TWTao Wang

Tao Wang

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Tao Wang has a total of 10 co-authors. Here are the top co-authors by number of shared publications:

  • Weiguang An

    Key Laboratory of Gas and Fire Control for Coal Mines, China University of Mining and Technology, Xuzhou, China

    3 shared publications
  • Kaiyang Hu

    Jiangsu Key Laboratory of Fire Safety in Urban Underground Space, China University of Mining and Technology, Xuzhou 221116, China

    2 shared publications
  • Lujun Peng

    Jiangsu Key Laboratory of Fire Safety in Urban Underground Space, China University of Mining and Technology, Xuzhou 221116, China

    2 shared publications
  • Song Li

    Jiangsu Key Laboratory of Fire Safety in Urban Underground Space, China University of Mining and Technology, Xuzhou 221116, China

    2 shared publications
  • Kai Liang

    Jiangsu Key Laboratory of Fire Safety in Urban Underground Space, China University of Mining and Technology, Xuzhou 221116, China

    1 shared publication
  • Minglun Cai

    Jiangsu Key Laboratory of Fire Safety in Urban Underground Space, China University of Mining and Technology, Xuzhou 221116, China

    1 shared publication

Latest Publications

  • Open Access

    Thermodynamic and Kinetic Characteristics of Combustion of Discrete Polymethyl Methacrylate Plates with Different Spacings in Concave Building Facades

    by Weiguang An, Lujun Peng, Minglun Cai, Kaiyang Hu, Song Li, Tao Wang

    Polymethyl methacrylate plates are widely applied to buildings, producing significant fire hazards. It lacks a theoretical basis for the fire risk assessment of polymethyl methacrylate in concave building facades. Therefore, experimental methods are used to investigate combustion characteristics of discrete polymethyl methacrylate plates in a concave building facade. Influences of fuel coverage and structure factor are investigated, which is scant in previous works. When structure factor is invariable, average flame height increases first and then decreases as fuel coverage increases, and the turning point is between 0.64 and 0.76. In total, three different patterns of pyrolysis front propagation are first observed for different fuel coverages. Flame spread rate first increases and then decreases as fuel coverage rises, and the turning point is also between 0.64 and 0.76. When fuel coverage is invariable, the flame spread rate first increases and then decreases with increasing structure factor, and the turning point is 1.2. A model for predicting the flame spread rate of discrete polymethyl methacrylate is also developed. The predicted values are consistent with experimental results. Fuel spread rate of discrete polymethyl methacrylate rises as the fuel coverage increases. The above results are beneficial for thermal hazard evaluation and fire safety design of polymethyl methacrylate used in buildings.


  • Open Access

    Effects of Overlap Length on Flammability and Fire Hazard of Vertical Polymethyl Methacrylate (PMMA) Plate Array

    by Weiguang An, Kaiyang Hu, Tao Wang, Lujun Peng, Song Li, Xiangming Hu

    Polymethyl methacrylate (PMMA) plates are widely used in buildings or factories for natural lighting. Commonly PMMA plates are installed as a discrete array. However, PMMA plates are very susceptible to fire. Therefore, experimental study on flammability and fire hazard of vertical PMMA plate array with different overlap length (D) was conducted in this work. The average flame height (Hf) increases first and then decreases with an increase in the overlap length, and reaches the maximum when D = 40 mm. The discrete flame spread speed (Vf) also rises first and then drops with the increase of D, which is mainly due to the heat transfer from the PMMA flame to the next plate. A model for predicting the flame spread rate of discrete PMMA array is established. The predicted results are consistent with experimental ones, with a predicted error smaller than 15%. The average temperature of flame zone rises first and then drops as D increases, reaching the maximum when D = 40 mm. This leads to the same changing trend of radiative heat flux. Results obtained in this work provide a reference for fire hazard evaluation and fire safety design of PMMA plates employed in buildings or industrial sites.


  • Open Access

    Experimental Study on Flammability and Flame Spread Characteristics of Polyvinyl Chloride (PVC) Cable

    by Weiguang An, Yanhua Tang, Kai Liang, Tao Wang, Yang Zhou, Zhijie Wen

    Polyvinyl chloride (PVC) is widely applied in cables as insulation materials, which are vital for operation and control of industrial processes. However, PVC cables fires frequently occur, arousing public concern. Therefore, experimental methods are used to study flammability and flame-spread characteristics of PVC cable in this paper. Influences of cable structure and number are investigated, which is scanty in previous works. As cable core number of single cable or cable number of multiple cables rises, average flame height and width increase while the increment decreases. Formulas concerning dimensionless flame height and single cable diameter (or total width of multiple cables) are obtained. The former is negatively correlated with the latter. For single cable, convective heat transfer is dominant, and flame-spread rate decreases as cable core number increases. Cable maximum temperature, which drops first and then rises as cable core number increases, is observed in the cable core area. For multiple cable, the flame-spread rate increases as cable number increases. As the cable number rises, the length of pyrolysis and combustion zone increases while the maximum temperature of cable surface decreases. This work is beneficial to fire hazard evaluation and safety design of PVC cables.