RSRajshri J. Satputaley

Rajshri J. Satputaley

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Rajshri J. Satputaley has a total of 20 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Improving DC-Bus Voltage Regulation in Grid Fed EV Fast Charging Station Using MLI Based DVR

    by S. Manmadha Rao, R. J. Satputaley, R. K. Keshri, V. B. Borghate, Anurag Khergade

    This article presents a T-type 5-level inverter based dynamic voltage restorer (DVR) as a power quality (PQ) solution to enhance DC-bus voltage regulation in grid fed electric vehicle fast charging stations (EVFCS). The designing of DVR connected EVFCS is carried out in this work. There is a noticeable impact of EV loading on EVFCS performance. To observe the effect of EVs loading on DC-bus, three Li-ion battery packs are used. The performance of closed loop current regulated buck converters is examined for various loading scenarios. Further, the impact of EVs loading on several EVFCS parameters, including DC-bus voltage, charging current, battery SOC and battery voltage is examined in simulation. A closed loop voltage controller based on the αβ to dq transformation is constructed for 1-φ DVR in order to reduce the loading effect of EVs. This DVR maintains the rated DC-bus voltage (110 V), guaranteeing proper voltage regulation and the rated current of each battery under all three loading scenarios. Additionally, the DVR protects the point of common coupling (PCC) from voltage harmonics generated by EVFCS and maintains it within the IEEE 519 limit. Finally, to validate the simulation results, an experimental study is also carried out on reduced scale with a T-type 5-level DVR to observe the improved performance of EVFCS.


  • Performance Evaluation of MLI Based DVR in Grid Fed EV Fast Charging Station

    by S. Manmadha Rao, R. J. Satputaley, R. K. Keshri, Giuseppe Buja

    This article proposes a power quality (PQ) solution for the compensation of voltage sag on grid fed electric vehicle fast charging stations (EVFCS) using a T-type 5-level inverter based dynamic voltage restorer (DVR). In this work, a lithium-ion battery pack with a rating of 48 V, 10 Ah, and 5 A is used as an electric vehicle (EV) battery. Firstly, the voltage sag shows a significant effect on the performance of EVFCS. The analysis of the effect of voltage sag on different characteristics of EVFCS, such as DC-bus voltage, battery current, state-of-charge (SOC), and battery voltage, is carried out in MATLAB/Simulink and through experimentation. Further, the design of the charging system is carried out using a 1- $ \phi$ rectifier and DC-DC converter with closed loop current control. The performance of a closed loop current controlled buck converter is investigated experimentally for different magnitudes of sag (0%, 25% and 50%). Furthermore, the $ \alpha \beta$ to dq transformation based synchronous reference frame (SRF) theory operated closed loop voltage controller is employed for 1- $ \phi$ DVR to mitigate a voltage sag of 50%. This DVR maintains rated DC-bus voltage (110 V) and rated battery current (5 A) under a severe voltage sag condition of 50%. Also, DVR protects the PCC (grid) from voltage harmonics generated by the EVFCS, reducing the PCC voltage THD to 2.42% from 9.8%. Moreover, the control strategies of both the buck converter and DVR are developed on the hardware platform using the STM32 microcontroller. The simulation results are validated mathematically and experimentally. Lastly, simulation and experimental results confirm the beneficial use of T-type 5-level DVR for better performance of EVFCS.


  • Design and Implementation of Three Phase TCHB-Based DVR

    by Rajshri Satputaley, V. B. Borghate, Anurag Khergade, Ashwin Dhabale, S. K. Patro


  • A Review on Strategies to Control Frequency Variation in Deviation Settlement Mechanism

    by Srikant R. Sabbanwar, Rajshri J. Satputaley, Vijay B. Borghate

    Availability based tariff (ABT) came into power in India to overcome stability issues of grid. The grid was undisciplined due to large variation of power frequency due to unscheduled over injection and under injection of power without worrying about the frequency. However, the ABT was introduced to increase the generation capacity of grid but it has been slowly adopted as profit making system. Now, (Deviation Settlement Mechanism) DSM has been introduced in India as a frequency-based technique and does not depends on any real world market conditions. The frequency deviation describes the over/ under injection of power that feeds to DSM penalty. This review paper deals with the recent studies carried out in drawing down the strategies to discourage deviation (frequency) from schedule, operation within frequency band and by ensuring grid security. In addition to this, a basic control strategy has also been reviewed that can be adopted in implementing a topology for control over frequency variation from generation end. This paper deals with the basic discussions over implementation of DSM as per guidelines of CERC and MERC and few possible power devices and its methods to control frequency variation based on some past researches.


  • Voltage Sag Mitigation using DVR in Grid fed EV Fast Charging Station

    by S. Manmadha Rao, R. J. Satputaley, R. K. Keshri, N. R. Patne, G. Buja

    This paper presents a model of electric vehicle fast charging station (EVFCS) connected to the grid. Impact of supply side voltage sag on the process of charging of an electric vehicle (EV) connected to EVFCS is studied. Behaviour of quantities relevant to the process such as DC link voltage, charging current, state-of-charge (SOC) and voltage of battery are investigated using MATLAB/Simulink. A dynamic voltage restorer (DVR) based on 5-level transistor-clamped H-bridge (TCHB) inverter is used to mitigate the voltage sag and to improve the performance of EVFCS. The simulation results shows the beneficial influence of the DVR mitigation on DC-link voltage, charging current, voltage and SOC of battery.


  • Investigation of Voltage Sags Effects on ASD and Mitigation Using ESRF Theory-Based DVR

    by Anurag Khergade, Rajshri Satputaley, Siba Kumar Patro

    Voltage sag is a frequently occurring power quality disturbance in the industries equipped with adjustable speed drives (ASD). A detailed investigation of voltage sag effects on ASD performance with the novel mathematical analyses to estimate the ASD parameters during different types of voltage sag is discussed in this article. The effects of voltage sags are mitigated using an enhanced synchronous reference frame (ESRF) theory-based dynamic voltage restorer (DVR). The working principle of the ESRF theory-based DVR during sag is also described. The investigation of the effects of type A, type B and type F voltage sags on ASD parameters are verified using the simulation and the experimental studies. Further, these effects are mitigated by the ESRF theory-based DVR using the developed simulation and experimental models. The ESRF controller of DVR is working effectively during voltage sags by improving its transient response, which tightly regulates the DC-link voltage of ASD around its reference value. Also, the steady-state response of DVR is enhanced during severe voltage sag, which further validates the ability of the ESRF theory-based DVR. This type of improved performance of ASD during voltage sags cannot be obtained using other existing SRF theories of the DVR.


  • Harmonics Reduction of Adjustable Speed Drive Using Transistor Clamped H-Bridge Inverter Based DVR With Enhanced Capacitor Voltage Balancing

    by Anurag Vidyadhar Khergade, R. J. Satputaley, V. B. Borghate, Bvs Raghava

    Harmonics generated by non-linear critical loads are major anxiety for the industries. A control technique for dynamic voltage restorer (DVR) is described to limit voltage harmonics introduced by adjustable speed drive (ASD) in the utility. Moreover, this control technique maintains constant DC-link voltage of ASD during any disturbances occurring at PCC. Mathematical description to limit ASD voltage harmonics and to generate reference DC-link voltage of ASD is illustrated in the dq0 frame. Transistor clamped H-bridge (TCHB) multi-level inverter (MLI) is used as a voltage source inverter of DVR. An enhanced capacitor voltage balancing (ECVB) method for TCHB MLI for the fast dynamic performance of DVR is also discussed. The proposed control technique of DVR to limit ASD voltage harmonics is simulated using MATLAB software. Furthermore, a simulation for DVR protecting ASD during source harmonics, unbalance, sag and swell is carried out and results of ASD performances are demonstrated. The working of the proposed controller of DVR with ECVB strategy based TCHB is reverified using experimental results. ASD voltage harmonics mitigation and fast dynamic response of ECVB based TCHB are the highlights of this article. The performance of the proposed strategy shows satisfactory results with a less complex control system.


  • Analysis of Different Types of Voltage Sag and Its Effects on Adjustable Speed Drive

    by Anurag Khergade, Shivam Garg, R. J. Satputaley, Sanghratna Tembhekar

    Voltage sag continues to be the most common power quality event causing repeated mal-operation of Adjustable Speed Drives (ASD). It either creates speed and torque fluctuations or completely shuts down the operation of ASD. This paper analyze the effects of different types of voltage sag on ASD. The analysis of this phenomenon, including the variation in DC link voltage, input RMS current of ASD, torque and speed of motor due to voltage sag are presented in this paper. A typical ASD with its parameters and different types of voltage sag are also discussed in this paper. To study the performance of the ASD under voltage sag, simulation based study is carried out for symmetrical, unsymmetrical and phase shifted voltage sag and results are presented comparatively. Different voltage sag mitigation techniques for ASD are discussed in brief.


  • Experimental investigation of new three phase five level transistor clamped H-bridge inverter

    by R. J. Satputaley, V. B. Borghate, Vinod Kumar, Trinath Kumar

    This paper presents an experimental investigation of reduced component 3-ɸ, five- level transistor clamped H-bridge (TCHB) voltage source inverter. With reference to review literature, it was found that difficulties were encountered while implementing the developed inverter due the problems in dead band and delay logic. The proposed work in this paper intends to achieve the dead band and delay logic in order to avoid short circuit on DC supply due to simultaneous firing of switches. The inverter is analyzed through MATLAB® SIMULINK software for unity and lagging power factor conditions. The simulation results are verified by means of the practical tests conducted on a laboratory prototype with d-SPACE DS-1103. The performance of inverter is experimentally evaluated for change in the modulation index from 0.5 to 1.2. The importance of deadband and delay logic circuitry for this topology is also explained. THD analysis of output phase voltage and current for the different modulation index is analyzed and realized through experimentation. Finally, comparison of TCHB inverter with classical inverter is given for effectiveness of developed study.


  • Performance analysis of DVR using “new reduced component” multilevel inverter

    by Rajshri J. Satputaley, Vijay B. Borghate

    The use of the dynamic voltage restorer (DVR) is preferred for the mitigation of voltage quality disturbances. In this paper, the real-time application of a 5-level transistor clamped H-bridge inverter for the single-phase DVR to realize the voltage sag mitigation is discussed. The controller is realized by comparing a sensitive load voltage with a reference voltage generated by the unit vector template method. MATLAB Simulink software is used to test the ability of the developed DVR by employing the in-phase and pre-sag compensation techniques. In addition, an experimental evaluation is performed in real time to observe the compensation capability of a 5-level transistor clamped H-bridge DVR. The design details of developed DVR are discussed, a prototype of DVR is also built in the laboratory. For verification of the capability of proposed DVR topology for voltage sag mitigation, experimental findings are presented.