    Pulsed field atrial fibrillation ablation with variable loop circular catheter: outcomes from large US registry

    by Fengwei Zou, Justin Song, Karen Lee, Nikil Prasad, Sarah Xu, Ariel Gidon, Shubhi Pandey, Jishu Motta, Lowell Safren, Cristian Zamora Rosales, et al.


  • Open Access

    Artificial intelligence-intracardiac echocardiography-guided pulsed field ablation of atrial fibrillation with variable-loop circular catheter

    by Fengwei Zou, Sarah Xu, Justin Song, Ariel Gidon, Aung Lin, Nikil Prasad, Nils Guttenplan, Nicola Tarantino, Ronghua Yang, Dhanunjaya Lakkireddy, et al.

    Aims: Intracardiac echocardiography (ICE) facilitates left atrial (LA) reconstruction during atrial fibrillation (AF) ablation. The artificial intelligence–based CARTOSOUND FAM (AIFAM) module enables automated three-dimensional LA reconstruction without the need for a dedicated pre-ablation mapping catheter. While this workflow has been described previously in radiofrequency ablation, its application and outcome in pulsed field ablation (PFA) remain limited. The objective of this study is to evaluate the feasibility, safety, and arrhythmia-free outcomes of a no-pre-mapping AIFAM-guided workflow during PFA using the variable-loop circular catheter (VLCC). Methods and results: Patients undergoing PFA AF ablation using VLCC were screened and those using AIFAM-guided ablation without pre-map were included in the analysis. The LA shell was created using the AI-based ICE module from the right atrium without the need for a LA mapping catheter and was used as the only reference shell for PFA energy delivery. Baseline demographics, AF subtype, comorbidities, procedural details, and follow-up outcomes were analysed. Recurrence was assessed using a 60-day blanking period and Kaplan–Meier survival analysis. A total of 412 patients underwent AF ablation using VLCC during the study period. Among them, 210 patients (mean age 68.1 ± 10.2 years; 54.8% male) underwent AIFAM-guided ablation without pre-map and were analysed. Atrial fibrillation subtype was paroxysmal in 52% and non-paroxysmal in 48%. Concomitant AF ablation and left atrial appendage occlusion (LAAO) were performed in 76 patients (36%). The mean CHA2DS2-VASc score was 3.4 ± 1.7, and the mean left ventricular ejection fraction was 56.2 ± 11.1%. All patients underwent pulmonary vein isolation, with additional PF lesions including posterior wall isolation in 87.5% and superior vena cava ablation in 60.5%. Skin-to-skin procedure time and LA dwell time were 78.8 ± 29.1 min and 47.1 ± 18.8 min for ablation alone and 87.3 ± 22.9 min and 54.6 ± 13.0 min for concomitant AF ablation and LAAO. Acute procedural success was achieved in 100% of cases. One acute non-catheter-related vascular complication (0.5%), and no late complications were documented. Among 184 patients with at least one follow-up, freedom from arrhythmia survival after the 60-day blanking was 77.7% in paroxysmal AF and 71.8% in non-paroxysmal AF at 270 days. Conclusion: AIFAM enables safe and reliable LA reconstruction for successful PFA ablation, including concomitant AF ablation and LAAO using VLCC, and reduces the need for pre-ablation mapping in select patients undergoing index ablation. This strategy demonstrated high acute success, low complication rates, and favourable arrhythmia freedom in a contemporary cohort.


  • Open Access

    Pre-clinical impact of higher irrigation flow rates during pulsed field ablation with a variable loop circular catheter

    by Fengwei Zou, Xiao-Dong Zhang, Tara Gomez, Eric Byun, Qi Chen, Jacopo Marazzato, Marco Schiavone, Sanghamitra Mohanty, Vincenzo Mirco La Fazia, Jishu Motta, et al.


  • Open Access

    Safety and Chronic Atrial Lesion Formation With a Large-Tip, Contact-Force-Sensing Multipolar Pulsed Field Ablation Catheter: Effect of Application Number in a Porcine Beating Heart Model

    by Luigi Di Biase, Jacopo Marazzato, Marco Schiavone, Fengwei Zou, Taylor Spangler, Rahul Bhardwaj, Jonathan Hsu, Assaf Govari, Andreas Altman, Kevin Okarski, et al.

    BACKGROUND: Integration of catheter–tissue contact force with pulsed field ablation (PFA) dosing is essential for achieving safe and durable lesion formation with contact force sensing catheters in ventricular models. However, data on the use of these catheters for atrial ablation remain limited. This study evaluated the procedural safety and 30-day lesion characteristics of atrial PFA delivered with the OMNYPULSE ablation catheter in a porcine model. METHODS: Twelve pigs were randomized to receive either 6 (×6 or Group A) or 12 (×12 or group B) PFA applications per ablation. Following 3-dimensional electroanatomic mapping, PFA was delivered to the right superior and inferior pulmonary veins, cavotricuspid isthmus, right atrial posterior wall, left atrial roof, and mitral annulus. Procedural safety was assessed acutely, and lesion characteristics were evaluated on 30-day histology. Maximum transmurality extent (MTE) was defined as >80% of the lesion span exhibiting continuous endocardial-to-epicardial fibrosis within representative histological sections. RESULTS: Adequate catheter–tissue contact was achieved during PFA delivery (contact force, 28±15 g). No acute procedural complications were observed. At 30 days, PVs and right atrial sites (ie, cavotricuspid isthmus and right atrial posterior wall) demonstrated near-complete MTE regardless of PFA dosing. In contrast, MTE was significantly lower at the mitral annulus and LA roof compared with other sites (44±30% and 21±26%, respectively; P <0.001). Increasing the number of PFA applications (×12) resulted in a remarkable improvement in MTE at these locations, with MTE increases of up to 68% compared with ×6 dosing at these sites. CONCLUSIONS: Atrial PFA using the OMNYPULSE catheter was feasible and safe in a porcine model. However, lesion transmurality varied by atrial location and was dose-dependent at select sites, underscoring the need for site-specific PFA dosing strategies. Further studies are warranted to define optimal PFA parameters for consistent atrial lesion formation.


  • Electrogram-guided pulsed field ablation for persistent atrial fibrillation: A prospective cohort study

    by Kaige Li, Luigi Di Biase, Mu Qin, Shaohui Wu, Xiaodong Zhang, Xu Liu, Xumin Hou


  • Open Access

    Atrial fibrillation ablation using three-dimensional artificial intelligence module integration with intracardiac echocardiography

    by Fengwei Zou, Sarah Xu, Sanjana Nagraj, Sheetal Mathai, Ariel Gidon, Nay Yee Wint Kyaw, Jose Matias, Giuseppe Ammirati, Jacopo Marazzato, Aung Lin, et al.

    Aims: Intracardiac echocardiography-based electroanatomical mapping (EAM) improves procedural efficiency and safety in atrial fibrillation (AF) ablation and remains the standard of care. The CARTOSOUND FAM (AI FAM) module uses a deep-learning algorithm that automates left atrial reconstruction without manual contouring. This study aims to evaluate the 1-year outcomes of AI FAM compared to standard-of-care EAM in AF ablation. Methods and results: This study included 298 patients undergoing radiofrequency AF ablation between January 2021 and December 2023. Patients treated before January 2023 underwent standard-of-care EAM, while those in 2023 utilized AI FAM-based reconstruction. Baseline demographics, comorbidities, AF type, and medication use were recorded. Procedural characteristics, acute success, complications, and AF recurrence at 1-year follow-up were analysed. Of the 298 patients, 115 underwent mapping with AI FAM and 183 with EAM. Baseline characteristics were comparable. AI FAM reduced mean total procedure time (122.5 ± 23.5 vs. 129.0 ± 30.4 min, P = 0.040) and left atrial (LA) dwell time (78.3 ± 21.45 vs. 87.5 ± 28.2 min, P = 0.001). Acute procedural success was 98.3% in AI FAM vs. 98.9% in EAM with fewer complications observed in the AI FAM group (1 vs. 4). At 1 year, freedom from AF recurrence was comparable (80.0% AI FAM vs. 81.4% EAM at 1 year, LogRank P = 0.610). Conclusion: AI FAM was associated with incremental but significant procedural advantages over conventional contouring via reduced total procedure time and LA dwell time, without compromising acute and long-term safety and rhythm control efficacy. AI FAM integration with pulsed field ablation will mark another step towards making AF ablation more streamlined and accessible.


  • Open Access

    Procedural characteristics and clinical outcomes from same-day discharge after pulsed field ablation treatment for atrial fibrillation: an admIRE trial sub-analysis

    by Luigi Di Biase, Vivek Y Reddy, Xiaodong Zhang, David Newton, Sandeep Goyal, Devi Nair, William H Sauer, Vivek Iyer, Christopher F Liu, Jose Osorio, et al.

    Aims: Same-day discharge (SDD) following catheter ablation for atrial fibrillation (AF) yields a promising approach to enhance patient satisfaction and reduce healthcare costs. While prior data support the safety of SDD after radiofrequency ablation, evidence following pulsed field ablation (PFA) remains limited. This sub-analysis of the admIRE trial (NCT05293639) evaluates the safety of SDD compared with overnight stays (ONS) after PFA using a variable-loop circular catheter (VLCC). Methods and results: Baseline and procedural characteristics, safety, and effectiveness were compared between SDD and ONS groups. Primary effectiveness was defined as freedom from composite failure using Kaplan–Meier estimates. Serious adverse events (SAEs) occurring ≤7 days and ≥1 day post-index procedure were assessed. Amongst 277 patients in the admIRE trial, 119 (43.0%) completed SDD, and 158 (57.0%) stayed overnight. The SDD group included fewer patients aged ≥65 years (41.2% vs. 52.5%), shorter fluoroscopy times (4.0 vs. 8.9 min), higher first-pass isolation rates (97.5% vs. 82.9%), and fewer procedural AEs (1.7% vs. 3.8%). More procedures in the SDD group occurred in the morning (63.0% vs. 39.2%). Freedom from primary effectiveness failure was similar (SDD, 75.4% [95% CI 67.4–83.3%] vs. ONS, 74.0% [95% CI 66.4–81.5%]). No significant difference in SAE risk was observed overall [HR, 1.07 (95% CI 0.47–2.44)] or ≤7 days post-procedure [HR, 0.78 (95% CI 0.17–3.49)]. Post-procedural serious cardiac/vascular AE rates were also comparable (SDD, 2.5% vs. ONS, 1.3%). Conclusion: SDD is feasible in a paroxysmal AF population undergoing PFA with the VLCC, demonstrating comparable safety and effectiveness outcomes with overnight hospitalization.


  • Open Access

    Application repetition and electrode–tissue contact result in deeper lesions using a pulsed-field ablation circular variable loop catheter

    by Luigi Di Biase, Jacopo Marazzato, Tara Gomez, Eric Byun, Fengwei Zou, Vito Grupposo, Sanghamitra Mohanty, Vincenzo Mirco La Fazia, Giuseppe Ammirati, Aung Lin, et al.

    Pulsed-field ablation (PFA) is a novel, myocardial-selective, non-thermal ablation modality used to target cardiac arrhythmias. Although prompt electrogram (EGM) signal disappearance is observed immediately after PFA application in the pulmonary veins, whether this finding results in adequate transmural lesions is unknown. The aim of this study is to check whether application repetition and catheter–tissue contact impact lesion formation during PFA. A circular loop PFA catheter was used to deliver repeated energy applications with various levels of contact force. A benchtop vegetal potato model and a beating heart ventricular myocardial model were utilized to evaluate the impact of application repetition, contact force, and catheter repositioning on contiguity and lesion depth. Lesion development occurred over 18 h in the vegetal model and over 6 h in the porcine model. Lesion formation was found to be dependent on application repetition and contact. In porcine ventricles, single and multiple stacked applications led to a lesion depth of 3.5 ± 0.7 and 4.4 ± 1.3 mm, respectively (P = 0.002). Furthermore, the greater the catheter–tissue contact, the more contiguous and deeper the lesions in the vegetal model (1.0 ± 0.9 mm with no contact vs. 5.4 ± 1.4 mm with 30 g of force; P = 0.0001). Pulsed-field ablation delivered via a circular catheter showed that both repetition and catheter contact led independently to deeper lesion formation. These findings indicate that endpoints for effective PFA are related more to PFA biophysics than to mere EGM attenuation.


  • Open Access

    Pulsed Field Ablation Index–Guided Ablation for Lesion Formation: Impact of Contact Force and Number of Applications in the Ventricular Model

    by Luigi Di Biase, Jacopo Marazzato, Assaf Govari, Andreas Altman, Christopher Beeckler, Joe Keyes, Tushar Sharma, Vito Grupposo, Fengwei Zou, Masafumi Sugawara, et al.

    BACKGROUND: The effect of contact force (CF) on lesion formation is not clear during pulsed field ablation (PFA). The aim of this study was to evaluate the impact of CF, PFA, and their interplay through the PFA index (PF index) formula on the ventricular lesion size in swine. METHODS: PFA was delivered through the CF-sensing OMNYPULSE catheter. Predefined PFA applications (×3, ×6, ×9, and ×12) were delivered maintaining low (5–25 g), high (26–50 g), and very high (51–80 g) CFs. First, PFA lesions were evaluated on necropsy in 11 swine to investigate the impact of CF/PFA—and their integration in the PF index equation—on lesion size (study characterization). Then, 3 different PF index thresholds—300, 450, and 600—were tested in 6 swine to appraise the PF index accuracy to predict the ventricular lesion depth (study validation). RESULTS: In the study characterization data set, 111 PFA lesions were analyzed. CF was 32±17 g. The average lesion depth and width were 3.5±1.2 and 12.0±3.5 mm, respectively. More than CF and PFA dose alone, it was their combined effect to impact lesion depth through an asymptotically increasing relationship. Likewise, not only was the PF index related to lesion depth in the study validation data set (r 2 =0.66; P <0.001) but it also provided a prediction accuracy of the observed depth of ±2 mm in 69/73 lesions (95%). CONCLUSIONS: CF and PFA applications play a key role in lesion formation during PFA. Further studies are required to evaluate the best PFA ablation settings to achieve transmural lesions.


  • Open Access

    Point-by-Point Pulsed Field Ablation Using a Multimodality Generator and a Contact Force–Sensing Ablation Catheter: Comparison With Radiofrequency Ablation in a Remapped Chronic Swine Heart

    by Luigi Di Biase, Jacopo Marazzato, Fengwei Zou, Aung Lin, Vito Grupposo, Nilarun Chowdhuri, Jennifer Maffre, Salman Farshchi-Heydari, Tushar Sharma, Christopher Beeckler, et al.

    Background: Pulsed field ablation (PFA) has emerged as an alternative to radiofrequency ablation. However, data on focal point-by-point PFA are scarce. The aim of this study was to compare lesion durability and collateral damage between focally delivered unipolar/biphasic PFA versus radiofrequency in swine. Methods: Eighteen swine were randomized to low-dose PFA, high-dose PFA, and radiofrequency using a multimodality generator. Radiofrequency delivered by market-available generator served as control group. A contact force–sensing catheter was used to focally deliver PFA/radiofrequency at the pulmonary veins and other predefined sites in the atria. Animals were remapped postprocedurally and 28 days postablation to test lesion durability followed by gross necroscopy and histology. Results: All targeted sites were successfully ablated (contact force value, 13.9±4.1 g). Follow-up remapping showed persistent pulmonary vein isolation in all animals (100%) with lesion durability at nonpulmonary vein sites proven in most (98%). Regardless of the energy source used, the lesion size was similar across the study groups. Transmurality was achieved in 95% of targeted sites and 100% at pulmonary veins. On histology, PFA animals showed more mature scar formation than their radiofrequency counterpart without myocardial necrosis or inflammation. Finally, no sign of collateral damage was observed in any of the groups. Conclusions: In a randomized preclinical study, focally delivered unipolar/biphasic PFA guided by contact force values was associated with durable lesions on chronic remapping and with mature scar formation on histology without signs of collateral injury on necroscopy. Further studies are needed to investigate the long-term feasibility of this new approach to atrial fibrillation treatment.