Chaofan Dong
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Chaofan Dong has a total of 9 co-authors. Here are the top co-authors by number of shared publications:
- Yangjun Zhang
State Key Laboratory of Automotive Safety and Energy, Tsinghua University, Beijing, China
4 shared publications Weilin Zhuge
State Key Laboratory of Automotive Safety and Energy, School of Vehicle and Mobility, Tsinghua University, Beijing, China
2 shared publications- Weilin Zhuge
State Key Laboratory of Automotive Safety and Energy, School of Vehicle and Mobility, Tsinghua University, Beijing 100084, China
2 shared publications - Xuanyang Hu
School of Vehicle and Mobility, Tsinghua University , Haidian District, Beijing 100080, China
2 shared publications Yuping Qian
State Key Laboratory of Automotive Safety and Energy, School of Vehicle and Mobility, Tsinghua University, Beijing, China
2 shared publications- Yuping Qian
State Key Laboratory of Intelligent Green Vehicle and Mobility, Tsinghua University, Beijing, China
2 shared publications
Latest Publications
- 22 December 2022
- Published by ASME International in Journal of Engineering for Gas Turbines and Power
- Vol. 145 (5)
Aerodynamic Design of Cooling Guide for Electrical Machine in Electric Ducted Fan
Electric ducted fan has newly emerged as the most compact type of propulsion fan for flying cars, because of its flexible configuration arrangement, low noise level and high safety level operation. Typically, an electric ducted fan is composed of a hub-driven fan and a hub-mounted inner rotor electrical machine. The thermal management of the hub-mounted electrical machine is essential because it determines the machine's continuous output power and reliability, as well as the fan thrust force. The heat transmitted from the stator winding to the cooling guide vane (CGV) is dissipated by introducing the air flow at hub region to the CGV. Therefore, in order to better improve the thermal performance of the CGV, an aerodynamic design of CGV is proposed in this paper for better thermal management of stator end-windings. First, for a certain desired power output of electrical machine under temperature constraints of stator winding, lumped thermal network is established to derive the requirement of heat transfer coefficients of the CGV. Then, from engineering feasibility, three different CGVs including straight type, arc-shape type and airfoil-shape type are tested by computational fluid dynamics. The evaluation of the CGV designs include the flow characteristics, power requirements, and thermal characteristics for stator winding cooling purposes. In comparison with the conventionally straight type CGV, improvements are gained from the designed arc-shape type and airfoil-shape type cooling configurations, whereas the fan thrust force remains the same simultaneously. It is verified that the arc-shape type and airfoil-shape type CGVs are promising in enhancing the thermal management performance of the electrical machine stator winding without power requirement.
- 22 December 2022
- Published by ASME International in Journal of Engineering for Gas Turbines and Power
- Vol. 145 (5)
Aerodynamic Design of Cooling Guide for Electrical Machine in Electric Ducted Fan
Electric ducted fan has newly emerged as the most compact type of propulsion fan for flying cars, because of its flexible configuration arrangement, low noise level and high safety level operation. Typically, an electric ducted fan is composed of a hub-driven fan and a hub-mounted inner rotor electrical machine. The thermal management of the hub-mounted electrical machine is essential because it determines the machine's continuous output power and reliability, as well as the fan thrust force. The heat transmitted from the stator winding to the cooling guide vane (CGV) is dissipated by introducing the air flow at hub region to the CGV. Therefore, in order to better improve the thermal performance of the CGV, an aerodynamic design of CGV is proposed in this paper for better thermal management of stator end-windings. First, for a certain desired power output of electrical machine under temperature constraints of stator winding, lumped thermal network is established to derive the requirement of heat transfer coefficients of the CGV. Then, from engineering feasibility, three different CGVs including straight type, arc-shape type and airfoil-shape type are tested by computational fluid dynamics. The evaluation of the CGV designs include the flow characteristics, power requirements, and thermal characteristics for stator winding cooling purposes. In comparison with the conventionally straight type CGV, improvements are gained from the designed arc-shape type and airfoil-shape type cooling configurations, whereas the fan thrust force remains the same simultaneously. It is verified that the arc-shape type and airfoil-shape type CGVs are promising in enhancing the thermal management performance of the electrical machine stator winding without power requirement.
- Open Access
Thermal Benefits of a Cooling Guide Vane for an Electrical Machine in an Electric Ducted Fan
Equipped with a distributed electric propulsion system, eVTOL is the primary vehicle for future urban air mobility. The electrical machine determines the weight of the distributed electric propulsion system, and the cooling capability determines the electrical machine’s weight. The electrical machine with air cooling is preferred for eVTOL due to its simplicity and light weight. This paper presents a new air-cooling system for an electrical machine in an electric ducted fan propulsion system. The novel cooling system consists of a cooling guide vane with a heat pipe (CGVHP), which is located downstream of the ducted fan rotating blade. The heated end of the heat pipe is inserted into the stator end windings and the cold end is inserted into the cooling guide vane. The heat generated in the windings is transmitted to the cooling guide vane by the heat pipe and dissipated by the forced convection using low-temperature air passing through the ducted fan. The cooling performance of the cooling guide vane with the heat pipe was numerically simulated, considering several critical design factors. The simulation results showed that the proposed CGVHP can be helpful for reducing the winding temperature of the electrical machine by over 25.5 °C at the peak power condition of 15.7 kW.
Open AccessThermal Benefits of a Cooling Guide Vane for an Electrical Machine in an Electric Ducted Fan
Equipped with a distributed electric propulsion system, eVTOL is the primary vehicle for future urban air mobility. The electrical machine determines the weight of the distributed electric propulsion system, and the cooling capability determines the electrical machine’s weight. The electrical machine with air cooling is preferred for eVTOL due to its simplicity and light weight. This paper presents a new air-cooling system for an electrical machine in an electric ducted fan propulsion system. The novel cooling system consists of a cooling guide vane with a heat pipe (CGVHP), which is located downstream of the ducted fan rotating blade. The heated end of the heat pipe is inserted into the stator end windings and the cold end is inserted into the cooling guide vane. The heat generated in the windings is transmitted to the cooling guide vane by the heat pipe and dissipated by the forced convection using low-temperature air passing through the ducted fan. The cooling performance of the cooling guide vane with the heat pipe was numerically simulated, considering several critical design factors. The simulation results showed that the proposed CGVHP can be helpful for reducing the winding temperature of the electrical machine by over 25.5 °C at the peak power condition of 15.7 kW.
- 5 September 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industry Applications
- Vol. 59 (1) , 699-711
Thermal Management Integrated With Flat Heat Pipes for In-Slot Stator Windings of Electric Motors
Increasing electromagnetic loads can improve the torque density and power density of electric motors; however, these enhancements are limited by the resultant thermal problems. This paper proposes a cooling concept, where flat heat pipes are inserted into the center of the stator slots to directly remove copper loss without consuming power. Detailed thermal models of the flat heat pipes and an electric motor are established using a lumped-parameter thermal network. The thickness of the vapor chamber is found to be the most critical parameter that simultaneously affects the thermal and electromagnetic performance. A case study is carried out on an existing 6-kW drive motor for a ducted fan, and the simulation results are validated through motorette experiments. Research results have shown that a 70°C hot-spot temperature reduction can be achieved, and more than 80% of the copper loss can be removed by the flat heat pipes. Moreover, the shaft power that the thermally modified motor can provide is expected to be 2.4 times that of the reference motor, and a continuous power density of 4.8 kW/kg can be achieved using air as a cooling agent.
- 5 September 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industry Applications
- Vol. 59 (1) , 699-711
Thermal Management Integrated With Flat Heat Pipes for In-Slot Stator Windings of Electric Motors
Increasing electromagnetic loads can improve the torque density and power density of electric motors; however, these enhancements are limited by the resultant thermal problems. This paper proposes a cooling concept, where flat heat pipes are inserted into the center of the stator slots to directly remove copper loss without consuming power. Detailed thermal models of the flat heat pipes and an electric motor are established using a lumped-parameter thermal network. The thickness of the vapor chamber is found to be the most critical parameter that simultaneously affects the thermal and electromagnetic performance. A case study is carried out on an existing 6-kW drive motor for a ducted fan, and the simulation results are validated through motorette experiments. Research results have shown that a 70°C hot-spot temperature reduction can be achieved, and more than 80% of the copper loss can be removed by the flat heat pipes. Moreover, the shaft power that the thermally modified motor can provide is expected to be 2.4 times that of the reference motor, and a continuous power density of 4.8 kW/kg can be achieved using air as a cooling agent.
- 17 June 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Transportation Electrification
- Vol. 6 (4) , 1386-1400
A Review of Thermal Designs for Improving Power Density in Electrical Machines
More electric aircraft is a promising solution to the problems of fuel consumption, emissions, and noise faced by the aviation industry. Electrical machines with high power density are essential to improve the overall performance of more electric aircraft. The huge difference between the maximum and the rated output of electrical machines shows that the performance does not reach the present limit of the electromagnetic design. Improving thermal designs is an important and effective way to increase power density at the present stage, as the temperature rise limit of materials is the main obstacle to restricting the performance of electrical machines. In this article, a variety of thermal designs are comprehensively reviewed and critically discussed according to different cooling positions. Next, an analysis of suitable thermal designs for different applications of electrical machines in more electric aircraft is presented. Subsequently, cooling capacity and additional mass of the thermal designs, which are the two key determinants of improving power density, are estimated and compared. Moreover, the reliability and cost of the thermal designs are discussed in depth. This work contributes to a thorough understanding of thermal designs in improving the power density of electrical machines and guides their future designs and applications in more electric aircraft.
- 17 June 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Transportation Electrification
- Vol. 6 (4) , 1386-1400
A Review of Thermal Designs for Improving Power Density in Electrical Machines
More electric aircraft is a promising solution to the problems of fuel consumption, emissions, and noise faced by the aviation industry. Electrical machines with high power density are essential to improve the overall performance of more electric aircraft. The huge difference between the maximum and the rated output of electrical machines shows that the performance does not reach the present limit of the electromagnetic design. Improving thermal designs is an important and effective way to increase power density at the present stage, as the temperature rise limit of materials is the main obstacle to restricting the performance of electrical machines. In this article, a variety of thermal designs are comprehensively reviewed and critically discussed according to different cooling positions. Next, an analysis of suitable thermal designs for different applications of electrical machines in more electric aircraft is presented. Subsequently, cooling capacity and additional mass of the thermal designs, which are the two key determinants of improving power density, are estimated and compared. Moreover, the reliability and cost of the thermal designs are discussed in depth. This work contributes to a thorough understanding of thermal designs in improving the power density of electrical machines and guides their future designs and applications in more electric aircraft.