Malpositioned pedicle screw in spine deformity surgery endangering the aorta: report of two cases, review of literature, and proposed management algorithm
- 13 March 2020
- journal article
- review article
- Published by Springer Nature in Spine Deformity
- Vol. 8 (4) , 809-817
Abstract
Study design Case reports and review of the literature with a proposed management algorithm. Objectives To report two cases of a potential vascular complication due to an incorrectly placed pedicle screw (PS) during spine deformity surgery. Relevant literature regarding the management of vascular complications is reviewed, and an evidence-based management algorithm is proposed. Summary of background data Aortic lesions represent a rare but potentially life-threatening complications with spine deformity and revision surgery, significantly increasing the risk. A management algorithm for an aortic lesion in the case of a malpositioned PS has not yet been published. Methods Case 1: An 18-year-old female with proximal thoracic spinal non-instrumented fusion underwent a revision corrective procedure due to a progressive right-sided thoracolumbar compensatory curve. However, postoperative computed tomography (CT) performed to evaluate the position of the PS revealed malposition of the left T9 PS, which was abutting the descending aorta with CT angiography excluding the perforation of the aorta. Case 2: A 17-year-old male was scheduled for correction of Lenke 3-C-N adolescent idiopathic scoliosis. Postoperative routine evaluation with low-dose CT revealed a left T9 PS paravertebral malposition, and subsequent CTA demonstrated that the thread of the PS was in contact with the descending thoracic aorta and an unlikely hemodynamically significant vessel injury. Results Successful removal of both malpositioned PS was performed. In the first case, a cardiovascular surgeon attended the operation if an urgent thoracotomy was needed, and in the second case, additional video-assisted thoracoscopic control of the aorta was performed during PS removal. Conclusions Preoperative imaging in spinal surgery is essential to avoid major vascular and other complications when placing PS, especially in thoracic deformities. When a potential major vessel complication emerges, an interdisciplinary approach and an appropriate management algorithm are mandatory to make the best clinical decisions. Level of evidence 4.Keywords
This publication has 53 references indexed in Scilit:
- Complications of Pedicle Screw Fixation in Scoliosis SurgerySpine, 2010
- New parameters to represent the position of the aorta relative to the spine for pedicle screw placementEuropean Spine Journal, 2010
- Accuracy of free-hand placement of thoracic pedicle screws in adolescent idiopathic scoliosis: how much of a difference does surgeon experience make?European Spine Journal, 2009
- Evaluation of thoracic pedicle screw placement in adolescent idiopathic scoliosisEuropean Spine Journal, 2009
- Benefit and accuracy of intraoperative 3D-imaging after pedicle screw placement: a prospective study in stabilizing thoracolumbar fracturesEuropean Spine Journal, 2009
- Delayed perforation of the aorta by a thoracic pedicle screwEuropean Spine Journal, 2008
- Rationale Behind the Current State-of-the-Art Treatment of Scoliosis (in the Pedicle Screw Era)Spine, 2008
- Placement of pedicle screws in thoracic idiopathic scoliosis: a magnetic resonance imaging analysis of screw placement relative to structures at riskEuropean Spine Journal, 2008
- Observer reliability in evaluating pedicle screw placement using computed tomographyInternational Orthopaedics, 2006
- Volumetric Spinal Canal IntrusionSpine, 2004