Zihao Yan
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Zihao Yan has a total of 4 co-authors. Here are the top co-authors by number of shared publications:
- Paul B. Shyn
Brigham and Women’s Hospital, Harvard Medical School
1 shared publication - Ramin Khorasani
Brigham and Women’s Hospital, Boston, USA
1 shared publication - Victor H. Gerbaudo
From the Departments of Radiology and Medicine, McMaster University, 1200 Main St W, Room 1P11, Hamilton, ON, Canada L8N 3Z5 (K.A.Z.); and Department of Radiology, Brigham and Women’s Hospital, Harvard Medical School, Boston, Mass (V.H.G.).
1 shared publication - Vincent M. Levesque
Department of Radiology, Brigham and Women’s Hospital, Boston, USA
1 shared publication
Latest Publications
- 11 November 2020
- Published by Springer Nature in European Journal of Nuclear Medicine and Molecular Imaging
- Vol. 48 (5) , 1618-1625
Liver tumor F-18 FDG-PET before and immediately after microwave ablation enables imaging and quantification of tumor tissue contraction
Purpose Poor liver tumor visibility after microwave ablation (MWA) limits direct tumor ablation margin assessments using contrast-enhanced CT or ultrasound (US). Positron emission tomography (PET) or PET/CT may offer improved intraprocedural assessment of liver tumor ablation margins versus current imaging techniques, as 18F-fluorodeoxyglucose (18F-FDG)-avid tumors remain visible on PET immediately following ablation. The purpose of this study was to assess intraprocedural 18F-FDG PET scans before and immediately after PET/CT-guided MWA for visualization and quantification of metabolic liver tumor tissue contraction resulting from MWA. Methods This retrospective study, conducted at a large academic medical center after Institutional Review Board approval, included 36 patients (20 men; mean age 63 [range 37–85]) who underwent PET/CT-guided MWA of 42 18F-FDG-avid liver tumors from May 2013 to March 2018. Tumor metabolic diameters (short/long axes) were measured for each tumor on pre- and post-ablation PET images. Tumor metabolic volumes were calculated using tumor diameter measurements and compared with automated volumes using an SUV threshold algorithm. A two-tailed paired t test was used for the analyses. Results Comparing intraprocedural pre- and post-ablation PET images, mean metabolic tumor short- and long-axis diameters decreased from 21.4 to 14.9 mm [− 29%, p < 0.001, standard deviation (SD) 18%] and from 24.0 to 18.0 mm (− 24%, p < 0.001, SD 16%), respectively. The mean calculated tumor metabolic volume decreased from 10.5 to 4.6 mm3 (− 55%, p < 0.001, SD 26%). The mean automated tumor metabolic volume decreased from 10.6 to 5.8 mm3 (− 45%, p < 0.001, SD 30%). Conclusion Intraprocedural PET images of 18F-FDG-avid liver tumors allow visualization and quantification of MWA-induced metabolic tumor tissue contraction during 18F-FDG PET/CT-guided procedures. The ability to visualize contracted tumor immediately post-MWA may facilitate emerging intraprocedural PET and PET/CT imaging techniques that address a clinical gap in directly assessing the ablation margin.
- 11 November 2020
- Published by Springer Nature in European Journal of Nuclear Medicine and Molecular Imaging
- Vol. 48 (5) , 1618-1625
Liver tumor F-18 FDG-PET before and immediately after microwave ablation enables imaging and quantification of tumor tissue contraction
Purpose Poor liver tumor visibility after microwave ablation (MWA) limits direct tumor ablation margin assessments using contrast-enhanced CT or ultrasound (US). Positron emission tomography (PET) or PET/CT may offer improved intraprocedural assessment of liver tumor ablation margins versus current imaging techniques, as 18F-fluorodeoxyglucose (18F-FDG)-avid tumors remain visible on PET immediately following ablation. The purpose of this study was to assess intraprocedural 18F-FDG PET scans before and immediately after PET/CT-guided MWA for visualization and quantification of metabolic liver tumor tissue contraction resulting from MWA. Methods This retrospective study, conducted at a large academic medical center after Institutional Review Board approval, included 36 patients (20 men; mean age 63 [range 37–85]) who underwent PET/CT-guided MWA of 42 18F-FDG-avid liver tumors from May 2013 to March 2018. Tumor metabolic diameters (short/long axes) were measured for each tumor on pre- and post-ablation PET images. Tumor metabolic volumes were calculated using tumor diameter measurements and compared with automated volumes using an SUV threshold algorithm. A two-tailed paired t test was used for the analyses. Results Comparing intraprocedural pre- and post-ablation PET images, mean metabolic tumor short- and long-axis diameters decreased from 21.4 to 14.9 mm [− 29%, p < 0.001, standard deviation (SD) 18%] and from 24.0 to 18.0 mm (− 24%, p < 0.001, SD 16%), respectively. The mean calculated tumor metabolic volume decreased from 10.5 to 4.6 mm3 (− 55%, p < 0.001, SD 26%). The mean automated tumor metabolic volume decreased from 10.6 to 5.8 mm3 (− 45%, p < 0.001, SD 30%). Conclusion Intraprocedural PET images of 18F-FDG-avid liver tumors allow visualization and quantification of MWA-induced metabolic tumor tissue contraction during 18F-FDG PET/CT-guided procedures. The ability to visualize contracted tumor immediately post-MWA may facilitate emerging intraprocedural PET and PET/CT imaging techniques that address a clinical gap in directly assessing the ablation margin.