CXChao Xing

Chao Xing

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Chao Xing has a total of 8 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Traction Network Protection Based on Similarity of Transient Current Waveform

    by Shilong Chen, Zihang Zhang, Hao Liu, Guihong Bi, Chao Xing, Pengsong Li, Wenying Zhang

    In this paper, a protection scheme for the traction network of the penetrating co-phase traction direct power supply system based on the waveform similarity at both ends of line is proposed. Besides, research on the transmission characteristics of fault current is also carried out. This article, from the perspectives of the reflection and refraction process, attenuation degree, and polarity of fault current, analyzes the correlation and difference of current waveforms at both ends when interior line faults and adjacent line faults emerge. The correlation of waveforms can be proved by cosine similarity after the process of synchronous squeezes wavelet transformation of fault current. The conclusions are as follows: when the interior line faults occur, the sequence, reflection and refraction process, and attenuation degree reaching both ends are roughly the same, the polarity change direction is the same, and the waveform similarity is high; when the adjacent line faults occur, the sequence, reflection and refraction process, and attenuation degree reaching at both ends are greatly different, the polarity change direction is opposite, and the waveform similarity is low. When a protection scheme is based on using cosine similarity, it can quickly and accurately identify internal or external current faults. Simulation results show that the proposed algorithm can meet the requirements of rapidity, selectivity, and reliability and is not affected by transition resistance and fault inception angles, so it has an application prospect to a certain degree.


  • Open Access

    A rolling optimization method of reserve capacity considering wind power frequency control

    by Chao Xing, Xinze Xi, Shengnan Li

    Wind power participating in frequency control with reserve capacity is an inevitable requirement for the system with a high proportion of wind power in the future. The existing reserve allocation methods, which consider the wind farm frequency control with reserve often only considered the economy or efficiency of the wind farm to set reserve capacity in fixed percentage, failed to follow the principle of optimal system efficiency and cannot optimize the system frequency regulation economy and frequency stability at the same time. The proposed method from the perspective of the system allocates reserve capacity among wind power, thermal power, and hydropower, who participate in system frequency control. Multi-objective chance constrained programming takes the economy and frequency stability as the optimization objectives. A rolling optimization method of reserve capacity is carried out periodically according to fluctuating wind power and load, making the calculation results in real time. A hybrid intelligent algorithm is adopted to improve the calculation efficiency. The simulation in the IEEE 39-bus test network shows that the proposed method can effectively improve the frequency control effect and system economy. Compared with the reserve allocation method considering wind farm participating in frequency control with reserve capacity in fixed percentage, the proposal can at most reduce the RoCoF by 9.5%, the maximum frequency deviation by 4.3%, and the steady-state frequency deviation by 4.1%, and when the system frequency stability is the only objective, at most 79.4% coal consumption reserve cost in the system can be saved.


  • Open Access

    Research on a Fault Location Method for a Pole-to-Pole Short-Circuit Fault in an LCC-MMC Hybrid DC Transmission System

    by Chao Xing, Shengnan Li, Xinze Xi

    When a pole-to-pole short-circuit fault occurs in an LCC-MMC hybrid DC transmission system, the fault characteristics are affected by the distributed capacitance and the transition resistance that cause a dead zone in the fault location and poor accuracy in determining the fault location. In view of this, this paper proposes a fault location method for the LCC-MMC hybrid DC transmission system. By analyzing the fault characteristics of the rectifier station and inverter station, the fault circuit equation of the rectifier side is analyzed, and the relationship between the fault distance and the transition resistance is deduced. The fault circuit of the inverter side is isolated by blocking CDSM-MMC, which can clear the fault current on the inverter side and thus eliminate the influence of the transition resistance. The steady-state fault information of the LCC DC outlet is used to eliminate the effect of distributed capacitance and achieve an accurate fault location. The LCC-MMC hybrid DC transmission system model is built on the PSCAD / EMTDC simulation platform. Simulation results show that the proposed fault location method can effectively avoid the transition resistance and distributed capacitance influences and thus obtain high fault location accuracy. Moreover, an accurate fault location can be achieved with a narrow fault data window length.