Matej Valič
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Matej Valič has a total of 14 co-authors. Here are the top co-authors by number of shared publications:
- Janez Mohar
Department of Spine Surgery, Valdoltra Orthopedic Hospital, Ankaran, Slovenia
3 shared publications - Rene Mihalič
Valdoltra Orthopaedic Hospital, Ankaran, Slovenia
3 shared publications - Eva Podovšovnik
Orthopedic Hospital of Valdoltra, Jadranska Cesta 31, 6280 Ankaran, Slovenia
2 shared publications - Vesna Levašič
National Arthroplasty Registry of Slovenia, Valdoltra Orthopaedic Hospital, 6280 Ankaran, Slovenia
2 shared publications - David Žižek
Faculty of Medicine, University of Ljubljana , Vrazov trg 2, 1000 Ljubljana
1 shared publication - Denia Savarin
Valdoltra Orthopaedic Hospital, Ankaran, Slovenia
1 shared publication
Latest Publications
- Open Access
- 22 August 2025
- Published by Slovenian Medical Association in Slovenian Medical Journal
- p. 1-7
Vpliv hrbtenično-medeničnih razmerij na uspešnost ledveno-križnične zatrditve in totalne kolčne artroplastike
Medenični obroč povezuje kot tečaj ledveno-križnično hrbtenico in kolke ter z ohranjanjem ledvene lordoze in ekstenzije v kolkih omogoča energetsko učinkovito stoječo držo. Razumevanje medsebojnega vpliva med hrbtenico in medenico je ključnega pomena pri načrtovanju in izvedbi totalne artroplastike kolka in/ali fiksacije ledveno-križnične hrbtenice. Z večanjem rigidnosti ledvene hrbtenice zmanjšujemo gibljivost hrbtenično-medeničnega kompleksa in povečujemo tveganje za utesnitev in izpah kolčne totalne endoproteze. Vpadni kot medenice je statični parameter, značilen za vsakega posameznika in klinično določa medsebojne vplive med hrbtenico in medenico. Primerjava drugih parametrov med stoječim in sedečim položajem omogoča oceno medenične gibljivosti v sagitalni ravnini. Sagitalna klasifikacija celotnega hrbteničnega stebra pri stoji in morfologija medenice pa določata obseg gibanja kolkov. Osebe z ožjo, bolj navpično medenico in nizkim vpadnim kotom ter naklonom križnice imajo omejeno medenično retroverzijo in hrbtenično-medenično gibljivost. To pa zahteva večjo gibljivost kolkov. Nasprotno pa imajo osebe s širšo in bolj vodoravno medenico ter višjim vpadnim kotom in naklonom križnice večjo sagitalno hrbtenično-medenično gibljivost. Zato potrebujejo prvi več anteverzije acetabularne komponente, drugi pa manj. Dobro gibljiva ledvena hrbtenica varuje kolčni sklep, medtem ko zahteva togi ledveno-križnični segment večjo kolčno gibljivost, kar lahko ogroža uspešnost totalne kolčne endoproteze. Čeprav enotnega soglasja še ni, pa se večina nedavnih smernic strinja, da je pri bolnikih z visokim tveganjem za izpah po totalni kolčni artroplastiki smiselno opraviti pred operacijo stranske rentgenske posnetke hrbtenično-medeničnega kompleksa stojé in sede. Tako lahko optimiziramo položaj acetabularne komponente pri nenormalni hrbtenično-medenični poravnavi ali gibljivosti ter zmanjšamo tveganje za izpah. V primeru, da je potrebna operacija tako kolčnega sklepa kot ledveno-križničnega prehoda, je priporočljivo najprej opraviti totalno kolčno artroplastiko. Izjema je prisotnost kompenzacijske retroverzije medenice, ko je za postavitev medenice v bolj fiziološko anteverzijo priporočljivo najprej operirati ledveno-križnično hrbtenico.
- 22 August 2025
- Published by Slovenian Medical Association in Slovenian Medical Journal
- p. 1-7
Open AccessVpliv hrbtenično-medeničnih razmerij na uspešnost ledveno-križnične zatrditve in totalne kolčne artroplastike
Medenični obroč povezuje kot tečaj ledveno-križnično hrbtenico in kolke ter z ohranjanjem ledvene lordoze in ekstenzije v kolkih omogoča energetsko učinkovito stoječo držo. Razumevanje medsebojnega vpliva med hrbtenico in medenico je ključnega pomena pri načrtovanju in izvedbi totalne artroplastike kolka in/ali fiksacije ledveno-križnične hrbtenice. Z večanjem rigidnosti ledvene hrbtenice zmanjšujemo gibljivost hrbtenično-medeničnega kompleksa in povečujemo tveganje za utesnitev in izpah kolčne totalne endoproteze. Vpadni kot medenice je statični parameter, značilen za vsakega posameznika in klinično določa medsebojne vplive med hrbtenico in medenico. Primerjava drugih parametrov med stoječim in sedečim položajem omogoča oceno medenične gibljivosti v sagitalni ravnini. Sagitalna klasifikacija celotnega hrbteničnega stebra pri stoji in morfologija medenice pa določata obseg gibanja kolkov. Osebe z ožjo, bolj navpično medenico in nizkim vpadnim kotom ter naklonom križnice imajo omejeno medenično retroverzijo in hrbtenično-medenično gibljivost. To pa zahteva večjo gibljivost kolkov. Nasprotno pa imajo osebe s širšo in bolj vodoravno medenico ter višjim vpadnim kotom in naklonom križnice večjo sagitalno hrbtenično-medenično gibljivost. Zato potrebujejo prvi več anteverzije acetabularne komponente, drugi pa manj. Dobro gibljiva ledvena hrbtenica varuje kolčni sklep, medtem ko zahteva togi ledveno-križnični segment večjo kolčno gibljivost, kar lahko ogroža uspešnost totalne kolčne endoproteze. Čeprav enotnega soglasja še ni, pa se večina nedavnih smernic strinja, da je pri bolnikih z visokim tveganjem za izpah po totalni kolčni artroplastiki smiselno opraviti pred operacijo stranske rentgenske posnetke hrbtenično-medeničnega kompleksa stojé in sede. Tako lahko optimiziramo položaj acetabularne komponente pri nenormalni hrbtenično-medenični poravnavi ali gibljivosti ter zmanjšamo tveganje za izpah. V primeru, da je potrebna operacija tako kolčnega sklepa kot ledveno-križničnega prehoda, je priporočljivo najprej opraviti totalno kolčno artroplastiko. Izjema je prisotnost kompenzacijske retroverzije medenice, ko je za postavitev medenice v bolj fiziološko anteverzijo priporočljivo najprej operirati ledveno-križnično hrbtenico.
- Open Access
Linear and Volumetric Polyethylene Wear Patterns after Primary Cruciate-Retaining Total Knee Arthroplasty Failure: An Analysis Using Optical Scanning and Computer-Aided Design Models
(1) Background: Analyses of retrieved inserts allow for a better understanding of TKA failure mechanisms and the detection of factors that cause increased wear. The purpose of this implant retrieval study was to identify whether insert volumetric wear significantly differs among groups of common causes of total knee arthroplasty failure, whether there is a characteristic wear distribution pattern for a common cause of failure, and whether nominal insert size and component size ratio (femur-to-insert) influence linear and volumetric wear rates. (2) Methods: We digitally reconstructed 59 retrieved single-model cruciate-retaining inserts and computed their articular load-bearing surface wear utilizing an optical scanner and computer-aided design models as references. After comprehensively reviewing all cases, each was categorized into one or more of the following groups: prosthetic joint infection, osteolysis, clinical loosening of the component, joint malalignment or component malposition, instability, and other isolated causes. The associations between volumetric wear and causes of failure were estimated using a multiple linear regression model adjusted for time in situ. Insert linear penetration wear maps from the respective groups of failure were further processed and merged to create a single average binary image, highlighting a potential wear distribution pattern. The differences in wear rates according to nominal insert size (small vs. medium vs. large) and component size ratio (≤1 vs. >1) were tested using the Kruskal–Wallis test and the Mann–Whitney test, respectively. (3) Results: Patients with identified osteolysis alone and those also with clinical loosening of the component had significantly higher volumetric wear when compared to those without both causes (p = 0.016 and p = 0.009, respectively). All other causes were not significantly associated with volumetric wear. The instability group differentiated from the others with a combined peripheral antero-posterior wear distribution. Linear and volumetric wear rates showed no significant differences when compared by nominal insert size (small vs. medium vs. large, p = 0.563 and p = 0.747, respectively) or by component (femoral-to-insert) size ratio (≤1 vs. >1, p = 0.885 and p = 0.055, respectively). (4) Conclusions: The study found increased volumetric wear in cases of osteolysis alone, with greater wear when combined with clinical loosening compared to other groups. The instability group demonstrated a characteristic peripheral anterior and posterior wear pattern. Insert size and component size ratio seem not to influence wear rates.
Open AccessLinear and Volumetric Polyethylene Wear Patterns after Primary Cruciate-Retaining Total Knee Arthroplasty Failure: An Analysis Using Optical Scanning and Computer-Aided Design Models
(1) Background: Analyses of retrieved inserts allow for a better understanding of TKA failure mechanisms and the detection of factors that cause increased wear. The purpose of this implant retrieval study was to identify whether insert volumetric wear significantly differs among groups of common causes of total knee arthroplasty failure, whether there is a characteristic wear distribution pattern for a common cause of failure, and whether nominal insert size and component size ratio (femur-to-insert) influence linear and volumetric wear rates. (2) Methods: We digitally reconstructed 59 retrieved single-model cruciate-retaining inserts and computed their articular load-bearing surface wear utilizing an optical scanner and computer-aided design models as references. After comprehensively reviewing all cases, each was categorized into one or more of the following groups: prosthetic joint infection, osteolysis, clinical loosening of the component, joint malalignment or component malposition, instability, and other isolated causes. The associations between volumetric wear and causes of failure were estimated using a multiple linear regression model adjusted for time in situ. Insert linear penetration wear maps from the respective groups of failure were further processed and merged to create a single average binary image, highlighting a potential wear distribution pattern. The differences in wear rates according to nominal insert size (small vs. medium vs. large) and component size ratio (≤1 vs. >1) were tested using the Kruskal–Wallis test and the Mann–Whitney test, respectively. (3) Results: Patients with identified osteolysis alone and those also with clinical loosening of the component had significantly higher volumetric wear when compared to those without both causes (p = 0.016 and p = 0.009, respectively). All other causes were not significantly associated with volumetric wear. The instability group differentiated from the others with a combined peripheral antero-posterior wear distribution. Linear and volumetric wear rates showed no significant differences when compared by nominal insert size (small vs. medium vs. large, p = 0.563 and p = 0.747, respectively) or by component (femoral-to-insert) size ratio (≤1 vs. >1, p = 0.885 and p = 0.055, respectively). (4) Conclusions: The study found increased volumetric wear in cases of osteolysis alone, with greater wear when combined with clinical loosening compared to other groups. The instability group demonstrated a characteristic peripheral anterior and posterior wear pattern. Insert size and component size ratio seem not to influence wear rates.
- 29 October 2022
- Published by Springer Nature in European Spine Journal
- Vol. 31 (12) , 3544-3550
Pedicle screw placement safety with the aid of patient-specific guides in a case series of patients with thoracic scoliosis
Purpose Pedicle screw (PS) placement in thoracic scoliotic deformities can be challenging due to altered vertebral anatomy; malposition can result in severe functional disability or inferior construct stability. Three-dimensional (3D) printed patient-specific guides (PSGs) have been recently used to supplement other PS placement techniques. We conducted a single-center, retrospective observational study to assess the accuracy of PS placement using PSGs in a consecutive case series of pediatric and adult patients with thoracic scoliosis. Methods We analyzed the data of patients with thoracic scoliosis who underwent PS placement using 3D-printed PSG as a vertebral cannulation aid between June 2013 and July 2018. PS positions were determined via Gertzbein–Robbins (GR) and Heary classifications on computed tomography images. We determined the concordance of actual and preoperatively planned PS positions and defined the technique learning curve using a receiver-operating characteristic (ROC) curve. Results We performed 362 thoracic PS placement procedures in 39 consecutive patients. We classified 352 (97.2%), 2 (0.6%), and 8 (2.2%) screws as GR grades 0 (optimal placement), I, and II, respectively. The average instrumented PS entry point offsets on the X- and Y-axes were both 0.8 mm, and the average differences in trajectory between the planned and the actual screw placements on the oblique sagittal and oblique transverse planes were 2.0° and 2.4°, respectively. The learning process was ongoing until the first 12 PSs were placed. Conclusions The accuracy of PS placement using patient-specific 3D templates in our case series exceeds the accuracies of established thoracic PS placement techniques.
- 29 October 2022
- Published by Springer Nature in European Spine Journal
- Vol. 31 (12) , 3544-3550
Pedicle screw placement safety with the aid of patient-specific guides in a case series of patients with thoracic scoliosis
Purpose Pedicle screw (PS) placement in thoracic scoliotic deformities can be challenging due to altered vertebral anatomy; malposition can result in severe functional disability or inferior construct stability. Three-dimensional (3D) printed patient-specific guides (PSGs) have been recently used to supplement other PS placement techniques. We conducted a single-center, retrospective observational study to assess the accuracy of PS placement using PSGs in a consecutive case series of pediatric and adult patients with thoracic scoliosis. Methods We analyzed the data of patients with thoracic scoliosis who underwent PS placement using 3D-printed PSG as a vertebral cannulation aid between June 2013 and July 2018. PS positions were determined via Gertzbein–Robbins (GR) and Heary classifications on computed tomography images. We determined the concordance of actual and preoperatively planned PS positions and defined the technique learning curve using a receiver-operating characteristic (ROC) curve. Results We performed 362 thoracic PS placement procedures in 39 consecutive patients. We classified 352 (97.2%), 2 (0.6%), and 8 (2.2%) screws as GR grades 0 (optimal placement), I, and II, respectively. The average instrumented PS entry point offsets on the X- and Y-axes were both 0.8 mm, and the average differences in trajectory between the planned and the actual screw placements on the oblique sagittal and oblique transverse planes were 2.0° and 2.4°, respectively. The learning process was ongoing until the first 12 PSs were placed. Conclusions The accuracy of PS placement using patient-specific 3D templates in our case series exceeds the accuracies of established thoracic PS placement techniques.
- 19 November 2020
- Published by SAGE Publications in HIP International
- Vol. 32 (1) , 32-38
Survival rate of total hip replacements with matched and with mixed components with 10.7 years mean follow-up
Mixing and matching components from different manufacturers in total hip arthroplasty is a frequently used off-label praxis. The clinical consequences of this procedure have not been studied in detail. 860 patients with matched and 1067 patients with mixed primary total hip replacement (THR) components carried out between 1 January 2002 and 31 December 2004, were selected from our Institution registry. The analysis endpoint was set at 1 January 2016. THRs with poorly performing components were excluded from study groups. Kaplan-Meier survival curves for both groups were calculated and compared using the Log-Rank test and the demographic data using the chi-square test. Correlations between demographic data and revisions were calculated using bivariate correlation. 28 revisions were carried out in the matched group and 67 in the mixed group. The 14-year overall survival probability was significantly better in the former (96.0%) than in the mixed group (92.7%) (p = 0.002). Survival, free of aseptic and septic failures, was statistically, significantly higher in the matched group (p = 0.026 and p = 0.007, respectively). The survival of the mixed subgroup with heads and stems from the same manufacturer did not differ statistically from that of the matched group (p = 0.079). In contrast to the results listed in the National Joint Registry and the New Zealand Joint Registry, the survival probability in our study was, statistically, significantly higher in total hip replacements using components of the same manufacturer. Importantly, mixing and matching the components of different manufacturers led to similar survival providing the head and the stem were from the same manufacturer.
- 19 November 2020
- Published by SAGE Publications in HIP International
- Vol. 32 (1) , 32-38
Survival rate of total hip replacements with matched and with mixed components with 10.7 years mean follow-up
Mixing and matching components from different manufacturers in total hip arthroplasty is a frequently used off-label praxis. The clinical consequences of this procedure have not been studied in detail. 860 patients with matched and 1067 patients with mixed primary total hip replacement (THR) components carried out between 1 January 2002 and 31 December 2004, were selected from our Institution registry. The analysis endpoint was set at 1 January 2016. THRs with poorly performing components were excluded from study groups. Kaplan-Meier survival curves for both groups were calculated and compared using the Log-Rank test and the demographic data using the chi-square test. Correlations between demographic data and revisions were calculated using bivariate correlation. 28 revisions were carried out in the matched group and 67 in the mixed group. The 14-year overall survival probability was significantly better in the former (96.0%) than in the mixed group (92.7%) (p = 0.002). Survival, free of aseptic and septic failures, was statistically, significantly higher in the matched group (p = 0.026 and p = 0.007, respectively). The survival of the mixed subgroup with heads and stems from the same manufacturer did not differ statistically from that of the matched group (p = 0.079). In contrast to the results listed in the National Joint Registry and the New Zealand Joint Registry, the survival probability in our study was, statistically, significantly higher in total hip replacements using components of the same manufacturer. Importantly, mixing and matching the components of different manufacturers led to similar survival providing the head and the stem were from the same manufacturer.
- 13 March 2020
- Published by Springer Nature in Spine Deformity
- Vol. 8 (4) , 809-817
Malpositioned pedicle screw in spine deformity surgery endangering the aorta: report of two cases, review of literature, and proposed management algorithm
Study design Case reports and review of the literature with a proposed management algorithm. Objectives To report two cases of a potential vascular complication due to an incorrectly placed pedicle screw (PS) during spine deformity surgery. Relevant literature regarding the management of vascular complications is reviewed, and an evidence-based management algorithm is proposed. Summary of background data Aortic lesions represent a rare but potentially life-threatening complications with spine deformity and revision surgery, significantly increasing the risk. A management algorithm for an aortic lesion in the case of a malpositioned PS has not yet been published. Methods Case 1: An 18-year-old female with proximal thoracic spinal non-instrumented fusion underwent a revision corrective procedure due to a progressive right-sided thoracolumbar compensatory curve. However, postoperative computed tomography (CT) performed to evaluate the position of the PS revealed malposition of the left T9 PS, which was abutting the descending aorta with CT angiography excluding the perforation of the aorta. Case 2: A 17-year-old male was scheduled for correction of Lenke 3-C-N adolescent idiopathic scoliosis. Postoperative routine evaluation with low-dose CT revealed a left T9 PS paravertebral malposition, and subsequent CTA demonstrated that the thread of the PS was in contact with the descending thoracic aorta and an unlikely hemodynamically significant vessel injury. Results Successful removal of both malpositioned PS was performed. In the first case, a cardiovascular surgeon attended the operation if an urgent thoracotomy was needed, and in the second case, additional video-assisted thoracoscopic control of the aorta was performed during PS removal. Conclusions Preoperative imaging in spinal surgery is essential to avoid major vascular and other complications when placing PS, especially in thoracic deformities. When a potential major vessel complication emerges, an interdisciplinary approach and an appropriate management algorithm are mandatory to make the best clinical decisions. Level of evidence 4.
- 13 March 2020
- Published by Springer Nature in Spine Deformity
- Vol. 8 (4) , 809-817
Malpositioned pedicle screw in spine deformity surgery endangering the aorta: report of two cases, review of literature, and proposed management algorithm
Study design Case reports and review of the literature with a proposed management algorithm. Objectives To report two cases of a potential vascular complication due to an incorrectly placed pedicle screw (PS) during spine deformity surgery. Relevant literature regarding the management of vascular complications is reviewed, and an evidence-based management algorithm is proposed. Summary of background data Aortic lesions represent a rare but potentially life-threatening complications with spine deformity and revision surgery, significantly increasing the risk. A management algorithm for an aortic lesion in the case of a malpositioned PS has not yet been published. Methods Case 1: An 18-year-old female with proximal thoracic spinal non-instrumented fusion underwent a revision corrective procedure due to a progressive right-sided thoracolumbar compensatory curve. However, postoperative computed tomography (CT) performed to evaluate the position of the PS revealed malposition of the left T9 PS, which was abutting the descending aorta with CT angiography excluding the perforation of the aorta. Case 2: A 17-year-old male was scheduled for correction of Lenke 3-C-N adolescent idiopathic scoliosis. Postoperative routine evaluation with low-dose CT revealed a left T9 PS paravertebral malposition, and subsequent CTA demonstrated that the thread of the PS was in contact with the descending thoracic aorta and an unlikely hemodynamically significant vessel injury. Results Successful removal of both malpositioned PS was performed. In the first case, a cardiovascular surgeon attended the operation if an urgent thoracotomy was needed, and in the second case, additional video-assisted thoracoscopic control of the aorta was performed during PS removal. Conclusions Preoperative imaging in spinal surgery is essential to avoid major vascular and other complications when placing PS, especially in thoracic deformities. When a potential major vessel complication emerges, an interdisciplinary approach and an appropriate management algorithm are mandatory to make the best clinical decisions. Level of evidence 4.