plasmaJournal of Pharmaceutical and Biomedical Analysis, 2007
- LC/ESI-MS method for the determination of trimetazidine in human plasma: Application to a bioequivalence study on Chinese volunteersJournal of Pharmaceutical and Biomedical Analysis, 2007
- An HPLC Determination of Trimetazidine in Human Plasma Using Liquid‐Liquid Extraction for Sample Clean‐UpJournal of Liquid Chromatography & Related Technologies, 2005
- Non‐extractive procedure followed by LC/APCI MS/MS analysis of trimetazidine in plasma samples for assessing bioequivalence of immediate/modified release formulationsBiomedical Chromatography, 2005
- Bioavailability and Bioequivalence: An FDA Regulatory OverviewPharmaceutical Research, 2001
- HIGH THROUGHPUT ASSAY METHOD FOR THE QUANTITATION OF TRIMETAZIDINE IN HUMAN PLASMA BY LC/MS, WITH SELECTED REACTION MONITORINGJournal of Liquid Chromatography & Related Technologies, 2001
- Guidance for robustness/ruggedness tests in method validationJournal of Pharmaceutical and Biomedical Analysis, 2001
- Trimetazidine: Potential Mechanisms of Action in Hypertrophic CardiomyopathyJournal of Cardiovascular Pharmacology, 1999
- Determination of trimetazidine in biological fluids by gas chromatography-mass spectrometryJournal of Chromatography B: Biomedical Sciences and Applications, 1989
- Trace determination of trimetazidine in plasma by high-performance liquid chromatography using fluorescence detectionJournal of Chromatography B: Biomedical Sciences and Applications, 1981