Yongan Kong
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Yongan Kong has a total of 6 co-authors. Here are the top co-authors by number of shared publications:
- Zhenyu Liu
Guangdong University of Technology
2 shared publications - Chengguang Li
School of Information Engineering, Guangdong University of Technology, Guangzhou, China
1 shared publication - Jiayan Wu
The School of Information Engineering Guangdong University of Technology Guangzhou China
1 shared publication - Wei Lu
School of Information Engineering, Guangdong University of Technology, Guangzhou, China
1 shared publication - Xin Zhang
School of Information Engineering, Guangdong University of Technology, 47870 Guangzhou, Guangdong China
1 shared publication - Xin Zhang
School of Information Engineering, Guangdong University of Technology, Guangzhou, China
1 shared publication
Latest Publications
- 6 December 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 71 (00189456) , 1-15
Mutual Interference Suppression Using Signal Separation and Adaptive Mode Decomposition in Noncontact Vital Sign Measurements
Noncontact vital sign measurements based on millimeter-wave radar can realize long-range detection of respiratory and heartbeat signals, therefore it is gradually applied in more and more scenes. With an increase in the number of millimeter-wave radar devices, the mutual interference between radar signals will occur, which will increase the noise floor. Moreover, respiratory and heartbeat signals are relatively weak and easy to be submerged by the high noise floor. To solve this problem, we present a novel method for suppressing mutual interference and extracting vital signs using improved morphological component analysis (IMCA) and an adaptive parameter optimization variational mode decomposition (APVMD) algorithm. The IMCA algorithm is used to suppress the mutual interference based on the different sparsities of components in different sparse domains, and this improvement solves the inability of the MCA algorithm to detect the interfered signal. Then, the APVMD algorithm is used to extract respiratory and heartbeat signals from the signal containing residual noise. The rate of energy loss is used as the index to optimize the parameters, and the step size of the penalty value is adaptively adjusted according to the center frequency of the mode. The simulation and field experiment results show that the proposed method can significantly improve the signal-to-noise ratios (SNRs) of respiratory and heartbeat signals in the case of mutual interference between radar signals. Moreover, a comparison with other interference suppression and extraction methods shows that the proposed method better improves the SNR and accuracy.
- 6 December 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 71 (00189456) , 1-15
Mutual Interference Suppression Using Signal Separation and Adaptive Mode Decomposition in Noncontact Vital Sign Measurements
Noncontact vital sign measurements based on millimeter-wave radar can realize long-range detection of respiratory and heartbeat signals, therefore it is gradually applied in more and more scenes. With an increase in the number of millimeter-wave radar devices, the mutual interference between radar signals will occur, which will increase the noise floor. Moreover, respiratory and heartbeat signals are relatively weak and easy to be submerged by the high noise floor. To solve this problem, we present a novel method for suppressing mutual interference and extracting vital signs using improved morphological component analysis (IMCA) and an adaptive parameter optimization variational mode decomposition (APVMD) algorithm. The IMCA algorithm is used to suppress the mutual interference based on the different sparsities of components in different sparse domains, and this improvement solves the inability of the MCA algorithm to detect the interfered signal. Then, the APVMD algorithm is used to extract respiratory and heartbeat signals from the signal containing residual noise. The rate of energy loss is used as the index to optimize the parameters, and the step size of the penalty value is adaptively adjusted according to the center frequency of the mode. The simulation and field experiment results show that the proposed method can significantly improve the signal-to-noise ratios (SNRs) of respiratory and heartbeat signals in the case of mutual interference between radar signals. Moreover, a comparison with other interference suppression and extraction methods shows that the proposed method better improves the SNR and accuracy.
- 25 September 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Signal Processing Letters
- Vol. 27 (10709908) , 1745-1749
Vital Sign Extraction in the Presence of Radar Mutual Interference
Respiratory and heartbeat signals are faint vital signs that provide diagnostic and prophylactic information for detecting physiological state. With the increasing number of scenes equipped with frequency modulated continuous wave radar, the probability of mutual interference between radars increases. Mutual interference may raise the noise floor level, which easily affects the extraction of respiratory and heartbeat signals. To solve this issue, we propose a method for extracting vital signs. First, we use the improved pruned exact linear time algorithm to determine the position of the interference signal. Then, the interference signal is restored by the autoregressive model. Finally, the residual noise is removed by bandpass filtering and ensemble empirical mode decomposition to obtain vital signs. The experimental results show that the proposed method can significantly improve the signal-to-noise ratio of vital signs and effectively extract vital signs from the interference signal.
- 25 September 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Signal Processing Letters
- Vol. 27 (10709908) , 1745-1749
Vital Sign Extraction in the Presence of Radar Mutual Interference
Respiratory and heartbeat signals are faint vital signs that provide diagnostic and prophylactic information for detecting physiological state. With the increasing number of scenes equipped with frequency modulated continuous wave radar, the probability of mutual interference between radars increases. Mutual interference may raise the noise floor level, which easily affects the extraction of respiratory and heartbeat signals. To solve this issue, we propose a method for extracting vital signs. First, we use the improved pruned exact linear time algorithm to determine the position of the interference signal. Then, the interference signal is restored by the autoregressive model. Finally, the residual noise is removed by bandpass filtering and ensemble empirical mode decomposition to obtain vital signs. The experimental results show that the proposed method can significantly improve the signal-to-noise ratio of vital signs and effectively extract vital signs from the interference signal.