Z. B. Kardanakhishvili
Research Subjects
Research Interests
Z. B. Kardanakhishvili has a total of 12 co-authors. Here are the top co-authors by number of shared publications:
- Dmitry S. Bubnov
Chazov National Medical Research Center of Cardiology
2 shared publications - R. V. Atanesyan
Chazov National Medical Research Center of Cardiology
2 shared publications - Aleksei B. Zulkarnaev
M.F. Vladimirsky Moscow Regional Research Clinical Institute
1 shared publication - Fail T. Ageev
Out-Patient Department, National Medical Research Center of Cardiology Named after Academician E.I. Chazov, Academician Chazov St., 15a, 121552 Moscow, Russia
1 shared publication M. E. Zhadkevich Moscow City Clinical Hospital of the Department of Health Care of Moscow
1 shared publicationMoscow Hospital No2 for War Veterans of the Department of Health Care of Moscow
1 shared publication
Latest Publications
- Open Access
- 22 November 2023
- Published by Intermedservice Ltd in Eurasian heart journal
- No. 4,p. 32-40
Reproducibility of instantaneous wave-free ratio and angiography coregistration in patients with coronary heart disease and diffuse and multilevel coronary artery lesion
Aim. To determine the reproducibility of the results of instantaneous wavefree ratio (iFR) and angiography coregistration in patients with coronary heart disease (CAD) with multilevel and diffuse lesions of the coronary arteries.Materials and methods. The study included 34 patients with chronic ischemic heart disease (CAD) with diffuse and/or multilevel coronary stenoses >50%. In 41 coronary arteries, two consecutive iFR pullback of the conductor were performed and paired iFR angio-coregistrations were formed, reflecting changes in iFR gradients (Δ iFR) along the entire length of the studied artery. To compare the results of paired studies, the following values were used: 1) indices of distal iFR; 2) maximum Δ iFR; 3) Δ iFR of all stenoses ˃50%.Results. Comparable values of distal iFR were obtained 0,84 [0,78; 0,89] vs. 0,85 [0,77; 0,88]) with an average difference of the first and second measurements of 0,001, maximum ΔiFR (0,08 [0,05; 0,14] vs. 0,08 [0,05; 0,13]) with a mean difference of -0,004 and ΔiFR of all stenoses >50% (0,05 [0,02; 0,11] vs. 0,05 [ 0,02; 0,10]) with an average difference of -0.001. Lin’s concordance correlation coefficient and Intraclass Correlation Coefficients calculated for the three parameters studied showed a good level of agreement (0,97; 0,98; 0,98) with excellent reliability (0,97; 0,98; 0,97).Conclusion. In patients with multilevel and diffuse lesions of the coronary artery, iFR angio-coregistration has a fairly high reproducibility.
- 22 November 2023
- Published by Intermedservice Ltd in Eurasian heart journal
- No. 4,p. 32-40
Open AccessReproducibility of instantaneous wave-free ratio and angiography coregistration in patients with coronary heart disease and diffuse and multilevel coronary artery lesion
Aim. To determine the reproducibility of the results of instantaneous wavefree ratio (iFR) and angiography coregistration in patients with coronary heart disease (CAD) with multilevel and diffuse lesions of the coronary arteries.Materials and methods. The study included 34 patients with chronic ischemic heart disease (CAD) with diffuse and/or multilevel coronary stenoses >50%. In 41 coronary arteries, two consecutive iFR pullback of the conductor were performed and paired iFR angio-coregistrations were formed, reflecting changes in iFR gradients (Δ iFR) along the entire length of the studied artery. To compare the results of paired studies, the following values were used: 1) indices of distal iFR; 2) maximum Δ iFR; 3) Δ iFR of all stenoses ˃50%.Results. Comparable values of distal iFR were obtained 0,84 [0,78; 0,89] vs. 0,85 [0,77; 0,88]) with an average difference of the first and second measurements of 0,001, maximum ΔiFR (0,08 [0,05; 0,14] vs. 0,08 [0,05; 0,13]) with a mean difference of -0,004 and ΔiFR of all stenoses >50% (0,05 [0,02; 0,11] vs. 0,05 [ 0,02; 0,10]) with an average difference of -0.001. Lin’s concordance correlation coefficient and Intraclass Correlation Coefficients calculated for the three parameters studied showed a good level of agreement (0,97; 0,98; 0,98) with excellent reliability (0,97; 0,98; 0,97).Conclusion. In patients with multilevel and diffuse lesions of the coronary artery, iFR angio-coregistration has a fairly high reproducibility.
- 24 April 2023
- Published by Media Sphere Publishing Group in Russian Cardiology Bulletin
- Vol. 18 (4)
Angiocoregistration of instantaneous wave-free ratio using “virtual stenting” and results of real stenting in patients with coronary artery disease and diffuse coronary artery lesions
Objective. To analyze diagnostic accuracy of instantaneous wave-free ratio with «virtual stenting» for assessing severity of coronary stenoses in patients with diffuse lesions of coronary arteries. Material and methods. The study included 57 patients with chronic coronary artery disease, diffuse and/or multilevel coronary lesions and iFR ≤0.89. «Virtual stenting» with analysis of apparent iFR before PCI was performed in 59 coronary arteries. Moreover, balloon angioplasty with stenting was followed by assessment of actual iFR after PCI. Results. We obtained similar apparent iFR before PCI (0.94 [0.92; 0.95]) and actual iFR after PCI (0.91 [0.90; 0.93]). Mean difference between these values in the overall group was 2.3±3.4%, for multilevel lesions — 2.1±3.3%, for diffuse lesions 2.8±3.7%. Absolute percentage error in the overall group was 2.21% (95% CI 1.61—3.28) and did not exceed the 95th percentile (8.11%). This finding indicates adequate accuracy of indicators predicted by iFR angiocoregistration. Conclusion. Angiocoregistration of iFR with «virtual stenting» can be used for preliminary assessment and modeling of results of elective PCI in patients with multilevel and diffuse coronary lesions.
- 24 April 2023
- Published by Media Sphere Publishing Group in Russian Cardiology Bulletin
- Vol. 18 (4)
Angiocoregistration of instantaneous wave-free ratio using “virtual stenting” and results of real stenting in patients with coronary artery disease and diffuse coronary artery lesions
Objective. To analyze diagnostic accuracy of instantaneous wave-free ratio with «virtual stenting» for assessing severity of coronary stenoses in patients with diffuse lesions of coronary arteries. Material and methods. The study included 57 patients with chronic coronary artery disease, diffuse and/or multilevel coronary lesions and iFR ≤0.89. «Virtual stenting» with analysis of apparent iFR before PCI was performed in 59 coronary arteries. Moreover, balloon angioplasty with stenting was followed by assessment of actual iFR after PCI. Results. We obtained similar apparent iFR before PCI (0.94 [0.92; 0.95]) and actual iFR after PCI (0.91 [0.90; 0.93]). Mean difference between these values in the overall group was 2.3±3.4%, for multilevel lesions — 2.1±3.3%, for diffuse lesions 2.8±3.7%. Absolute percentage error in the overall group was 2.21% (95% CI 1.61—3.28) and did not exceed the 95th percentile (8.11%). This finding indicates adequate accuracy of indicators predicted by iFR angiocoregistration. Conclusion. Angiocoregistration of iFR with «virtual stenting» can be used for preliminary assessment and modeling of results of elective PCI in patients with multilevel and diffuse coronary lesions.
- 28 October 2020
- Published by Vitebsk State Medical University in Novosti Khirurgii
- Vol. 28 (5) , 515-526
Stenting and Isolated Balloon Angioplasty for Central Venous Stenosis in Patients Undergoing Hemodialysis
Цель. Провести сравнительный анализ результатов изолированной баллонной ангиопластики и ангиопластики со стентированием при стенозе центральных вен у пациентов на гемодиализе. Материалы и методы. В ретроспективное исследование включены 62 пациента со стенозом центральных вен (СЦВ). У 39 пациентов выполнена изолированная баллонная ангиопластика (БА), у 23 пациентов БА дополнена стентированием. Результаты. Функциональная первичная проходимость артериовенозной фистулы через 1 и 3 года после БА: 89,7% [95%ДИ 74,9; 96] и 30,8% [95%ДИ 17,3; 45,4], после стентирования: 100% и 30,4% [95%ДИ 13,5; 49,3]; HR=0,8756 [95%ДИ 0,527; 1,455], p=0,5994. Первичная проходимость через 6 и 12 месяцев после БА: 61,5% [95%ДИ 44,5; 74,7] и 15,4% [95%ДИ 6,2; 28,3]; после стентирования: 82,6% [95%ДИ 60,1; 93,1] и 47,8% [95%ДИ 26,8; 66,1]; HR=0,4845 [95%ДИ 0,2938; 0,799], p=0,0017. Функциональная вторичная проходимость через 1, 3 и 4 года после БА: 100%, 74,4% [95%ДИ 57,6; 85,3] и 12,8% [95%ДИ 4,7; 25,2]; после стентирования: 100%, 91,3% [95%ДИ 69,5; 97,8] и 34,8% [95%ДИ 16,6; 53,7]; HR=0,4764 [95%ДИ 0,2888; 0,786], p=0,0016. Вторичная проходимость через 6, 12 и 24 месяца после БА: 84,6% [95%ДИ 68,9; 92,8], 66,7% [95%ДИ 49,6; 79,1] и 17,9% [95%ДИ 7,9; 31,3]; после стентирования: 91,3% [95%ДИ 69,5; 97,8], 78,3% [95%ДИ 55,4; 90,3] и 43,5% [95%ДИ 23,3; 62,1]; HR=0,4925 [95%ДИ 0,2988; 0,8119], p=0,0021. Корреляция функциональной первичной проходимости с первичной проходимостью составила r= -0,627; р<0,0001, с вторичной проходимостью – r= -0,53; р=0,0005 при БА, при стентировании – r= -0,351; р=0,101 и r= -0,304; р= 0,159 соответственно. Заключение. Результаты БА существенно зависят от давности стеноза. Применение стентов позволяет улучшить результаты вне зависимости от давности стеноза. Научная новизна статьи впервые доказано, что период времени между началом использования артериовенозной фистулы для гемодиализа и клинической манифестацией стеноза центральных вен оказывает существенное влияние на результаты эндоваскулярных вмешательств. Установлено, что эффективность баллонной ангиопластики значительно снижается при коррекции «поздних» стенозов. Применение стентов позволяет несколько улучшить результаты эндоваскулярных вмешательств при стенозе центральных вен вне зависимости от давности стеноза.
- 28 October 2020
- Published by Vitebsk State Medical University in Novosti Khirurgii
- Vol. 28 (5) , 515-526
Stenting and Isolated Balloon Angioplasty for Central Venous Stenosis in Patients Undergoing Hemodialysis
Цель. Провести сравнительный анализ результатов изолированной баллонной ангиопластики и ангиопластики со стентированием при стенозе центральных вен у пациентов на гемодиализе. Материалы и методы. В ретроспективное исследование включены 62 пациента со стенозом центральных вен (СЦВ). У 39 пациентов выполнена изолированная баллонная ангиопластика (БА), у 23 пациентов БА дополнена стентированием. Результаты. Функциональная первичная проходимость артериовенозной фистулы через 1 и 3 года после БА: 89,7% [95%ДИ 74,9; 96] и 30,8% [95%ДИ 17,3; 45,4], после стентирования: 100% и 30,4% [95%ДИ 13,5; 49,3]; HR=0,8756 [95%ДИ 0,527; 1,455], p=0,5994. Первичная проходимость через 6 и 12 месяцев после БА: 61,5% [95%ДИ 44,5; 74,7] и 15,4% [95%ДИ 6,2; 28,3]; после стентирования: 82,6% [95%ДИ 60,1; 93,1] и 47,8% [95%ДИ 26,8; 66,1]; HR=0,4845 [95%ДИ 0,2938; 0,799], p=0,0017. Функциональная вторичная проходимость через 1, 3 и 4 года после БА: 100%, 74,4% [95%ДИ 57,6; 85,3] и 12,8% [95%ДИ 4,7; 25,2]; после стентирования: 100%, 91,3% [95%ДИ 69,5; 97,8] и 34,8% [95%ДИ 16,6; 53,7]; HR=0,4764 [95%ДИ 0,2888; 0,786], p=0,0016. Вторичная проходимость через 6, 12 и 24 месяца после БА: 84,6% [95%ДИ 68,9; 92,8], 66,7% [95%ДИ 49,6; 79,1] и 17,9% [95%ДИ 7,9; 31,3]; после стентирования: 91,3% [95%ДИ 69,5; 97,8], 78,3% [95%ДИ 55,4; 90,3] и 43,5% [95%ДИ 23,3; 62,1]; HR=0,4925 [95%ДИ 0,2988; 0,8119], p=0,0021. Корреляция функциональной первичной проходимости с первичной проходимостью составила r= -0,627; р<0,0001, с вторичной проходимостью – r= -0,53; р=0,0005 при БА, при стентировании – r= -0,351; р=0,101 и r= -0,304; р= 0,159 соответственно. Заключение. Результаты БА существенно зависят от давности стеноза. Применение стентов позволяет улучшить результаты вне зависимости от давности стеноза. Научная новизна статьи впервые доказано, что период времени между началом использования артериовенозной фистулы для гемодиализа и клинической манифестацией стеноза центральных вен оказывает существенное влияние на результаты эндоваскулярных вмешательств. Установлено, что эффективность баллонной ангиопластики значительно снижается при коррекции «поздних» стенозов. Применение стентов позволяет несколько улучшить результаты эндоваскулярных вмешательств при стенозе центральных вен вне зависимости от давности стеноза.