Hiroshi Isoda
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Hiroshi Isoda has a total of 55 co-authors. Here are the top co-authors by number of shared publications:
- Solomon Tesfamariam
University of Waterloo
5 shared publications Takafumi Nakagawa
Kyoto Univ
5 shared publicationsMikio Koshihara
Institute of Industrial Science, The University of Tokyo
4 shared publicationsTatsuya Miyake
Nihon System Sekkei Architects and Engineers
3 shared publications- Tokikatsu Namba
Department of Building Materials and Components, Building Research Institute, Tsukuba 3050802, Ibaraki, Japan
3 shared publications - Yasuhiro Araki
Building Research Institute, National Institute for Land and Infrastructure Management
3 shared publications
Latest Publications
- 1 December 2025
- Published by American Society of Civil Engineers (ASCE) in Journal of Performance of Constructed Facilities
- Vol. 39 (6)
Collapse Behavior of Platform-Type CLT Construction Using Shake-Table Experimental Tests
- 1 December 2025
- Published by American Society of Civil Engineers (ASCE) in Journal of Performance of Constructed Facilities
- Vol. 39 (6)
Collapse Behavior of Platform-Type CLT Construction Using Shake-Table Experimental Tests
- Open Access
- 28 August 2025
- Published by Elsevier in Journal of Building Engineering
- Vol. 112
Feasibility study on the seismic performance evaluation of RC frame with coupled CLT infill panels
- 28 August 2025
- Published by Elsevier in Journal of Building Engineering
- Vol. 112
Open AccessFeasibility study on the seismic performance evaluation of RC frame with coupled CLT infill panels
- Open Access
- 5 August 2025
- Published by Elsevier in Engineering Structures
- Vol. 343
Shake table test of a full-scale ten-story mass timber building designed with Japanese building standard law
- 5 August 2025
- Published by Elsevier in Engineering Structures
- Vol. 343
Open AccessShake table test of a full-scale ten-story mass timber building designed with Japanese building standard law
- 1 July 2023
- Published by American Society of Civil Engineers (ASCE) in Journal of Structural Engineering
- Vol. 149 (7)
Seismic Response Comparison of Full-Scale Moment-Resisting Timber Frame and Joint Test Result
- 1 July 2023
- Published by American Society of Civil Engineers (ASCE) in Journal of Structural Engineering
- Vol. 149 (7)
Seismic Response Comparison of Full-Scale Moment-Resisting Timber Frame and Joint Test Result
- 1 October 2021
- Published by American Society of Civil Engineers (ASCE) in Journal of Performance of Constructed Facilities
- Vol. 35 (5) , 04021043
Shake Table Test of Full-Size Wooden Houses versus Wall Test Result: Comparison of Load-Deformation Relationship
The design procedure considered in the Japanese code for low-rise timber houses (two or fewer stories), is through a wall volume method. The wall volume method entails calculating the shear capacity of each wall through addition of shear walls. However, past earthquake damages highlighted the vulnerability of light timber structures and warrant detailed evaluations to assess the design practice. In this study, load-deformation ( ) relations of the wall are combined to estimate the story shear drift. The general calculation of the amount of walls as a design method for a house is very simple. Buildings damaged in recent earthquakes have become of a concern to decision makers, owners, and designers. To validate the wall volume method, 21 full-scale shake table tests are compared with static wall test results. From the analytical and experimental studies, the short-term allowable shear strength in design with the full-scale experiment is about 2.25 times the standard method and about 2.0 times the quality verification method. Regarding the relationship, the rigidity and maximum load obtained from the experimental tests are 1.2 and 1.3 times larger than the addition, respectively. This paper has highlighted also influences of nonstructural members on the overall response of the structures.- 1 October 2021
- Published by American Society of Civil Engineers (ASCE) in Journal of Performance of Constructed Facilities
- Vol. 35 (5) , 04021043
Shake Table Test of Full-Size Wooden Houses versus Wall Test Result: Comparison of Load-Deformation Relationship
The design procedure considered in the Japanese code for low-rise timber houses (two or fewer stories), is through a wall volume method. The wall volume method entails calculating the shear capacity of each wall through addition of shear walls. However, past earthquake damages highlighted the vulnerability of light timber structures and warrant detailed evaluations to assess the design practice. In this study, load-deformation ( ) relations of the wall are combined to estimate the story shear drift. The general calculation of the amount of walls as a design method for a house is very simple. Buildings damaged in recent earthquakes have become of a concern to decision makers, owners, and designers. To validate the wall volume method, 21 full-scale shake table tests are compared with static wall test results. From the analytical and experimental studies, the short-term allowable shear strength in design with the full-scale experiment is about 2.25 times the standard method and about 2.0 times the quality verification method. Regarding the relationship, the rigidity and maximum load obtained from the experimental tests are 1.2 and 1.3 times larger than the addition, respectively. This paper has highlighted also influences of nonstructural members on the overall response of the structures.- 1 February 2021
- Published by American Society of Civil Engineers (ASCE) in Journal of Structural Engineering
- Vol. 147 (2) , 04020323
Seismic Testing and Analysis of Rocking Motions of Japanese Post-and-Beam Construction
From our investigation of the experimental seismic response of post-and-beam wooden buildings with different column joints, we developed a nonlinear three-dimensional distinct element model that is capable of time-history response analysis. This model succeeded in predicting the seismic response of the column-base, such as rocking behavior, which has been difficult. Four types of full-scale post-and-beam wooden structures with various column-base systems were tested on a shaking table with three ground-motion sequences for each type of structure, and their response and performance were investigated. By comparing the model’s predictions with the test results, we confirmed the rocking–tracking accuracy of the analysis program. The numerical model was reasonably able to keep pace with the measured experimental response in terms of load-deformation curves, following uplifts and pull-out behavior as observed at the column bottoms in the shake-table tests. The model was also able to predict maximum response acceleration and global interstory drift within 10% accuracy on average. Considering the large uncertainties associated with seismic-collapse predictions, such as complicated nonlinear behavior in frames and joints, these results encourage researchers and designers to understand how these structures respond to earthquakes and how to analyze these structures.
- 1 February 2021
- Published by American Society of Civil Engineers (ASCE) in Journal of Structural Engineering
- Vol. 147 (2) , 04020323
Seismic Testing and Analysis of Rocking Motions of Japanese Post-and-Beam Construction
From our investigation of the experimental seismic response of post-and-beam wooden buildings with different column joints, we developed a nonlinear three-dimensional distinct element model that is capable of time-history response analysis. This model succeeded in predicting the seismic response of the column-base, such as rocking behavior, which has been difficult. Four types of full-scale post-and-beam wooden structures with various column-base systems were tested on a shaking table with three ground-motion sequences for each type of structure, and their response and performance were investigated. By comparing the model’s predictions with the test results, we confirmed the rocking–tracking accuracy of the analysis program. The numerical model was reasonably able to keep pace with the measured experimental response in terms of load-deformation curves, following uplifts and pull-out behavior as observed at the column bottoms in the shake-table tests. The model was also able to predict maximum response acceleration and global interstory drift within 10% accuracy on average. Considering the large uncertainties associated with seismic-collapse predictions, such as complicated nonlinear behavior in frames and joints, these results encourage researchers and designers to understand how these structures respond to earthquakes and how to analyze these structures.
- Open Access
- 1 January 2020
- Published by Architectural Institute of Japan in Journal of Structural and Construction Engineering (Transactions of AIJ)
- Vol. 85 (770) , 521-527
A STUDY ON THE REDUCTION OF PROOF STRESS BY SMALL OPENING OF EQUIPMENT FOR CLT PANEL
In the case of both narrow panels and large panels, the CLT panel, which is the load bearing wall, may be provided with a small opening for building equipment. In this study, in order to confirm the influence of the presence and the position of the small opening on the yield strength and stiffness under the bending test and the shear test of the CLT panel with the small opening were conducted. This report reports on test results and their considerations. Test results and calculated values were compared for the value of the moment of inertia when the specimen was considered as a uniform cross section over the entire length under the bending test. Although the moment of inertia calculated by calculation substantially matches the one obtained by the test result, the moment of inertia I' of the notched portion of the specimen having a shape in which either upper or lower of the specimen is cut out Is overrated. They matched when I' was set to 0.6 times when there was a notch. Although it is necessary to study the adjustment coefficient in the future. If there is a notch on the top and bottom, calculating as a simple cross-sectional defect may result in a dangerous side. Regarding the shear elastic modulus, the shape that is cut out at the top of the specimen is slightly higher than the other shapes and tends to be slightly lower in the case of the central opening, but is considered to be within the range of variation. The bending strength was calculated from the bending test results. Although there was no significant difference in bending strength depending on existing or no opening and the position of the opening, the bending strength of the specimen with the opening at the upper end had a value of 1.43 times. In addition, comparing the two specimens in which the opening position is vertically symmetrical, the value of the specimen with the opening on the upper side was somewhat lower. In order to confirm the influence of the fluctuation of the test piece strength on the calculation result, the bending strength was calculated on the assumption that all the test pieces were damaged with the same strain. It almost agreed with the bending strength calculated from the test results. It can be confirmed that the failure occurred at a somewhat low strain in the specimen with the opening at the center in the beam depth. The shear strength calculated from the shear test results does not show large deference due to the existing or no opening and the position of the opening. If the size of the opening this time, it was shown that the shear strength could be obtained by simple calculation without depending on the position of the opening.
- 1 January 2020
- Published by Architectural Institute of Japan in Journal of Structural and Construction Engineering (Transactions of AIJ)
- Vol. 85 (770) , 521-527
Open AccessA STUDY ON THE REDUCTION OF PROOF STRESS BY SMALL OPENING OF EQUIPMENT FOR CLT PANEL
In the case of both narrow panels and large panels, the CLT panel, which is the load bearing wall, may be provided with a small opening for building equipment. In this study, in order to confirm the influence of the presence and the position of the small opening on the yield strength and stiffness under the bending test and the shear test of the CLT panel with the small opening were conducted. This report reports on test results and their considerations. Test results and calculated values were compared for the value of the moment of inertia when the specimen was considered as a uniform cross section over the entire length under the bending test. Although the moment of inertia calculated by calculation substantially matches the one obtained by the test result, the moment of inertia I' of the notched portion of the specimen having a shape in which either upper or lower of the specimen is cut out Is overrated. They matched when I' was set to 0.6 times when there was a notch. Although it is necessary to study the adjustment coefficient in the future. If there is a notch on the top and bottom, calculating as a simple cross-sectional defect may result in a dangerous side. Regarding the shear elastic modulus, the shape that is cut out at the top of the specimen is slightly higher than the other shapes and tends to be slightly lower in the case of the central opening, but is considered to be within the range of variation. The bending strength was calculated from the bending test results. Although there was no significant difference in bending strength depending on existing or no opening and the position of the opening, the bending strength of the specimen with the opening at the upper end had a value of 1.43 times. In addition, comparing the two specimens in which the opening position is vertically symmetrical, the value of the specimen with the opening on the upper side was somewhat lower. In order to confirm the influence of the fluctuation of the test piece strength on the calculation result, the bending strength was calculated on the assumption that all the test pieces were damaged with the same strain. It almost agreed with the bending strength calculated from the test results. It can be confirmed that the failure occurred at a somewhat low strain in the specimen with the opening at the center in the beam depth. The shear strength calculated from the shear test results does not show large deference due to the existing or no opening and the position of the opening. If the size of the opening this time, it was shown that the shear strength could be obtained by simple calculation without depending on the position of the opening.