Jacob Trueb
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Jacob Trueb has a total of 132 co-authors. Here are the top co-authors by number of shared publications:
- John Allen Rogers
Querrey Simpson Institute for Bioelectronics, Northwestern University, Evanston, IL, 60208, USA
6 shared publications - Kyeongha Kwon
School of Electrical Engineering, Korea Advanced Institute of Science and Technology, Daejeon, Republic of Korea
3 shared publications - Abraham Vázquez-Guardado
Department of Electrical and Computer Engineering North Carolina State University Raleigh North Carolina USA
2 shared publications - Andreas Tzavelis
Querrey Simpson Institute for Bioelectronics, Northwestern University, Evanston, USA
2 shared publications - Anthony Banks
Querrey Simpson Institute for Bioelectronics, Northwestern University, Evanston, IL, 60208, USA; Neurolux Inc., Northfield, IL, 60093, USA; Center for Bio-Integrated Electronics, Northwestern University, Evanston, IL, 60208, USA
2 shared publications Changsheng Wu
Department of Materials Science and Engineering, McCormick School of Engineering, Northwestern University, Evanston, USA
2 shared publications
Latest Publications
- Open Access
- 23 August 2026
- Published by Wiley in Advanced Healthcare Materials
- Vol. 15 (35) , e71623
Multiwavelength Implantable Oximeter for Wireless Monitoring of Tissue Oxygenation in the Presence of Blood Volume Changes
Real‐time continuous measurement of tissue oxygenation (StO 2 ) can provide insight into organ transplant health and disease progression and provide feedback after medical interventions. However, existing optical oximetry approaches typically assume stable blood volume, limiting their usefulness in real‐world scenarios involving vasoconstriction, vasodilation, or acute blood loss. Here, we leverage miniaturized optical sensors and Bluetooth microprocessors to create a fully implantable oximeter that measures subdermal tissue oxygenation and accounts for varying levels of blood volume. The device utilizes a wireless radiofrequency (RF) power transfer scheme that allows high bandwidth Bluetooth data transmission from three wavelength channels: green (537 nm), red (660 nm), and near‐infrared (NIR) (880 nm). Results show that the addition of a green wavelength improves tissue oxygenation estimation in the presence of varying blood volumes. In silico and in vivo validation of the device and tissue oxygenation algorithm is performed in rats during hypoxia, hypercapnia, and occlusion on a variety of tissues such as paw, subdermal muscle, and kidney. Miniaturized, wireless, battery‐free, implantable devices such as these that support mechanisms to compensate for varying blood volumes for StO 2 calculations offer the potential for continuous, real‐time, physiologically consistent monitoring of blood hemodynamics under dynamic physiological conditions.
- 23 August 2026
- Published by Wiley in Advanced Healthcare Materials
- Vol. 15 (35) , e71623
Open AccessMultiwavelength Implantable Oximeter for Wireless Monitoring of Tissue Oxygenation in the Presence of Blood Volume Changes
Real‐time continuous measurement of tissue oxygenation (StO 2 ) can provide insight into organ transplant health and disease progression and provide feedback after medical interventions. However, existing optical oximetry approaches typically assume stable blood volume, limiting their usefulness in real‐world scenarios involving vasoconstriction, vasodilation, or acute blood loss. Here, we leverage miniaturized optical sensors and Bluetooth microprocessors to create a fully implantable oximeter that measures subdermal tissue oxygenation and accounts for varying levels of blood volume. The device utilizes a wireless radiofrequency (RF) power transfer scheme that allows high bandwidth Bluetooth data transmission from three wavelength channels: green (537 nm), red (660 nm), and near‐infrared (NIR) (880 nm). Results show that the addition of a green wavelength improves tissue oxygenation estimation in the presence of varying blood volumes. In silico and in vivo validation of the device and tissue oxygenation algorithm is performed in rats during hypoxia, hypercapnia, and occlusion on a variety of tissues such as paw, subdermal muscle, and kidney. Miniaturized, wireless, battery‐free, implantable devices such as these that support mechanisms to compensate for varying blood volumes for StO 2 calculations offer the potential for continuous, real‐time, physiologically consistent monitoring of blood hemodynamics under dynamic physiological conditions.
- Open Access
- 15 May 2026
- Published by American Association for the Advancement of Science (AAAS) in Science Advances
- Vol. 12 (20) , eaed3162
Wireless, skin-interfaced multimodal sensing system for continuous psychophysiological monitoring—A wearable polygraph device
Accurate, continuous monitoring of psychophysiological states is central to understanding stress and autonomic dysfunction across diverse medical contexts. Current approaches such as polygraphy and polysomnography rely on cumbersome, wired sensors that limit real-world utility and burden patients, particularly vulnerable populations such as infants. Here, we introduce a wireless, skin-interfaced multimodal sensing system capable of simultaneously recording cardiac, respiratory, electrodermal, and thermal signals in a time-synchronized manner. Leveraging compact and soft designs, the technology enables unobtrusive monitoring across controlled, clinical, and naturalistic settings. Validation studies performed in parallel with gold standard systems demonstrate high fidelity in quantifying stress responses during polygraph interviews, cognitive load tasks, and cold pressor tests. In pediatric sleep studies, the data reliably identify arousals, hypopnea, and apnea while revealing disease-specific autonomic signatures in infants with Down syndrome. Real-world deployment during emergency simulation training shows that multimodal stress signatures correlate inversely with performance, underscoring translational value in medical education. Machine learning analyses across all studies confirm that multimodal features outperform single-signal approaches in detecting stress and clinical events with high sensitivity and specificity. Collectively, these findings establish the technology as a next-generation wearable platform that bridges engineering innovation and clinical practice, offering mechanistic insight and diagnostic potential in stress medicine, sleep medicine, and beyond.
- 15 May 2026
- Published by American Association for the Advancement of Science (AAAS) in Science Advances
- Vol. 12 (20) , eaed3162
Open AccessWireless, skin-interfaced multimodal sensing system for continuous psychophysiological monitoring—A wearable polygraph device
Accurate, continuous monitoring of psychophysiological states is central to understanding stress and autonomic dysfunction across diverse medical contexts. Current approaches such as polygraphy and polysomnography rely on cumbersome, wired sensors that limit real-world utility and burden patients, particularly vulnerable populations such as infants. Here, we introduce a wireless, skin-interfaced multimodal sensing system capable of simultaneously recording cardiac, respiratory, electrodermal, and thermal signals in a time-synchronized manner. Leveraging compact and soft designs, the technology enables unobtrusive monitoring across controlled, clinical, and naturalistic settings. Validation studies performed in parallel with gold standard systems demonstrate high fidelity in quantifying stress responses during polygraph interviews, cognitive load tasks, and cold pressor tests. In pediatric sleep studies, the data reliably identify arousals, hypopnea, and apnea while revealing disease-specific autonomic signatures in infants with Down syndrome. Real-world deployment during emergency simulation training shows that multimodal stress signatures correlate inversely with performance, underscoring translational value in medical education. Machine learning analyses across all studies confirm that multimodal features outperform single-signal approaches in detecting stress and clinical events with high sensitivity and specificity. Collectively, these findings establish the technology as a next-generation wearable platform that bridges engineering innovation and clinical practice, offering mechanistic insight and diagnostic potential in stress medicine, sleep medicine, and beyond.
- Open Access
- 25 October 2024
- Published by American Association for the Advancement of Science (AAAS) in Science Advances
- Vol. 10 (43) , eadr3567
An autonomous implantable device for the prevention of death from opioid overdose
Opioid overdose accounts for nearly 75,000 deaths per year in the United States, now a leading cause of mortality among young people aged 18 to 45 years. At overdose levels, opioid-induced respiratory depression becomes fatal without the administration of naloxone within minutes. Currently, overdose survival relies on bystander intervention, requiring a nearby person to find the overdosed individual and have immediate access to naloxone to administer. To circumvent the bystander requirement, we developed the Naloximeter: a class of life-saving implantable devices that autonomously detect and treat overdose while simultaneously contacting first responders. We present three Naloximeter platforms, for fundamental research and clinical translation, all equipped with optical sensors, drug delivery mechanisms, and a supporting ecosystem of technology to counteract opioid-induced respiratory depression. In small and large animal studies, the Naloximeter rescues from otherwise fatal opioid overdose within minutes. This work introduces life-changing, clinically translatable technologies that can broadly benefit a susceptible population recovering from opioid use disorder.
- 25 October 2024
- Published by American Association for the Advancement of Science (AAAS) in Science Advances
- Vol. 10 (43) , eadr3567
Open AccessAn autonomous implantable device for the prevention of death from opioid overdose
Opioid overdose accounts for nearly 75,000 deaths per year in the United States, now a leading cause of mortality among young people aged 18 to 45 years. At overdose levels, opioid-induced respiratory depression becomes fatal without the administration of naloxone within minutes. Currently, overdose survival relies on bystander intervention, requiring a nearby person to find the overdosed individual and have immediate access to naloxone to administer. To circumvent the bystander requirement, we developed the Naloximeter: a class of life-saving implantable devices that autonomously detect and treat overdose while simultaneously contacting first responders. We present three Naloximeter platforms, for fundamental research and clinical translation, all equipped with optical sensors, drug delivery mechanisms, and a supporting ecosystem of technology to counteract opioid-induced respiratory depression. In small and large animal studies, the Naloximeter rescues from otherwise fatal opioid overdose within minutes. This work introduces life-changing, clinically translatable technologies that can broadly benefit a susceptible population recovering from opioid use disorder.
- Top Cited Papers
- 16 November 2023
- Published by Springer Nature in Nature Medicine
- Vol. 29 (12) , 3137-3148
Wireless broadband acousto-mechanical sensing system for continuous physiological monitoring
The human body generates various forms of subtle, broadband acousto-mechanical signals that contain information on cardiorespiratory and gastrointestinal health with potential application for continuous physiological monitoring. Existing device options, ranging from digital stethoscopes to inertial measurement units, offer useful capabilities but have disadvantages such as restricted measurement locations that prevent continuous, longitudinal tracking and that constrain their use to controlled environments. Here we present a wireless, broadband acousto-mechanical sensing network that circumvents these limitations and provides information on processes including slow movements within the body, digestive activity, respiratory sounds and cardiac cycles, all with clinical grade accuracy and independent of artifacts from ambient sounds. This system can also perform spatiotemporal mapping of the dynamics of gastrointestinal processes and airflow into and out of the lungs. To demonstrate the capabilities of this system we used it to monitor constrained respiratory airflow and intestinal motility in neonates in the neonatal intensive care unit (n = 15), and to assess regional lung function in patients undergoing thoracic surgery (n = 55). This broadband acousto-mechanical sensing system holds the potential to help mitigate cardiorespiratory instability and manage disease progression in patients through continuous monitoring of physiological signals, in both the clinical and nonclinical setting.
- 16 November 2023
- Published by Springer Nature in Nature Medicine
- Vol. 29 (12) , 3137-3148
Top Cited PapersWireless broadband acousto-mechanical sensing system for continuous physiological monitoring
The human body generates various forms of subtle, broadband acousto-mechanical signals that contain information on cardiorespiratory and gastrointestinal health with potential application for continuous physiological monitoring. Existing device options, ranging from digital stethoscopes to inertial measurement units, offer useful capabilities but have disadvantages such as restricted measurement locations that prevent continuous, longitudinal tracking and that constrain their use to controlled environments. Here we present a wireless, broadband acousto-mechanical sensing network that circumvents these limitations and provides information on processes including slow movements within the body, digestive activity, respiratory sounds and cardiac cycles, all with clinical grade accuracy and independent of artifacts from ambient sounds. This system can also perform spatiotemporal mapping of the dynamics of gastrointestinal processes and airflow into and out of the lungs. To demonstrate the capabilities of this system we used it to monitor constrained respiratory airflow and intestinal motility in neonates in the neonatal intensive care unit (n = 15), and to assess regional lung function in patients undergoing thoracic surgery (n = 55). This broadband acousto-mechanical sensing system holds the potential to help mitigate cardiorespiratory instability and manage disease progression in patients through continuous monitoring of physiological signals, in both the clinical and nonclinical setting.
- Top Cited Papers
- 2 October 2023
- Published by Springer Nature in Nature Biomedical Engineering
- Vol. 7 (10) , 1229-1241
Synchronized wearables for the detection of haemodynamic states via electrocardiography and multispectral photoplethysmography
Cardiovascular health is typically monitored by measuring blood pressure. Here we describe a wireless on-skin system consisting of synchronized sensors for chest electrocardiography and peripheral multispectral photoplethysmography for the continuous monitoring of metrics related to vascular resistance, cardiac output and blood-pressure regulation. We used data from the sensors to train a support-vector-machine model for the classification of haemodynamic states (resulting from exposure to heat or cold, physical exercise, breath holding, performing the Valsalva manoeuvre or from vasopressor administration during post-operative hypotension) that independently affect blood pressure, cardiac output and vascular resistance. The model classified the haemodynamic states on the basis of an unseen subset of sensor data for 10 healthy individuals, 20 patients with hypertension undergoing haemodynamic stimuli and 15 patients recovering from cardiac surgery, with an average precision of 0.878 and an overall area under the receiver operating characteristic curve of 0.958. The multinodal sensor system may provide clinically actionable insights into haemodynamic states for use in the management of cardiovascular disease.
- 2 October 2023
- Published by Springer Nature in Nature Biomedical Engineering
- Vol. 7 (10) , 1229-1241
Top Cited PapersSynchronized wearables for the detection of haemodynamic states via electrocardiography and multispectral photoplethysmography
Cardiovascular health is typically monitored by measuring blood pressure. Here we describe a wireless on-skin system consisting of synchronized sensors for chest electrocardiography and peripheral multispectral photoplethysmography for the continuous monitoring of metrics related to vascular resistance, cardiac output and blood-pressure regulation. We used data from the sensors to train a support-vector-machine model for the classification of haemodynamic states (resulting from exposure to heat or cold, physical exercise, breath holding, performing the Valsalva manoeuvre or from vasopressor administration during post-operative hypotension) that independently affect blood pressure, cardiac output and vascular resistance. The model classified the haemodynamic states on the basis of an unseen subset of sensor data for 10 healthy individuals, 20 patients with hypertension undergoing haemodynamic stimuli and 15 patients recovering from cardiac surgery, with an average precision of 0.878 and an overall area under the receiver operating characteristic curve of 0.958. The multinodal sensor system may provide clinically actionable insights into haemodynamic states for use in the management of cardiovascular disease.
- Top Cited Papers
- 27 April 2023
- Published by Springer Nature in Nature Biomedical Engineering
- Vol. 7 (10) , 1252-1269
A wireless and battery-less implant for multimodal closed-loop neuromodulation in small animals
- 27 April 2023
- Published by Springer Nature in Nature Biomedical Engineering
- Vol. 7 (10) , 1252-1269
Top Cited PapersA wireless and battery-less implant for multimodal closed-loop neuromodulation in small animals
- Open Access
- 6 May 2021
- Published by JMIR Publications Inc. in JMIR mHealth and uHealth
- Vol. 9 (5) , e25895
Real-Time UV Measurement With a Sun Protection System for Warning Young Adults About Sunburn: Prospective Cohort Study
Background: Melanoma is attributable to predisposing phenotypical factors, such as skin that easily sunburns and unprotected exposure to carcinogenic UV radiation. Reducing the proportion of young adults who get sunburned may reduce the incidence of melanoma, a deadly form of skin cancer. Advances in technology have enabled the delivery of real-time UV light exposure and content-relevant health interventions. Objective: This study aims to examine the feasibility of young adults performing the following tasks daily: wearing a UV dosimeter, receiving text messages and real-time UV-B doses on their smartphone, and responding to daily web-based surveys about sunburn and sun protection. Methods: Young adults aged 18-39 years (n=42) were recruited in the United States in June 2020 via social media. Participants received the UV Guard sun protection system, which consisted of a UV dosimeter and a smartphone app. During 3 consecutive periods, intervention intensity increased as follows: real-time UV-B dose; UV-B dose and daily behavioral facilitation text messages; and UV-B dose, goal setting, and daily text messages to support self-efficacy and self-regulation. Data were self-reported through daily web-based surveys for 28 days, and UV-B doses were transmitted to cloud-based storage. Results: Patients’ median age was 22 years (IQR 20, 29), and all patients had sun-sensitive skin. Sunburns were experienced during the study by fewer subjects (n=18) than those in the preceding 28 days (n=30). In July and August, the face was the most commonly sunburned area among 13 body locations; 52% (22/42) of sunburns occurred before the study and 45% (19/42) occurred during the study. The mean daily UV-B dose decreased during the 3 periods; however, this was not statistically significant. Young adults were most often exercising outdoors from 2 to 6 PM, walking from 10 AM to 6 PM, and relaxing from noon to 2 PM. Sunburn was most often experienced during exercise (odds ratio [OR] 5.65, 95% CI 1.60-6.10) and relaxation (OR 3.69, 95% CI 1.03-4.67) relative to those that did not exercise or relax in each category. The self-reported exit survey indicated that participants felt that they spent less time outdoors this summer compared to the last summer because of the COVID-19 pandemic and work. In addition, 38% (16/42) of the participants changed their use of sun protection based on their app-reported UV exposure, and 48% (20/42) shifted the time they went outside to periods with less-intense UV exposure. A total of 79% (33/42) of the participants were willing to continue using the UV Guard system outside of a research setting. Conclusions: In this proof-of-concept research, young adults demonstrated that they used the UV Guard system; however, optimization was needed. Although some sun protection behaviors changed, sunburn was not prevented in all participants, especially during outdoor exercise. Trial Registration: ClinicalTrials.gov NCT03344796; http://clinicaltrials.gov/ct2/show/NCT03344796
- 6 May 2021
- Published by JMIR Publications Inc. in JMIR mHealth and uHealth
- Vol. 9 (5) , e25895
Open AccessReal-Time UV Measurement With a Sun Protection System for Warning Young Adults About Sunburn: Prospective Cohort Study
Background: Melanoma is attributable to predisposing phenotypical factors, such as skin that easily sunburns and unprotected exposure to carcinogenic UV radiation. Reducing the proportion of young adults who get sunburned may reduce the incidence of melanoma, a deadly form of skin cancer. Advances in technology have enabled the delivery of real-time UV light exposure and content-relevant health interventions. Objective: This study aims to examine the feasibility of young adults performing the following tasks daily: wearing a UV dosimeter, receiving text messages and real-time UV-B doses on their smartphone, and responding to daily web-based surveys about sunburn and sun protection. Methods: Young adults aged 18-39 years (n=42) were recruited in the United States in June 2020 via social media. Participants received the UV Guard sun protection system, which consisted of a UV dosimeter and a smartphone app. During 3 consecutive periods, intervention intensity increased as follows: real-time UV-B dose; UV-B dose and daily behavioral facilitation text messages; and UV-B dose, goal setting, and daily text messages to support self-efficacy and self-regulation. Data were self-reported through daily web-based surveys for 28 days, and UV-B doses were transmitted to cloud-based storage. Results: Patients’ median age was 22 years (IQR 20, 29), and all patients had sun-sensitive skin. Sunburns were experienced during the study by fewer subjects (n=18) than those in the preceding 28 days (n=30). In July and August, the face was the most commonly sunburned area among 13 body locations; 52% (22/42) of sunburns occurred before the study and 45% (19/42) occurred during the study. The mean daily UV-B dose decreased during the 3 periods; however, this was not statistically significant. Young adults were most often exercising outdoors from 2 to 6 PM, walking from 10 AM to 6 PM, and relaxing from noon to 2 PM. Sunburn was most often experienced during exercise (odds ratio [OR] 5.65, 95% CI 1.60-6.10) and relaxation (OR 3.69, 95% CI 1.03-4.67) relative to those that did not exercise or relax in each category. The self-reported exit survey indicated that participants felt that they spent less time outdoors this summer compared to the last summer because of the COVID-19 pandemic and work. In addition, 38% (16/42) of the participants changed their use of sun protection based on their app-reported UV exposure, and 48% (20/42) shifted the time they went outside to periods with less-intense UV exposure. A total of 79% (33/42) of the participants were willing to continue using the UV Guard system outside of a research setting. Conclusions: In this proof-of-concept research, young adults demonstrated that they used the UV Guard system; however, optimization was needed. Although some sun protection behaviors changed, sunburn was not prevented in all participants, especially during outdoor exercise. Trial Registration: ClinicalTrials.gov NCT03344796; http://clinicaltrials.gov/ct2/show/NCT03344796
- Open Access
- 19 November 2020
- Published by JMIR Publications Inc. in JMIR Preprints
Real-Time UV Measurement With a Sun Protection System for Warning Young Adults About Sunburn: Prospective Cohort Study (Preprint)
BACKGROUND Melanoma is attributable to predisposing phenotypical factors, such as skin that easily sunburns and unprotected exposure to carcinogenic UV radiation. Reducing the proportion of young adults who get sunburned may reduce the incidence of melanoma, a deadly form of skin cancer. Advances in technology have enabled the delivery of real-time UV light exposure and content-relevant health interventions. OBJECTIVE This study aims to examine the feasibility of young adults performing the following tasks daily: wearing a UV dosimeter, receiving text messages and real-time UV-B doses on their smartphone, and responding to daily web-based surveys about sunburn and sun protection. METHODS Young adults aged 18-39 years (n=42) were recruited in the United States in June 2020 via social media. Participants received the UV Guard sun protection system, which consisted of a UV dosimeter and a smartphone app. During 3 consecutive periods, intervention intensity increased as follows: real-time UV-B dose; UV-B dose and daily behavioral facilitation text messages; and UV-B dose, goal setting, and daily text messages to support self-efficacy and self-regulation. Data were self-reported through daily web-based surveys for 28 days, and UV-B doses were transmitted to cloud-based storage. RESULTS Patients’ median age was 22 years (IQR 20, 29), and all patients had sun-sensitive skin. Sunburns were experienced during the study by fewer subjects (n=18) than those in the preceding 28 days (n=30). In July and August, the face was the most commonly sunburned area among 13 body locations; 52% (22/42) of sunburns occurred before the study and 45% (19/42) occurred during the study. The mean daily UV-B dose decreased during the 3 periods; however, this was not statistically significant. Young adults were most often exercising outdoors from 2 to 6 PM, walking from 10 AM to 6 PM, and relaxing from noon to 2 PM. Sunburn was most often experienced during exercise (odds ratio [OR] 5.65, 95% CI 1.60-6.10) and relaxation (OR 3.69, 95% CI 1.03-4.67) relative to those that did not exercise or relax in each category. The self-reported exit survey indicated that participants felt that they spent less time outdoors this summer compared to the last summer because of the COVID-19 pandemic and work. In addition, 38% (16/42) of the participants changed their use of sun protection based on their app-reported UV exposure, and 48% (20/42) shifted the time they went outside to periods with less-intense UV exposure. A total of 79% (33/42) of the participants were willing to continue using the UV Guard system outside of a research setting. CONCLUSIONS In this proof-of-concept research, young adults demonstrated that they used the UV Guard system; however, optimization was needed. Although some sun protection behaviors changed, sunburn was not prevented in all participants, especially during outdoor exercise. CLINICALTRIAL ClinicalTrials.gov NCT03344796; http://clinicaltrials.gov/ct2/show/NCT03344796
- 19 November 2020
- Published by JMIR Publications Inc. in JMIR Preprints
Open AccessReal-Time UV Measurement With a Sun Protection System for Warning Young Adults About Sunburn: Prospective Cohort Study (Preprint)
BACKGROUND Melanoma is attributable to predisposing phenotypical factors, such as skin that easily sunburns and unprotected exposure to carcinogenic UV radiation. Reducing the proportion of young adults who get sunburned may reduce the incidence of melanoma, a deadly form of skin cancer. Advances in technology have enabled the delivery of real-time UV light exposure and content-relevant health interventions. OBJECTIVE This study aims to examine the feasibility of young adults performing the following tasks daily: wearing a UV dosimeter, receiving text messages and real-time UV-B doses on their smartphone, and responding to daily web-based surveys about sunburn and sun protection. METHODS Young adults aged 18-39 years (n=42) were recruited in the United States in June 2020 via social media. Participants received the UV Guard sun protection system, which consisted of a UV dosimeter and a smartphone app. During 3 consecutive periods, intervention intensity increased as follows: real-time UV-B dose; UV-B dose and daily behavioral facilitation text messages; and UV-B dose, goal setting, and daily text messages to support self-efficacy and self-regulation. Data were self-reported through daily web-based surveys for 28 days, and UV-B doses were transmitted to cloud-based storage. RESULTS Patients’ median age was 22 years (IQR 20, 29), and all patients had sun-sensitive skin. Sunburns were experienced during the study by fewer subjects (n=18) than those in the preceding 28 days (n=30). In July and August, the face was the most commonly sunburned area among 13 body locations; 52% (22/42) of sunburns occurred before the study and 45% (19/42) occurred during the study. The mean daily UV-B dose decreased during the 3 periods; however, this was not statistically significant. Young adults were most often exercising outdoors from 2 to 6 PM, walking from 10 AM to 6 PM, and relaxing from noon to 2 PM. Sunburn was most often experienced during exercise (odds ratio [OR] 5.65, 95% CI 1.60-6.10) and relaxation (OR 3.69, 95% CI 1.03-4.67) relative to those that did not exercise or relax in each category. The self-reported exit survey indicated that participants felt that they spent less time outdoors this summer compared to the last summer because of the COVID-19 pandemic and work. In addition, 38% (16/42) of the participants changed their use of sun protection based on their app-reported UV exposure, and 48% (20/42) shifted the time they went outside to periods with less-intense UV exposure. A total of 79% (33/42) of the participants were willing to continue using the UV Guard system outside of a research setting. CONCLUSIONS In this proof-of-concept research, young adults demonstrated that they used the UV Guard system; however, optimization was needed. Although some sun protection behaviors changed, sunburn was not prevented in all participants, especially during outdoor exercise. CLINICALTRIAL ClinicalTrials.gov NCT03344796; http://clinicaltrials.gov/ct2/show/NCT03344796