Kodai Fukuda
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Kodai Fukuda has a total of 34 co-authors. Here are the top co-authors by number of shared publications:
- Akira Ikoma
Department of Radiology, Wakayama Medical University, Wakayama, Japan
6 shared publications Nobuyuki Higashino
Department of Radiology, Wakayama Medical University, Wakayama, Japan
4 shared publications- Nobuyuki Higashino
Department of Radiology, Wakayama Medical University, Wakayamashi, Japan
4 shared publications - Nobuyuki Kawai
Department of Radiology, Wakayama Medical University, Wakayamashi, Japan
4 shared publications Tetsuo Sonomura
Department of Radiology, Wakayama Medical University, Wakayama, Japan
4 shared publications- Tetsuo Sonomura
Department of Radiology, Wakayama Medical University, Wakayamashi, Japan
4 shared publications
Latest Publications
- Open Access
- 18 January 2026
- Published by Elsevier in Radiology Case Reports
- Vol. 21 (4) , 1478-1481
Successful bronchial artery embolization for racemose hemangioma of the right bronchial artery with pulmonary artery dilatation: A case report
- 18 January 2026
- Published by Elsevier in Radiology Case Reports
- Vol. 21 (4) , 1478-1481
Open AccessSuccessful bronchial artery embolization for racemose hemangioma of the right bronchial artery with pulmonary artery dilatation: A case report
- Open Access
- 6 August 2025
- Published by Elsevier in Radiology Case Reports
- Vol. 20 (11) , 5387-5390
Identification of the right adrenal vein opening using intraoperative 4D-CT angiography from the right adrenal artery in adrenal vein sampling: A case report
- 6 August 2025
- Published by Elsevier in Radiology Case Reports
- Vol. 20 (11) , 5387-5390
Open AccessIdentification of the right adrenal vein opening using intraoperative 4D-CT angiography from the right adrenal artery in adrenal vein sampling: A case report
- 9 June 2025
- Published by Springer Nature in CardioVascular and Interventional Radiology
- Vol. 48 (8) , 1174-1187
Factors that Enhance the Stability of Polidocanol and Monoethanolamine Oleic Acid Foams, and Identification of the Optimal Foam-Creating Device
Purpose To investigate the effects of the air ratio and the addition of glucose solution (Gluc) on the stability of polidocanol-nonionic water-soluble contrast medium (Po/CM) and monoethanolamine oleate-nonionic water-soluble contrast medium (EO/CM) foams, and to identify the optimal device to prepare these foams. Materials and Methods Four sclerosants were used: Po/CM (Po:CM = 1:1), Po/CM-Gluc (Po:CM:70% Gluc = 2:1:1), EO/CM (EO:CM = 1:1), and EO/CM-Gluc (EO:CM:70% Gluc = 2:1:1). The four sclerosants were mixed with air at ratios of 1:4, 1:7, and 1:10 using the Micro Magic connector (MM), hydrophobic emulsifying connector (Hbic), and hydrophilic emulsifying connector (Hlic). The times taken to prepare the foams using each device and the foam half-lives were measured. Results The Po/CM (1:10) and Po/CM-Gluc (1:10) foams could not be prepared using any device. The EO/CM-Gluc (1:10), Po/CM (1:7), and Po/CM-Gluc (1:7) foams could not be prepared using the MM. The times taken to prepare the foams were not significantly different between the Hbic and Hlic for EO/CM-Gluc (1:4) and Po/CM (1:4). The times taken to prepare the other foams decreased significantly in the order MM > Hbic > Hlic. The half-lives of the foams were significantly prolonged by increasing the air ratio. For foams with the same air ratio, the presence of Gluc significantly increased the half-lives of EO/CM and Po/CM compared with the foams without Gluc. Conclusion The half-lives of foams were prolonged by increasing their air ratio and by adding Gluc. Of the tested mixture devices, Hlic created foams with longer half-lives in the shortest time. Graphical abstract
- 9 June 2025
- Published by Springer Nature in CardioVascular and Interventional Radiology
- Vol. 48 (8) , 1174-1187
Factors that Enhance the Stability of Polidocanol and Monoethanolamine Oleic Acid Foams, and Identification of the Optimal Foam-Creating Device
Purpose To investigate the effects of the air ratio and the addition of glucose solution (Gluc) on the stability of polidocanol-nonionic water-soluble contrast medium (Po/CM) and monoethanolamine oleate-nonionic water-soluble contrast medium (EO/CM) foams, and to identify the optimal device to prepare these foams. Materials and Methods Four sclerosants were used: Po/CM (Po:CM = 1:1), Po/CM-Gluc (Po:CM:70% Gluc = 2:1:1), EO/CM (EO:CM = 1:1), and EO/CM-Gluc (EO:CM:70% Gluc = 2:1:1). The four sclerosants were mixed with air at ratios of 1:4, 1:7, and 1:10 using the Micro Magic connector (MM), hydrophobic emulsifying connector (Hbic), and hydrophilic emulsifying connector (Hlic). The times taken to prepare the foams using each device and the foam half-lives were measured. Results The Po/CM (1:10) and Po/CM-Gluc (1:10) foams could not be prepared using any device. The EO/CM-Gluc (1:10), Po/CM (1:7), and Po/CM-Gluc (1:7) foams could not be prepared using the MM. The times taken to prepare the foams were not significantly different between the Hbic and Hlic for EO/CM-Gluc (1:4) and Po/CM (1:4). The times taken to prepare the other foams decreased significantly in the order MM > Hbic > Hlic. The half-lives of the foams were significantly prolonged by increasing the air ratio. For foams with the same air ratio, the presence of Gluc significantly increased the half-lives of EO/CM and Po/CM compared with the foams without Gluc. Conclusion The half-lives of foams were prolonged by increasing their air ratio and by adding Gluc. Of the tested mixture devices, Hlic created foams with longer half-lives in the shortest time. Graphical abstract
- Open Access
- 31 July 2024
- Published by Elsevier in Radiology Case Reports
- Vol. 19 (10) , 4435-4439
An anomalous left adrenal vein draining into both the left renal vein and inferior vena cava: A case report
- 31 July 2024
- Published by Elsevier in Radiology Case Reports
- Vol. 19 (10) , 4435-4439
Open AccessAn anomalous left adrenal vein draining into both the left renal vein and inferior vena cava: A case report
- 24 October 2023
- Published by Springer Nature in CardioVascular and Interventional Radiology
- Vol. 47 (2) , 268-270
Balloon-Assisted Arterial Embolization of Pseudoaneurysms Using NBCA–Lipiodol–Iopamidol Mixture in Two Clinical Cases
- 24 October 2023
- Published by Springer Nature in CardioVascular and Interventional Radiology
- Vol. 47 (2) , 268-270
Balloon-Assisted Arterial Embolization of Pseudoaneurysms Using NBCA–Lipiodol–Iopamidol Mixture in Two Clinical Cases
- Open Access
- 22 July 2023
- Published by Elsevier in Radiology Case Reports
- Vol. 18 (10) , 3395-3399
Duodenal bleeding outside covered stents identified by selective computed tomography during arteriography that was successfully treated by embolization: A case report
- 22 July 2023
- Published by Elsevier in Radiology Case Reports
- Vol. 18 (10) , 3395-3399
Open AccessDuodenal bleeding outside covered stents identified by selective computed tomography during arteriography that was successfully treated by embolization: A case report
- 21 January 2022
- Published by Springer Nature in CardioVascular and Interventional Radiology
- Vol. 45 (3) , 357-364
Determination of the Optimal Ratio and the Relationship Between Viscosity and Adhesion of n-Butyl Cyanoacrylate–Lipiodol–Iopamidol for Balloon-Assisted Embolization of Wide-Neck Aneurysms in Swine
Purpose To determine the optimal ratio of n-butyl cyanoacrylate–Lipiodol–iopamidol (NLI) for balloon-assisted embolization of wide-neck aneurysms in swine. Materials and Methods Sixteen NLI mixtures were prepared for in vitro studies. The viscosity of each mixture was measured for 30 min. We evaluated whether the mixtures could be injected through a microcatheter and whether they adhered to the microcatheter. In vivo, 15 wide-neck aneurysms were created on the arteries in 4 female swine. Under balloon occlusion, 7 aneurysms were embolized with NLI141 (NBCA:Lipidol:iopamidol = 1:4:1) and 8 were embolized with NLI231. We performed angiography to evaluate adhesion of NLI to the balloons or microcatheters and NLI migration. Results In vitro, the iopamidol content needed to comprise at least 1/6 of the mixture in order for NLI to be non-adhesive with increased viscosity. NLI could not be injected through a microcatheter if the iopamidol content exceeded 1/6 of the mixture. Only NLI141 and NLI231 did not adhere to the microcatheter with increased viscosity, and could be injected through a microcatheter. In vivo, neither NLI mixture adhered to the balloons or microcatheters. The migration of NLI was observed in 6 of 7 aneurysms embolized with NLI141 and in none of 8 aneurysms embolized with NLI231. Conclusion Our in vitro study revealed that the ratios of NLI that were non-adhesive and could be injected through a microcatheter were 1:4:1 and 2:3:1. The optimal ratio of NLI for balloon-assisted embolization of wide-neck aneurysms in swine was considered to be 2:3:1.
- 21 January 2022
- Published by Springer Nature in CardioVascular and Interventional Radiology
- Vol. 45 (3) , 357-364
Determination of the Optimal Ratio and the Relationship Between Viscosity and Adhesion of n-Butyl Cyanoacrylate–Lipiodol–Iopamidol for Balloon-Assisted Embolization of Wide-Neck Aneurysms in Swine
Purpose To determine the optimal ratio of n-butyl cyanoacrylate–Lipiodol–iopamidol (NLI) for balloon-assisted embolization of wide-neck aneurysms in swine. Materials and Methods Sixteen NLI mixtures were prepared for in vitro studies. The viscosity of each mixture was measured for 30 min. We evaluated whether the mixtures could be injected through a microcatheter and whether they adhered to the microcatheter. In vivo, 15 wide-neck aneurysms were created on the arteries in 4 female swine. Under balloon occlusion, 7 aneurysms were embolized with NLI141 (NBCA:Lipidol:iopamidol = 1:4:1) and 8 were embolized with NLI231. We performed angiography to evaluate adhesion of NLI to the balloons or microcatheters and NLI migration. Results In vitro, the iopamidol content needed to comprise at least 1/6 of the mixture in order for NLI to be non-adhesive with increased viscosity. NLI could not be injected through a microcatheter if the iopamidol content exceeded 1/6 of the mixture. Only NLI141 and NLI231 did not adhere to the microcatheter with increased viscosity, and could be injected through a microcatheter. In vivo, neither NLI mixture adhered to the balloons or microcatheters. The migration of NLI was observed in 6 of 7 aneurysms embolized with NLI141 and in none of 8 aneurysms embolized with NLI231. Conclusion Our in vitro study revealed that the ratios of NLI that were non-adhesive and could be injected through a microcatheter were 1:4:1 and 2:3:1. The optimal ratio of NLI for balloon-assisted embolization of wide-neck aneurysms in swine was considered to be 2:3:1.
- 23 November 2020
- Published by Springer Nature in CardioVascular and Interventional Radiology
- Vol. 44 (3) , 482-488
Feasibility and Safety of n-Butyl Cyanoacrylate–Lipiodol–Iopamidol as an Alternative Liquid Embolic Material
Purpose To evaluate the feasibility and safety of n-butyl cyanoacrylate (NBCA)–Lipiodol–Iopamidol (NLI) as a liquid embolic material. Materials and Methods In vitro, the ratio of NLI components was adjusted and the configuration of the mixtures was assessed visually in saline. In vivo, 14 wide-necked aneurysms were created on the common carotid and external iliac arteries of four female swine. Under balloon occlusion, 12 aneurysms were embolized with NLI prepared at a NBCA–Lipidol–Iopamidol ratio of 2:3:1 (NLI231), and two were embolized with NBCA–Lipiodol (NL) prepared at a NBCA–Lipiodol ratio of 1:2 (NL12) as a trial group. We performed angiography to evaluate the effectiveness of embolization and adhesion of the embolic material to the balloons or microcatheters. Results In vitro, NLI231 (33% NBCA) was considered to be the optimal ratio for aneurysm embolization based on its configuration and stability. In vivo, embolization using NLI231 was successful and no adhesion between the embolic material and the balloons or microcatheters was observed in all 12 aneurysms. Embolization with NL12 was impossible in the other two aneurysms due to leakage and adhesion of NL. Conclusion The configuration of NLI changed at each ratio. NLI231 is a feasible and safe liquid embolic material for balloon-assisted embolization of wide-necked aneurysms in swine.
- 23 November 2020
- Published by Springer Nature in CardioVascular and Interventional Radiology
- Vol. 44 (3) , 482-488
Feasibility and Safety of n-Butyl Cyanoacrylate–Lipiodol–Iopamidol as an Alternative Liquid Embolic Material
Purpose To evaluate the feasibility and safety of n-butyl cyanoacrylate (NBCA)–Lipiodol–Iopamidol (NLI) as a liquid embolic material. Materials and Methods In vitro, the ratio of NLI components was adjusted and the configuration of the mixtures was assessed visually in saline. In vivo, 14 wide-necked aneurysms were created on the common carotid and external iliac arteries of four female swine. Under balloon occlusion, 12 aneurysms were embolized with NLI prepared at a NBCA–Lipidol–Iopamidol ratio of 2:3:1 (NLI231), and two were embolized with NBCA–Lipiodol (NL) prepared at a NBCA–Lipiodol ratio of 1:2 (NL12) as a trial group. We performed angiography to evaluate the effectiveness of embolization and adhesion of the embolic material to the balloons or microcatheters. Results In vitro, NLI231 (33% NBCA) was considered to be the optimal ratio for aneurysm embolization based on its configuration and stability. In vivo, embolization using NLI231 was successful and no adhesion between the embolic material and the balloons or microcatheters was observed in all 12 aneurysms. Embolization with NL12 was impossible in the other two aneurysms due to leakage and adhesion of NL. Conclusion The configuration of NLI changed at each ratio. NLI231 is a feasible and safe liquid embolic material for balloon-assisted embolization of wide-necked aneurysms in swine.