Conor G. McCoy
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Conor G. McCoy has a total of 10 co-authors. Here are the top co-authors by number of shared publications:
Stanislav I. Stoliarov
3 shared publications- Stanislav I. Stoliarov
Department of Fire Protection Engineering University of Maryland College Park Maryland USA
2 shared publications Alexandra E. Klieger
Fire Protection Engineering, University of Maryland, 3104E J.M. Patterson Building, College Park, MD 20742, USA
1 shared publicationDennis K. Kim
Fire Protection Engineering, University of Maryland, 3104E J.M. Patterson Building, College Park, MD 20742, USA
1 shared publicationHongyun Hu
1 shared publicationJessica L. Tilles
1 shared publication
Latest Publications
- 22 October 2021
- Published by Wiley in Fire and Materials
- Vol. 46 (6) , 905-918
Prediction of UL‐94V tests performed on a wide range of polymeric materials using a comprehensive pyrolysis model coupled with an empirical flame heat feedback model
- 22 October 2021
- Published by Wiley in Fire and Materials
- Vol. 46 (6) , 905-918
Prediction of UL‐94V tests performed on a wide range of polymeric materials using a comprehensive pyrolysis model coupled with an empirical flame heat feedback model
- 1 March 2021
- Published by Elsevier in Combustion and Flame
- Vol. 225, 214-227
Experimental characterization and modeling of boundary conditions and flame spread dynamics observed in the UL-94V test
- 1 March 2021
- Published by Elsevier in Combustion and Flame
- Vol. 225, 214-227
Experimental characterization and modeling of boundary conditions and flame spread dynamics observed in the UL-94V test
- Open Access
- 15 September 2020
- Published by American Chemical Society (ACS)
Measurement and modeling of the boundary conditions of UL-94V test samples
- 15 September 2020
- Published by American Chemical Society (ACS)
Open AccessMeasurement and modeling of the boundary conditions of UL-94V test samples
- 1 January 2019
- Published by Elsevier in Fire Safety Journal
- Vol. 103, 38-48
Empirical Model of flame heat feedback for simulation of cone calorimetry
- 1 January 2019
- Published by Elsevier in Fire Safety Journal
- Vol. 103, 38-48
Empirical Model of flame heat feedback for simulation of cone calorimetry
- 26 February 2018
- Published by Taylor & Francis in Science and Technology for the Built Environment
- Vol. 24 (8) , 861-866
An improved test method for refrigerant flammability limits in a 12 L vessel
The current study presents an improved test method for refrigerant flammability limit measurements. Such measurements are essential for determining refrigerant safety classifications. Predicated on expert interviews and experiments, several changes to ASTM E681 and related standards are recommended, as follows. The 12 L glass vessel should be replaced with transparent polycarbonate. The orientation of the electrode supports and the temperature probe should be changed from vertical to horizontal. All penetrations should be removed from the rubber stopper, it should be weighted for a total mass of 2.5 kg, and the initial pressure should be 90 kPa absolute. The flame angle should be plotted versus refrigerant concentration to obtain flammability limits. Finally, the vessel pressure should be measured during each test. These changes are relatively easy to implement and they will improve the test precision and reproducibility without significantly changing previously established flammability limits.
- 26 February 2018
- Published by Taylor & Francis in Science and Technology for the Built Environment
- Vol. 24 (8) , 861-866
An improved test method for refrigerant flammability limits in a 12 L vessel
The current study presents an improved test method for refrigerant flammability limit measurements. Such measurements are essential for determining refrigerant safety classifications. Predicated on expert interviews and experiments, several changes to ASTM E681 and related standards are recommended, as follows. The 12 L glass vessel should be replaced with transparent polycarbonate. The orientation of the electrode supports and the temperature probe should be changed from vertical to horizontal. All penetrations should be removed from the rubber stopper, it should be weighted for a total mass of 2.5 kg, and the initial pressure should be 90 kPa absolute. The flame angle should be plotted versus refrigerant concentration to obtain flammability limits. Finally, the vessel pressure should be measured during each test. These changes are relatively easy to implement and they will improve the test precision and reproducibility without significantly changing previously established flammability limits.