Michael Campbell
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Michael Campbell has a total of 269 co-authors. Here are the top co-authors by number of shared publications:
- Rafael Ballabriga
CERN, Geneva, Switzerland
17 shared publications - Xavier Llopart
CERN, 1211 Geneva 23, Switzerland
10 shared publications J. Alozy
Conseil Europen pour la recherche nuclaire (CERN), Meyrin, Switzerland
7 shared publications- Sergio Gomez Fernandez
ICCUB, Universitat de Barcelona
6 shared publications - David Gascon
Departament de Física Quàntica i Astrofísica (FQA) and Institut de Ciències del Cosmos (ICCUB), Universitat de Barcelona (UB), Martí i Franquès, 1, 08028 Barcelona, Spain
5 shared publications - Joan Mauricio
ICCUB, Universitat de Barcelona
5 shared publications
Latest Publications
- Open Access
- 30 April 2026
- Published by Elsevier in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
- Vol. 1090
Electron/hadron separation with the TRD based on GaAs pixel detectors
- 30 April 2026
- Published by Elsevier in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
- Vol. 1090
Open AccessElectron/hadron separation with the TRD based on GaAs pixel detectors
- 27 March 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Radiation and Plasma Medical Sciences
- Vol. PP (24697311) , 1
Below 100 ps CTR using FastIC+, an ASIC including on-chip digitization for ToF-PET and beyond
This work presents the 8-channel FastIC+, a low-power consumption and highly configurable multi-channel front-end ASIC with internal digitization, for the readout of photo-sensors with picosecond time resolution and intrinsic gain. This ASIC, manufactured in 65 nm CMOS technology, can readout positive or negative polarity sensors and provides a digitized measurement of the arrival time and energy of the detected events with a power consumption of 12.5 mW per channel. On-chip digitization is executed by a Time-to-Digital Converter (TDC) based on a Phase-Locked Loop (PLL) generating 16 phases at 1.28 GHz. The internal TDC introduces a jitter contribution of 31.3 ps FWHM, with minimal impact on timing measurements. When evaluating FastIC+ to readout 3×3 mm2 silicon photomultipliers (SiPMs) with a pulsed laser, we achieved a single-photon time resolution (SPTR) of (98 ± 1) ps FWHM.We also performed time-of-flight positron emission tomography (ToF-PET) experiments using scintillator crystals of different sizes and materials. With LYSO:Ce,Ca crystals of 2.8×2.8×20 mm3 we obtained a coincidence time resolution (CTR) of (130 ± 1) ps FWHM. With LGSO crystals of 2×2×3 mm3, a CTR of (85 ± 1) ps FWHM. To the best of our knowledge, this is the first time that a CTR below 100 ps using on-chip digitization is reported.
- 27 March 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Radiation and Plasma Medical Sciences
- Vol. PP (24697311) , 1
Below 100 ps CTR using FastIC+, an ASIC including on-chip digitization for ToF-PET and beyond
This work presents the 8-channel FastIC+, a low-power consumption and highly configurable multi-channel front-end ASIC with internal digitization, for the readout of photo-sensors with picosecond time resolution and intrinsic gain. This ASIC, manufactured in 65 nm CMOS technology, can readout positive or negative polarity sensors and provides a digitized measurement of the arrival time and energy of the detected events with a power consumption of 12.5 mW per channel. On-chip digitization is executed by a Time-to-Digital Converter (TDC) based on a Phase-Locked Loop (PLL) generating 16 phases at 1.28 GHz. The internal TDC introduces a jitter contribution of 31.3 ps FWHM, with minimal impact on timing measurements. When evaluating FastIC+ to readout 3×3 mm2 silicon photomultipliers (SiPMs) with a pulsed laser, we achieved a single-photon time resolution (SPTR) of (98 ± 1) ps FWHM.We also performed time-of-flight positron emission tomography (ToF-PET) experiments using scintillator crystals of different sizes and materials. With LYSO:Ce,Ca crystals of 2.8×2.8×20 mm3 we obtained a coincidence time resolution (CTR) of (130 ± 1) ps FWHM. With LGSO crystals of 2×2×3 mm3, a CTR of (85 ± 1) ps FWHM. To the best of our knowledge, this is the first time that a CTR below 100 ps using on-chip digitization is reported.
- Open Access
- 16 November 2025
- Published by Elsevier in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
- Vol. 1083
Characterisation of the Timepix4 silicon sensor detector for low energy X-ray applications
- 16 November 2025
- Published by Elsevier in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
- Vol. 1083
Open AccessCharacterisation of the Timepix4 silicon sensor detector for low energy X-ray applications
- Open Access
A Sensor Employing an Array of Silicon Photomultipliers for Detection of keV Ions in Time-of-Flight Mass Spectrometry
Pixellated scintillation detectors have the potential to overcome several limitations of conventional microchannel-plate-based detectors employed in time-of-flight mass spectrometry (ToF-MS), such as extending detector lifetime, reducing vacuum requirements, or increasing the ion throughput. We have developed a prototype comprising a fast organic scintillator (Exalite 404) coupled to an array of 16 silicon photomultipliers (SiPMs), with read-out electronics based on the FastIC application-specific integrated circuit (ASIC). Each SiPM signal processed by FastIC is fed into its own time-to-digital converter (TDC). The dead time of a single channel can be as short as ∼20 ns. As a result, our system have the potential to process ion rates above cm−2 s−1. We have evaluated the performance of our prototype using a velocity-map imaging ToF-MS instrument, recording the time-of-flight mass spectra of C3H6 and CF3I samples. We achieved time resolutions of () and () ns FWHM for ions of mass-to-charge ratio () values of 196 and 18, respectively. This corresponds to a mass resolution of ∼1000 for , which we found to be dominated by the spread in ion arrival times.Open AccessA Sensor Employing an Array of Silicon Photomultipliers for Detection of keV Ions in Time-of-Flight Mass Spectrometry
Pixellated scintillation detectors have the potential to overcome several limitations of conventional microchannel-plate-based detectors employed in time-of-flight mass spectrometry (ToF-MS), such as extending detector lifetime, reducing vacuum requirements, or increasing the ion throughput. We have developed a prototype comprising a fast organic scintillator (Exalite 404) coupled to an array of 16 silicon photomultipliers (SiPMs), with read-out electronics based on the FastIC application-specific integrated circuit (ASIC). Each SiPM signal processed by FastIC is fed into its own time-to-digital converter (TDC). The dead time of a single channel can be as short as ∼20 ns. As a result, our system have the potential to process ion rates above cm−2 s−1. We have evaluated the performance of our prototype using a velocity-map imaging ToF-MS instrument, recording the time-of-flight mass spectra of C3H6 and CF3I samples. We achieved time resolutions of () and () ns FWHM for ions of mass-to-charge ratio () values of 196 and 18, respectively. This corresponds to a mass resolution of ∼1000 for , which we found to be dominated by the spread in ion arrival times. - Open Access
- 10 January 2025
- Published by Elsevier in Physics Letters B
- Vol. 861
Bounding elastic photon-photon scattering at s≈1 MeV using a laser-plasma platform
- 10 January 2025
- Published by Elsevier in Physics Letters B
- Vol. 861
Open AccessBounding elastic photon-photon scattering at s≈1 MeV using a laser-plasma platform
- Open Access
- 1 July 2024
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 19 (07) , P07021
Timing resolution performance of Timepix4 bump-bonded assemblies
The timing performance of the Timepix4 application-specific integrated circuit (ASIC) bump-bonded to a 100 μm thick n-on-p silicon sensor is presented. A picosecond pulsed infrared laser was used to generate electron-hole pairs in the silicon bulk in a repeatable fashion, controlling the amount, position and time of the stimulated charge signal. The timing resolution for a single pixel has been measured to 107 ps r.m.s. for laser-stimulated signals in the silicon sensor bulk. Considering multi-pixel clusters, the measured timing resolution reached 33 ps r.m.s. exploiting oversampling of the timing information over several pixels.
- 1 July 2024
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 19 (07) , P07021
Open AccessTiming resolution performance of Timepix4 bump-bonded assemblies
The timing performance of the Timepix4 application-specific integrated circuit (ASIC) bump-bonded to a 100 μm thick n-on-p silicon sensor is presented. A picosecond pulsed infrared laser was used to generate electron-hole pairs in the silicon bulk in a repeatable fashion, controlling the amount, position and time of the stimulated charge signal. The timing resolution for a single pixel has been measured to 107 ps r.m.s. for laser-stimulated signals in the silicon sensor bulk. Considering multi-pixel clusters, the measured timing resolution reached 33 ps r.m.s. exploiting oversampling of the timing information over several pixels.
- Open Access
- 14 June 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Radiation and Plasma Medical Sciences
- Vol. 8 (7) , 718-733
Toward Sub-100 ps TOF-PET Systems Employing the FastIC ASIC With Analog SiPMs
Time-of-flight positron emission tomography (TOF-PET) scanners demand electronics that are power-efficient, low-noise, cost-effective, and possess a large bandwidth. Recent developments have demonstrated sub-100 ps time resolution with elevated power consumption per channel, rendering this unfeasible to build a scanner. In this work, we evaluate the performance for TOF-PET of the FastIC front-end using different scintillators and silicon photomultipliers (SiPMs). FastIC is an 8-channel ASIC developed in CMOS 65 nm capable of measuring the energy and the arrival time of a detected pulse with 12 mW per channel. Using Hamamatsu SiPMs (S13360-3050PE) coupled to LSO:Ce:0.2%Ca crystals of 2 × 2 × 3 mm and LYSO:Ce:0.2%Ca of 3.13 × 3.13 × 20 mm, we measured a CTR of (95 ± 3) ps and 156 ± 4) ps FWHM, respectively. With FBK NUV-HD LF2 M0 SiPMs coupled to the same crystals, we obtained a CTR of (76 ± 2) ps and (127 ± 3) ps FWHM. We employed FastIC with a TlCl pure Cherenkov emitter, demonstrating time resolutions comparable to those achieved with high-power-consuming electronics. These findings shows that FastIC represents a cost-effective alternative that can significantly enhance the time resolution of current TOF-PET systems while maintaining low power consumption.
- 14 June 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Radiation and Plasma Medical Sciences
- Vol. 8 (7) , 718-733
Open AccessToward Sub-100 ps TOF-PET Systems Employing the FastIC ASIC With Analog SiPMs
Time-of-flight positron emission tomography (TOF-PET) scanners demand electronics that are power-efficient, low-noise, cost-effective, and possess a large bandwidth. Recent developments have demonstrated sub-100 ps time resolution with elevated power consumption per channel, rendering this unfeasible to build a scanner. In this work, we evaluate the performance for TOF-PET of the FastIC front-end using different scintillators and silicon photomultipliers (SiPMs). FastIC is an 8-channel ASIC developed in CMOS 65 nm capable of measuring the energy and the arrival time of a detected pulse with 12 mW per channel. Using Hamamatsu SiPMs (S13360-3050PE) coupled to LSO:Ce:0.2%Ca crystals of 2 × 2 × 3 mm and LYSO:Ce:0.2%Ca of 3.13 × 3.13 × 20 mm, we measured a CTR of (95 ± 3) ps and 156 ± 4) ps FWHM, respectively. With FBK NUV-HD LF2 M0 SiPMs coupled to the same crystals, we obtained a CTR of (76 ± 2) ps and (127 ± 3) ps FWHM. We employed FastIC with a TlCl pure Cherenkov emitter, demonstrating time resolutions comparable to those achieved with high-power-consuming electronics. These findings shows that FastIC represents a cost-effective alternative that can significantly enhance the time resolution of current TOF-PET systems while maintaining low power consumption.
- Open Access
High-rate, high-resolution single photon X-ray imaging: Medipix4, a large 4-side buttable pixel readout chip with high granularity and spectroscopic capabilities
The Medipix4 chip is the latest member in the Medipix/Timepix family of hybrid pixel detector chips aimed at high-rate spectroscopic X-ray imaging using high-Z materials. It can be tiled on all 4 sides making it ideal for constructing large-area detectors with minimal dead area. The chip is designed to read out a sensor of 320 x 320 pixels with dimensions of 75 {\mu}m x 75 {\mu}m or 160 x 160 pixels with dimensions of 150 {\mu}m x 150 {\mu}m. The readout architecture features energy binning of the single photons, which includes charge sharing correction for hits with energy spread over adjacent pixels. This paper presents the specifications, architecture, and circuit implementation of the chip, along with the first electrical measurements.
Open AccessHigh-rate, high-resolution single photon X-ray imaging: Medipix4, a large 4-side buttable pixel readout chip with high granularity and spectroscopic capabilities
The Medipix4 chip is the latest member in the Medipix/Timepix family of hybrid pixel detector chips aimed at high-rate spectroscopic X-ray imaging using high-Z materials. It can be tiled on all 4 sides making it ideal for constructing large-area detectors with minimal dead area. The chip is designed to read out a sensor of 320 x 320 pixels with dimensions of 75 {\mu}m x 75 {\mu}m or 160 x 160 pixels with dimensions of 150 {\mu}m x 150 {\mu}m. The readout architecture features energy binning of the single photons, which includes charge sharing correction for hits with energy spread over adjacent pixels. This paper presents the specifications, architecture, and circuit implementation of the chip, along with the first electrical measurements.
- Open Access
- 18 November 2023
- Published by Springer Nature in Experimental Astronomy
- Vol. 56 (2-3) , 371-402
Relativistic particle measurement in jupiter’s magnetosphere with Pix.PAN
Pix.PAN is a compact cylindrical magnetic spectrometer, intended to provide excellent high energy particle measurements under high rate and hostile operating conditions in space. Its principal design is composed of two Halbach-array magnetic sectors and six Timepix4-based tracking layers; the latest hybrid silicon pixel detector readout ASIC designed. Due to Pix.PAN’s compact and relatively simple design, it has the potential to be used for space missions exploring with measurements of unprecedented precision, high energy particles in radiation belts and the heliophere (solar energetic particles, anomalous and galactic cosmic rays). In this white paper, we discuss the design and expected performance of Pix.PAN for COMPASS (Comprehensive Observations of Magnetospheric Particle Acceleration, Sources, and Sinks), a mission concept submitted to NASA’s Call “B.16 Heliophysics Mission Concept Studies (HMCS)” in 2021 that targets the extreme high energy particle environment of Jupiter’s inner radiation belts. We also discuss PixPAN’s operational conditions and interface requirements. The conceptual design shows that is possible to achieve an energy resolution of<12% for electrons in the range of 10 MeV-1 GeV and<35% for protons between $$\sim $$ 200 MeV to a few GeV. Due to the timestamp precision of Timepix4, a time resolution (on an instrument level) of about 100 ps can be achieved for time-of-flight measurements. In the most intense radiation environments of the COMPASS mission, Pix.PAN is expected to have a maximum hit rate of 44 $$\frac{\text {MHz}}{\text {cm}^2}$$ which is below the design limit of 360 $$\frac{\text {MHz}}{\text {cm}^2}$$ of Timepix4. Finally, a sensor design is proposed which allows the instrument to operate with a power budget of 20W without the loss of scientific performance.- 18 November 2023
- Published by Springer Nature in Experimental Astronomy
- Vol. 56 (2-3) , 371-402
Open AccessRelativistic particle measurement in jupiter’s magnetosphere with Pix.PAN
Pix.PAN is a compact cylindrical magnetic spectrometer, intended to provide excellent high energy particle measurements under high rate and hostile operating conditions in space. Its principal design is composed of two Halbach-array magnetic sectors and six Timepix4-based tracking layers; the latest hybrid silicon pixel detector readout ASIC designed. Due to Pix.PAN’s compact and relatively simple design, it has the potential to be used for space missions exploring with measurements of unprecedented precision, high energy particles in radiation belts and the heliophere (solar energetic particles, anomalous and galactic cosmic rays). In this white paper, we discuss the design and expected performance of Pix.PAN for COMPASS (Comprehensive Observations of Magnetospheric Particle Acceleration, Sources, and Sinks), a mission concept submitted to NASA’s Call “B.16 Heliophysics Mission Concept Studies (HMCS)” in 2021 that targets the extreme high energy particle environment of Jupiter’s inner radiation belts. We also discuss PixPAN’s operational conditions and interface requirements. The conceptual design shows that is possible to achieve an energy resolution of<12% for electrons in the range of 10 MeV-1 GeV and<35% for protons between $$\sim $$ 200 MeV to a few GeV. Due to the timestamp precision of Timepix4, a time resolution (on an instrument level) of about 100 ps can be achieved for time-of-flight measurements. In the most intense radiation environments of the COMPASS mission, Pix.PAN is expected to have a maximum hit rate of 44 $$\frac{\text {MHz}}{\text {cm}^2}$$ which is below the design limit of 360 $$\frac{\text {MHz}}{\text {cm}^2}$$ of Timepix4. Finally, a sensor design is proposed which allows the instrument to operate with a power budget of 20W without the loss of scientific performance.