Dan Gnansia
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Dan Gnansia has a total of 63 co-authors. Here are the top co-authors by number of shared publications:
- Michel Hoen
Clinical Evidence Department, Oticon Medical, 06220 Vallauris, France
5 shared publications - Ana Cláudia Mirândola Barbosa Reis
Universidade de São Paulo, Brasil
2 shared publications - Chadlia Karoui
Clinical Evidence Department, Oticon Medical, 2720 Chem de Saint-Bernard, 06220 Vallauris, France
2 shared publications - Clair Vandersteen
Université Côte d'Azur, laboratoire CoBTeK, Nice, France; Institut Universitaire de la Face et du Cou, UR2CA-REBOOT, 31 Avenue de Valombrose, 06100, Centre Hospitalier Universitaire, Université Côte d'Azur, Nice, Alpes-Maritimes, France
2 shared publications - Eduardo Tanaka Massuda
Universidade de São Paulo, Brasil
2 shared publications - Eric Truy
Hôpital Edouard Herriot, Service ORL, Place d'Arsonval, 69003 Lyon, France
2 shared publications
Latest Publications
- Open Access
- 9 November 2022
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 11 (22) , 6640
A Web-Based Automated Image Processing Research Platform for Cochlear Implantation-Related Studies
The robust delineation of the cochlea and its inner structures combined with the detection of the electrode of a cochlear implant within these structures is essential for envisaging a safer, more individualized, routine image-guided cochlear implant therapy. We present Nautilus—a web-based research platform for automated pre- and post-implantation cochlear analysis. Nautilus delineates cochlear structures from pre-operative clinical CT images by combining deep learning and Bayesian inference approaches. It enables the extraction of electrode locations from a post-operative CT image using convolutional neural networks and geometrical inference. By fusing pre- and post-operative images, Nautilus is able to provide a set of personalized pre- and post-operative metrics that can serve the exploration of clinically relevant questions in cochlear implantation therapy. In addition, Nautilus embeds a self-assessment module providing a confidence rating on the outputs of its pipeline. We present a detailed accuracy and robustness analyses of the tool on a carefully designed dataset. The results of these analyses provide legitimate grounds for envisaging the implementation of image-guided cochlear implant practices into routine clinical workflows.
- 9 November 2022
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 11 (22) , 6640
Open AccessA Web-Based Automated Image Processing Research Platform for Cochlear Implantation-Related Studies
The robust delineation of the cochlea and its inner structures combined with the detection of the electrode of a cochlear implant within these structures is essential for envisaging a safer, more individualized, routine image-guided cochlear implant therapy. We present Nautilus—a web-based research platform for automated pre- and post-implantation cochlear analysis. Nautilus delineates cochlear structures from pre-operative clinical CT images by combining deep learning and Bayesian inference approaches. It enables the extraction of electrode locations from a post-operative CT image using convolutional neural networks and geometrical inference. By fusing pre- and post-operative images, Nautilus is able to provide a set of personalized pre- and post-operative metrics that can serve the exploration of clinically relevant questions in cochlear implantation therapy. In addition, Nautilus embeds a self-assessment module providing a confidence rating on the outputs of its pipeline. We present a detailed accuracy and robustness analyses of the tool on a carefully designed dataset. The results of these analyses provide legitimate grounds for envisaging the implementation of image-guided cochlear implant practices into routine clinical workflows.
- 1 November 2022
- Published by Elsevier in Brazilian Journal of Otorhinolaryngology (Versão em Português)
- Vol. 88, S108-S117
Implicações clínicas do eABR intraoperatório para usuários do feixe de eletrodos Evo
- 1 November 2022
- Published by Elsevier in Brazilian Journal of Otorhinolaryngology (Versão em Português)
- Vol. 88, S108-S117
Implicações clínicas do eABR intraoperatório para usuários do feixe de eletrodos Evo
- Open Access
- 1 November 2022
- Published by Elsevier in Brazilian Journal of Otorhinolaryngology
- Vol. 88 (Suppl 1) , S108-S117
Clinical implications of intraoperative eABRs to the Evo®-CI electrode array recipients
- 1 November 2022
- Published by Elsevier in Brazilian Journal of Otorhinolaryngology
- Vol. 88 (Suppl 1) , S108-S117
Open AccessClinical implications of intraoperative eABRs to the Evo®-CI electrode array recipients
- Open Access
- 31 October 2022
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 17 (10) , e0275961
Current distribution of distributed all-polar cochlear implant stimulation mode measured in-situ
Oticon Medical cochlear implants use a stimulation mode called Distributed All-Polar (DAP) that connects all non-stimulating available intracochlear electrodes and an extracochlear reference electrode. It results in a complex distribution of current that is yet undescribed. The present study aims at providing a first characterization of this current distribution. A Neuro Zti was modified to allow the measurement of current returning to each electrode during a DAP stimulation and was implanted in an ex-vivo human head. Maps of distributed current were then created for different stimulation conditions with different charge levels. Results show that, on average, about 20% of current returns to the extracochlear reference electrode, while the remaining 80% is distributed between intracochlear electrodes. The position of the stimulating electrode changed this ratio, and about 10% more current to the extracochlear return in case of the first 3 basal electrodes than for apical and mid position electrodes was observed. Increasing the charge level led to small but significant change in the ratio, and about 4% more current to the extracochlear return was measured when increasing the charge level from 11.7 to 70 nC. Further research is needed to show if DAP yields better speech understanding than other stimulation modes.
- 31 October 2022
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 17 (10) , e0275961
Open AccessCurrent distribution of distributed all-polar cochlear implant stimulation mode measured in-situ
Oticon Medical cochlear implants use a stimulation mode called Distributed All-Polar (DAP) that connects all non-stimulating available intracochlear electrodes and an extracochlear reference electrode. It results in a complex distribution of current that is yet undescribed. The present study aims at providing a first characterization of this current distribution. A Neuro Zti was modified to allow the measurement of current returning to each electrode during a DAP stimulation and was implanted in an ex-vivo human head. Maps of distributed current were then created for different stimulation conditions with different charge levels. Results show that, on average, about 20% of current returns to the extracochlear reference electrode, while the remaining 80% is distributed between intracochlear electrodes. The position of the stimulating electrode changed this ratio, and about 10% more current to the extracochlear return in case of the first 3 basal electrodes than for apical and mid position electrodes was observed. Increasing the charge level led to small but significant change in the ratio, and about 4% more current to the extracochlear return was measured when increasing the charge level from 11.7 to 70 nC. Further research is needed to show if DAP yields better speech understanding than other stimulation modes.
- Open Access
- 31 January 2022
- Published by MDPI AG in Brain Sciences
- Vol. 12 (2) , 205
Increased Threshold and Reduced Firing Rate of Auditory Cortex Neurons after Cochlear Implant Insertion
The cochlear implant (CI) is the most successful neuroprosthesis allowing thousands of patients with profound hearing loss to recover speech understanding. Recently, cochlear implants have been proposed to subjects with residual hearing and, in these cases, shorter CIs were implanted. To be successful, it is crucial to preserve the patient’s remaining hearing abilities after the implantation. Here, we quantified the effects of CI insertion on the responses of auditory cortex neurons in anesthetized guinea pigs. The responses of auditory cortex neurons were determined before and after the insertion of a 300 µm diameter CI (six stimulating electrodes, length 6 mm). Immediately after CI insertion there was a 5 to 15 dB increase in the threshold for cortical neurons from the middle to the high frequencies, accompanied by a decrease in the evoked firing rate. Analyzing the characteristic frequency (CF) values revealed that in large number of cases, the CFs obtained after insertion were lower than before. These effects were not detected in the control animals. These results indicate that there is a small but immediate cortical hearing loss after CI insertion, even with short length CIs. Therefore, efforts should be made to minimize the damages during CI insertion to preserve the cortical responses to acoustic stimuli.
- 31 January 2022
- Published by MDPI AG in Brain Sciences
- Vol. 12 (2) , 205
Open AccessIncreased Threshold and Reduced Firing Rate of Auditory Cortex Neurons after Cochlear Implant Insertion
The cochlear implant (CI) is the most successful neuroprosthesis allowing thousands of patients with profound hearing loss to recover speech understanding. Recently, cochlear implants have been proposed to subjects with residual hearing and, in these cases, shorter CIs were implanted. To be successful, it is crucial to preserve the patient’s remaining hearing abilities after the implantation. Here, we quantified the effects of CI insertion on the responses of auditory cortex neurons in anesthetized guinea pigs. The responses of auditory cortex neurons were determined before and after the insertion of a 300 µm diameter CI (six stimulating electrodes, length 6 mm). Immediately after CI insertion there was a 5 to 15 dB increase in the threshold for cortical neurons from the middle to the high frequencies, accompanied by a decrease in the evoked firing rate. Analyzing the characteristic frequency (CF) values revealed that in large number of cases, the CFs obtained after insertion were lower than before. These effects were not detected in the control animals. These results indicate that there is a small but immediate cortical hearing loss after CI insertion, even with short length CIs. Therefore, efforts should be made to minimize the damages during CI insertion to preserve the cortical responses to acoustic stimuli.
- Open Access
- 29 November 2021
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 10 (23) , 5604
One Year Assessment of the Hearing Preservation Potential of the EVO Electrode Array
Background: A prospective longitudinal multicentre study was conducted to assess the one-year postsurgical hearing preservation profile of the EVOTM electrode array. Methods: Fifteen adults presenting indications of electro-acoustic stimulation (pure-tone audiometry (PTA) thresholds ≤70 dB below 750 Hz) were implanted with the EVO™ electrode array. Hearing thresholds were collected at five time-points from CI activation to twelve months (12M) after activation. Hearing thresholds and hearing preservation profiles (HEARRING group classification) were assessed. Results: All subjects had measurable hearing thresholds at follow-up. No case of complete loss of hearing or minimal hearing preservation was reported at any time point. At activation (Nact = 15), five participants had complete hearing preservation, and ten participants had partial hearing preservation. At the 12M time point (N12m = 6), three participants had complete hearing preservation, and three participants had partial hearing preservation. Mean hearing loss at activation was 11 dB for full range PTA and 25 dB for PTAs low-frequency (125–500 Hz). Conclusions: This study provides the first longitudinal follow-up on associated hearing profiles to the EVO™ electrode array, which are comparable to the literature. However, other studies on larger populations should be performed.
- 29 November 2021
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 10 (23) , 5604
Open AccessOne Year Assessment of the Hearing Preservation Potential of the EVO Electrode Array
Background: A prospective longitudinal multicentre study was conducted to assess the one-year postsurgical hearing preservation profile of the EVOTM electrode array. Methods: Fifteen adults presenting indications of electro-acoustic stimulation (pure-tone audiometry (PTA) thresholds ≤70 dB below 750 Hz) were implanted with the EVO™ electrode array. Hearing thresholds were collected at five time-points from CI activation to twelve months (12M) after activation. Hearing thresholds and hearing preservation profiles (HEARRING group classification) were assessed. Results: All subjects had measurable hearing thresholds at follow-up. No case of complete loss of hearing or minimal hearing preservation was reported at any time point. At activation (Nact = 15), five participants had complete hearing preservation, and ten participants had partial hearing preservation. At the 12M time point (N12m = 6), three participants had complete hearing preservation, and three participants had partial hearing preservation. Mean hearing loss at activation was 11 dB for full range PTA and 25 dB for PTAs low-frequency (125–500 Hz). Conclusions: This study provides the first longitudinal follow-up on associated hearing profiles to the EVO™ electrode array, which are comparable to the literature. However, other studies on larger populations should be performed.
- Open Access
- 1 September 2020
- Published by Taylor & Francis in Expert Review of Medical Devices
- Vol. 17 (9) , 959-967
Clinical efficiency and safety of the oticon medical neuro cochlear implant system: a multicenter prospective longitudinal study
This prospective longitudinal cohort study at six tertiary referral centers in Canada and Denmark describes the clinical efficiency and surgical safety of cochlear implantation with the Oticon Medi...
- 1 September 2020
- Published by Taylor & Francis in Expert Review of Medical Devices
- Vol. 17 (9) , 959-967
Open AccessClinical efficiency and safety of the oticon medical neuro cochlear implant system: a multicenter prospective longitudinal study
This prospective longitudinal cohort study at six tertiary referral centers in Canada and Denmark describes the clinical efficiency and surgical safety of cochlear implantation with the Oticon Medi...
- 1 June 2016
- Published by Elsevier in European Annals of Otorhinolaryngology, Head and Neck Diseases
- Vol. 133, S66-S67
Optimal electrode diameter in relation to volume of the cochlea
- 1 June 2016
- Published by Elsevier in European Annals of Otorhinolaryngology, Head and Neck Diseases
- Vol. 133, S66-S67
Optimal electrode diameter in relation to volume of the cochlea
- Open Access
- 1 June 2015
- Published by MDPI AG in Audiology Research
- Vol. 5 (2) , 139
One-Year Follow up of Auditory Performance in Post-Lingually Deafened Adults Implanted with the Neurelec Digisonic® Sp/saphyr® Neo Cochlear Implant System
This study aimed to quantify outcomes in a group of patients who were implanted with an Oticon Medical Neurelec (Vallauris, France) cochlear implant system, the Digisonic® SP/Saphyr® Neo. Ten participants took part in this preliminary study. Their speech perception capacities were evaluated at 3, 6, and 12-months after cochlear implant activation and compared to pre-implantation scores and to scores observed with former versions of the sound processor. Compared to former versions of the sound processor, patients using the Saphyr® Neo processor obtained better speech perception scores for sentences in silence at each tests session (3 months: 79%, 6 months: 82% and 12 months: 94%) compared to Digisonic® users (respectively: 58%, 69% and 75%) and Convex sound processor users (resp. 39%, 59% and 51%). These observations confirm that the technological improvements made in the Saphyr® Neo sound processor coupled with the Digisonic® implant, provided quantifiable benefits in speech perception in Quiet compared to former versions of the processor Convex and Digisonic® SP.
- 1 June 2015
- Published by MDPI AG in Audiology Research
- Vol. 5 (2) , 139
Open AccessOne-Year Follow up of Auditory Performance in Post-Lingually Deafened Adults Implanted with the Neurelec Digisonic® Sp/saphyr® Neo Cochlear Implant System
This study aimed to quantify outcomes in a group of patients who were implanted with an Oticon Medical Neurelec (Vallauris, France) cochlear implant system, the Digisonic® SP/Saphyr® Neo. Ten participants took part in this preliminary study. Their speech perception capacities were evaluated at 3, 6, and 12-months after cochlear implant activation and compared to pre-implantation scores and to scores observed with former versions of the sound processor. Compared to former versions of the sound processor, patients using the Saphyr® Neo processor obtained better speech perception scores for sentences in silence at each tests session (3 months: 79%, 6 months: 82% and 12 months: 94%) compared to Digisonic® users (respectively: 58%, 69% and 75%) and Convex sound processor users (resp. 39%, 59% and 51%). These observations confirm that the technological improvements made in the Saphyr® Neo sound processor coupled with the Digisonic® implant, provided quantifiable benefits in speech perception in Quiet compared to former versions of the processor Convex and Digisonic® SP.
- 1 June 2013
- Published by Taylor & Francis in Cochlear Implants International
- Vol. 14 (3) , 150-157
Combined electric and acoustic hearing performance with Zebra®speech processor: Speech reception, place, and temporal coding evaluation
To assess the auditory performance of Digisonic(®) cochlear implant users with electric stimulation (ES) and electro-acoustic stimulation (EAS) with special attention to the processing of low-frequency temporal fine structure. Six patients implanted with a Digisonic(®) SP implant and showing low-frequency residual hearing were fitted with the Zebra(®) speech processor providing both electric and acoustic stimulation. Assessment consisted of monosyllabic speech identification tests in quiet and in noise at different presentation levels, and a pitch discrimination task using harmonic and disharmonic intonating complex sounds ( Vaerenberg et al., 2011 ). These tests investigate place and time coding through pitch discrimination. All tasks were performed with ES only and with EAS. Speech results in noise showed significant improvement with EAS when compared to ES. Whereas EAS did not yield better results in the harmonic intonation test, the improvements in the disharmonic intonation test were remarkable, suggesting better coding of pitch cues requiring phase locking. These results suggest that patients with residual hearing in the low-frequency range still have good phase-locking capacities, allowing them to process fine temporal information. ES relies mainly on place coding but provides poor low-frequency temporal coding, whereas EAS also provides temporal coding in the low-frequency range. Patients with residual phase-locking capacities can make use of these cues.
- 1 June 2013
- Published by Taylor & Francis in Cochlear Implants International
- Vol. 14 (3) , 150-157
Combined electric and acoustic hearing performance with Zebra®speech processor: Speech reception, place, and temporal coding evaluation
To assess the auditory performance of Digisonic(®) cochlear implant users with electric stimulation (ES) and electro-acoustic stimulation (EAS) with special attention to the processing of low-frequency temporal fine structure. Six patients implanted with a Digisonic(®) SP implant and showing low-frequency residual hearing were fitted with the Zebra(®) speech processor providing both electric and acoustic stimulation. Assessment consisted of monosyllabic speech identification tests in quiet and in noise at different presentation levels, and a pitch discrimination task using harmonic and disharmonic intonating complex sounds ( Vaerenberg et al., 2011 ). These tests investigate place and time coding through pitch discrimination. All tasks were performed with ES only and with EAS. Speech results in noise showed significant improvement with EAS when compared to ES. Whereas EAS did not yield better results in the harmonic intonation test, the improvements in the disharmonic intonation test were remarkable, suggesting better coding of pitch cues requiring phase locking. These results suggest that patients with residual hearing in the low-frequency range still have good phase-locking capacities, allowing them to process fine temporal information. ES relies mainly on place coding but provides poor low-frequency temporal coding, whereas EAS also provides temporal coding in the low-frequency range. Patients with residual phase-locking capacities can make use of these cues.