Yoshiki Takei
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Yoshiki Takei has a total of 5 co-authors. Here are the top co-authors by number of shared publications:
- Hajime Monzen
Department of Medical Physics, Graduate School of Medical Sciences, Kindai University, Osaka, Japan
1 shared publication - Kenji Matsumoto
Radiology service, Kindai University Hospital
1 shared publication - Kohei Hanaoka
Graduate School of Medical Science, Department of Medical Physics, Kindai University, Osaka, Japan
1 shared publication - Mikoto Tamura
Department of Medical Physics, Graduate School of Medical Sciences, Kindai University , Ohno-Higashi, Osaka-Sayama, Osaka , Japan
1 shared publication - Yasumasa Nishimura
Department of Radiation Oncology, Kindai University Faculty of Medicine, Osaka 589-8511, Japan
1 shared publication
Latest Publications
- Open Access
- 1 July 2019
- Published by Oxford University Press (OUP) in BJR|Open
- Vol. 1 (1)
Registration accuracy with the low dose kilovoltage cone-beam CT: A phantom study
The aim of this study was to investigate low-dose kilovoltage cone-beam CT (kV-CBCT) for image-guided radiotherapy, with a particular focus on the accuracy of image registration with low-dose protocols. Imaging doses were measured with a NOMEX semiconductor detector positioned at the front of head, thorax, and pelvis human body phantoms while kV-CBCT scans were acquired at different tube currents. Aspects of image quality (spatial resolution, noise, uniformity, contrast, geometric distortion, and Hounsfield unit sensitivity) and image registration accuracy using bone and soft tissue were evaluated. With preset and the lowest tube currents, the imaging doses were 0.16 and 0.08 mGy, 5.29 and 2.80 mGy, and 18.23 and 2.69 mGy for head, thorax, and pelvis, respectively. Noise was the only quality aspect directly dependent on tube current, being increased by 1.5 times with a tube current half that of the preset in head and thorax, and by 2.2 times with a tube current 1/8 of the preset in the pelvis. Accurate auto-bone matching was performed within 1 mm at the lowest tube current. The auto-soft tissue matching could not be performed with the lowest tube current; however, manual-soft tissue matching could still be performed within 2 mm or less. Noise was the only image quality aspect dependent on the imaging dose. Auto-bone and manual-soft tissue matching could still be performed at the lowest imaging dose. When optimizing kV-CBCT imaging dose, the impact on bone and soft tissue image registration accuracy should be evaluated.
- 1 July 2019
- Published by Oxford University Press (OUP) in BJR|Open
- Vol. 1 (1)
Open AccessRegistration accuracy with the low dose kilovoltage cone-beam CT: A phantom study
The aim of this study was to investigate low-dose kilovoltage cone-beam CT (kV-CBCT) for image-guided radiotherapy, with a particular focus on the accuracy of image registration with low-dose protocols. Imaging doses were measured with a NOMEX semiconductor detector positioned at the front of head, thorax, and pelvis human body phantoms while kV-CBCT scans were acquired at different tube currents. Aspects of image quality (spatial resolution, noise, uniformity, contrast, geometric distortion, and Hounsfield unit sensitivity) and image registration accuracy using bone and soft tissue were evaluated. With preset and the lowest tube currents, the imaging doses were 0.16 and 0.08 mGy, 5.29 and 2.80 mGy, and 18.23 and 2.69 mGy for head, thorax, and pelvis, respectively. Noise was the only quality aspect directly dependent on tube current, being increased by 1.5 times with a tube current half that of the preset in head and thorax, and by 2.2 times with a tube current 1/8 of the preset in the pelvis. Accurate auto-bone matching was performed within 1 mm at the lowest tube current. The auto-soft tissue matching could not be performed with the lowest tube current; however, manual-soft tissue matching could still be performed within 2 mm or less. Noise was the only image quality aspect dependent on the imaging dose. Auto-bone and manual-soft tissue matching could still be performed at the lowest imaging dose. When optimizing kV-CBCT imaging dose, the impact on bone and soft tissue image registration accuracy should be evaluated.