Dmitry S. Bubnov
Dmitry S. Bubnov has a total of 16 co-authors. Here are the top co-authors by number of shared publications:
- Fail T. Ageev
Out-Patient Department, National Medical Research Center of Cardiology Named after Academician E.I. Chazov, Academician Chazov St., 15a, 121552 Moscow, Russia
3 shared publications - R. V. Atanesyan
Chazov National Medical Research Center of Cardiology
3 shared publications - Yuriy G. Matchin
E.I. Chazov National Medical Research Center Of Cardiology
3 shared publications - Natalia S. Shamrina
E.I. Chazov National Medical Research Center Of Cardiology
2 shared publications - Z. B. Kardanakhishvili
E.I. Chazov National Medical Research Center Of Cardiology
2 shared publications - Alexandra S. Ermolaeva
I.M. Sechenov First Moscow State Medical University (Sechenov University)
1 shared publication
Latest Publications
- Open Access
- 14 March 2026
- Published by Silicea - Poligraf, LLC in Cardiovascular Therapy and Prevention
- Vol. 25 (2) , 4509
Immediate and long-term outcomes of instantaneous wave-free ratio-guided endovascular treatment of patients with diffuse and multilevel coronary artery disease
Aim. To compare the immediate and long-term outcomes of percutaneous coronary intervention (PCI) with and without instantaneous wave-free ratio (iFR) monitoring in patients with diffuse and multilevel coronary artery disease (CAD). Material and methods. The study prospectively enrolled 100 patients who underwent PCI for stable CAD with diffuse and/or multilevel involvement of target coronary artery. Comparison group was retrospectively matched using a propensity score matching. The study group had iFR-guided PCI (n=100), while the comparison group — standard PCI without iFR monitoring (n=100). Long-term outcomes were assessed in 198 (99,0%) patients. Results. The study group had a lower number of implanted stents (1,2±0,4 vs 1,6±0,5; pConclusion. In patients with diffuse and multilevel coronary artery disease (CAD), iFR-guided PCI allows for a reduction in the number and length of implanted stents by eliminating the need for stenting functionally insignificant stenoses, with comparable 12-month survival to standard PCI.
- 14 March 2026
- Published by Silicea - Poligraf, LLC in Cardiovascular Therapy and Prevention
- Vol. 25 (2) , 4509
Open AccessImmediate and long-term outcomes of instantaneous wave-free ratio-guided endovascular treatment of patients with diffuse and multilevel coronary artery disease
Aim. To compare the immediate and long-term outcomes of percutaneous coronary intervention (PCI) with and without instantaneous wave-free ratio (iFR) monitoring in patients with diffuse and multilevel coronary artery disease (CAD). Material and methods. The study prospectively enrolled 100 patients who underwent PCI for stable CAD with diffuse and/or multilevel involvement of target coronary artery. Comparison group was retrospectively matched using a propensity score matching. The study group had iFR-guided PCI (n=100), while the comparison group — standard PCI without iFR monitoring (n=100). Long-term outcomes were assessed in 198 (99,0%) patients. Results. The study group had a lower number of implanted stents (1,2±0,4 vs 1,6±0,5; pConclusion. In patients with diffuse and multilevel coronary artery disease (CAD), iFR-guided PCI allows for a reduction in the number and length of implanted stents by eliminating the need for stenting functionally insignificant stenoses, with comparable 12-month survival to standard PCI.
- Open Access
- 2 May 2024
- Published by Consilium Medicum in Consilium Medicum
- Vol. 26 (1) , 7-11
Differential diagnosis of amiodarone-induced thyrotoxicosis in a patient with atrial fibrillation and agranulocytosis on the background of thyrostatic therapy. Case report
Atrial fibrillation is the most common heart rhythm disorder in patients with chronic heart failure. One of the most effective antiarrhythmic drugs for the treatment and prevention of a wide range of supraventricular and ventricular tachyarrhythmia is amiodarone. In the group of patients with paroxysmal atrial fibrillation and low left ventricular ejection fraction, it is the drug of choice when conducting a „rhythm control“ strategy. Patients receiving amiodarone often develop an adverse event – amiodarone-induced thyrotoxicosis, which exacerbates the course of cardiovascular pathology. In this article, we consider a clinical case of amiodarone-induced thyrotoxicosis in a 30-year-old patient with dilated cardiomyopathy and agranulocytosis that developed against the background of thyrostatic therapy.
- 2 May 2024
- Published by Consilium Medicum in Consilium Medicum
- Vol. 26 (1) , 7-11
Open AccessDifferential diagnosis of amiodarone-induced thyrotoxicosis in a patient with atrial fibrillation and agranulocytosis on the background of thyrostatic therapy. Case report
Atrial fibrillation is the most common heart rhythm disorder in patients with chronic heart failure. One of the most effective antiarrhythmic drugs for the treatment and prevention of a wide range of supraventricular and ventricular tachyarrhythmia is amiodarone. In the group of patients with paroxysmal atrial fibrillation and low left ventricular ejection fraction, it is the drug of choice when conducting a „rhythm control“ strategy. Patients receiving amiodarone often develop an adverse event – amiodarone-induced thyrotoxicosis, which exacerbates the course of cardiovascular pathology. In this article, we consider a clinical case of amiodarone-induced thyrotoxicosis in a 30-year-old patient with dilated cardiomyopathy and agranulocytosis that developed against the background of thyrostatic therapy.
- Open Access
- 22 November 2023
- Published by Intermedservice Ltd in Eurasian heart journal
- No. 4,p. 32-40
Reproducibility of instantaneous wave-free ratio and angiography coregistration in patients with coronary heart disease and diffuse and multilevel coronary artery lesion
Aim. To determine the reproducibility of the results of instantaneous wavefree ratio (iFR) and angiography coregistration in patients with coronary heart disease (CAD) with multilevel and diffuse lesions of the coronary arteries.Materials and methods. The study included 34 patients with chronic ischemic heart disease (CAD) with diffuse and/or multilevel coronary stenoses >50%. In 41 coronary arteries, two consecutive iFR pullback of the conductor were performed and paired iFR angio-coregistrations were formed, reflecting changes in iFR gradients (Δ iFR) along the entire length of the studied artery. To compare the results of paired studies, the following values were used: 1) indices of distal iFR; 2) maximum Δ iFR; 3) Δ iFR of all stenoses ˃50%.Results. Comparable values of distal iFR were obtained 0,84 [0,78; 0,89] vs. 0,85 [0,77; 0,88]) with an average difference of the first and second measurements of 0,001, maximum ΔiFR (0,08 [0,05; 0,14] vs. 0,08 [0,05; 0,13]) with a mean difference of -0,004 and ΔiFR of all stenoses >50% (0,05 [0,02; 0,11] vs. 0,05 [ 0,02; 0,10]) with an average difference of -0.001. Lin’s concordance correlation coefficient and Intraclass Correlation Coefficients calculated for the three parameters studied showed a good level of agreement (0,97; 0,98; 0,98) with excellent reliability (0,97; 0,98; 0,97).Conclusion. In patients with multilevel and diffuse lesions of the coronary artery, iFR angio-coregistration has a fairly high reproducibility.
- 22 November 2023
- Published by Intermedservice Ltd in Eurasian heart journal
- No. 4,p. 32-40
Open AccessReproducibility of instantaneous wave-free ratio and angiography coregistration in patients with coronary heart disease and diffuse and multilevel coronary artery lesion
Aim. To determine the reproducibility of the results of instantaneous wavefree ratio (iFR) and angiography coregistration in patients with coronary heart disease (CAD) with multilevel and diffuse lesions of the coronary arteries.Materials and methods. The study included 34 patients with chronic ischemic heart disease (CAD) with diffuse and/or multilevel coronary stenoses >50%. In 41 coronary arteries, two consecutive iFR pullback of the conductor were performed and paired iFR angio-coregistrations were formed, reflecting changes in iFR gradients (Δ iFR) along the entire length of the studied artery. To compare the results of paired studies, the following values were used: 1) indices of distal iFR; 2) maximum Δ iFR; 3) Δ iFR of all stenoses ˃50%.Results. Comparable values of distal iFR were obtained 0,84 [0,78; 0,89] vs. 0,85 [0,77; 0,88]) with an average difference of the first and second measurements of 0,001, maximum ΔiFR (0,08 [0,05; 0,14] vs. 0,08 [0,05; 0,13]) with a mean difference of -0,004 and ΔiFR of all stenoses >50% (0,05 [0,02; 0,11] vs. 0,05 [ 0,02; 0,10]) with an average difference of -0.001. Lin’s concordance correlation coefficient and Intraclass Correlation Coefficients calculated for the three parameters studied showed a good level of agreement (0,97; 0,98; 0,98) with excellent reliability (0,97; 0,98; 0,97).Conclusion. In patients with multilevel and diffuse lesions of the coronary artery, iFR angio-coregistration has a fairly high reproducibility.
- 24 April 2023
- Published by Media Sphere Publishing Group in Russian Cardiology Bulletin
- Vol. 18 (4)
Angiocoregistration of instantaneous wave-free ratio using “virtual stenting” and results of real stenting in patients with coronary artery disease and diffuse coronary artery lesions
Objective. To analyze diagnostic accuracy of instantaneous wave-free ratio with «virtual stenting» for assessing severity of coronary stenoses in patients with diffuse lesions of coronary arteries. Material and methods. The study included 57 patients with chronic coronary artery disease, diffuse and/or multilevel coronary lesions and iFR ≤0.89. «Virtual stenting» with analysis of apparent iFR before PCI was performed in 59 coronary arteries. Moreover, balloon angioplasty with stenting was followed by assessment of actual iFR after PCI. Results. We obtained similar apparent iFR before PCI (0.94 [0.92; 0.95]) and actual iFR after PCI (0.91 [0.90; 0.93]). Mean difference between these values in the overall group was 2.3±3.4%, for multilevel lesions — 2.1±3.3%, for diffuse lesions 2.8±3.7%. Absolute percentage error in the overall group was 2.21% (95% CI 1.61—3.28) and did not exceed the 95th percentile (8.11%). This finding indicates adequate accuracy of indicators predicted by iFR angiocoregistration. Conclusion. Angiocoregistration of iFR with «virtual stenting» can be used for preliminary assessment and modeling of results of elective PCI in patients with multilevel and diffuse coronary lesions.
- 24 April 2023
- Published by Media Sphere Publishing Group in Russian Cardiology Bulletin
- Vol. 18 (4)
Angiocoregistration of instantaneous wave-free ratio using “virtual stenting” and results of real stenting in patients with coronary artery disease and diffuse coronary artery lesions
Objective. To analyze diagnostic accuracy of instantaneous wave-free ratio with «virtual stenting» for assessing severity of coronary stenoses in patients with diffuse lesions of coronary arteries. Material and methods. The study included 57 patients with chronic coronary artery disease, diffuse and/or multilevel coronary lesions and iFR ≤0.89. «Virtual stenting» with analysis of apparent iFR before PCI was performed in 59 coronary arteries. Moreover, balloon angioplasty with stenting was followed by assessment of actual iFR after PCI. Results. We obtained similar apparent iFR before PCI (0.94 [0.92; 0.95]) and actual iFR after PCI (0.91 [0.90; 0.93]). Mean difference between these values in the overall group was 2.3±3.4%, for multilevel lesions — 2.1±3.3%, for diffuse lesions 2.8±3.7%. Absolute percentage error in the overall group was 2.21% (95% CI 1.61—3.28) and did not exceed the 95th percentile (8.11%). This finding indicates adequate accuracy of indicators predicted by iFR angiocoregistration. Conclusion. Angiocoregistration of iFR with «virtual stenting» can be used for preliminary assessment and modeling of results of elective PCI in patients with multilevel and diffuse coronary lesions.
- Open Access
- 24 October 2022
- Published by Consilium Medicum in Terapevticheskii arkhiv
- Vol. 94 (9) , 1062-1066
Remote electrocardiogram telemonitoring after endovascular interventions on the coronary arteries
Aim. To evaluate the effectiveness of a new system for telemetric electrocardiogram (ECG) monitoring in patients after endovascular interventions (EI) on the coronary arteries (CA). Materials and methods. 168 patients with chronic ischemic heart disease who underwent EI on the CA on an outpatient basis, and during routine hospitalization, followed by telemetric ECG-monitoring after interventions were included. The monitoring was carried out using a three-channel telemetric recorder Astrocard HE3 (Russia), which provides continuous monitoring of 3-lead ECG for a long time. Results. The telemetry was successfully performed in all 168 (100%) patients. In 165 (98%) patients, the quality of the recording was regarded as good, in 3 (2%) as satisfactory. There were no cases of disconnection of the device, no interruptions in recording. During the observation period, no life-threatening arrhythmia revealed. When comparing the telemetry results in different groups of patients, there were no significant differences in the incidence of arrhythmia. Patients with a history of percutaneous coronary interventions were questioned; according to which 92% of respondents reported that they felt more comfortable after the intervention followed by telemetric ECG-monitoring. Conclusion. Carrying out telemetric ECG-monitoring after EI on the CA improves the quality of observation after the procedure, promotes early discharge of patients, makes the intervention more comfortable and safe. The introduction of this technique into clinical practice will make it possible to more widely use the outpatient approach when carrying out EI, and to increase the turnover of specialized beds and the efficiency of the work of medical institutions.
- 24 October 2022
- Published by Consilium Medicum in Terapevticheskii arkhiv
- Vol. 94 (9) , 1062-1066
Open AccessRemote electrocardiogram telemonitoring after endovascular interventions on the coronary arteries
Aim. To evaluate the effectiveness of a new system for telemetric electrocardiogram (ECG) monitoring in patients after endovascular interventions (EI) on the coronary arteries (CA). Materials and methods. 168 patients with chronic ischemic heart disease who underwent EI on the CA on an outpatient basis, and during routine hospitalization, followed by telemetric ECG-monitoring after interventions were included. The monitoring was carried out using a three-channel telemetric recorder Astrocard HE3 (Russia), which provides continuous monitoring of 3-lead ECG for a long time. Results. The telemetry was successfully performed in all 168 (100%) patients. In 165 (98%) patients, the quality of the recording was regarded as good, in 3 (2%) as satisfactory. There were no cases of disconnection of the device, no interruptions in recording. During the observation period, no life-threatening arrhythmia revealed. When comparing the telemetry results in different groups of patients, there were no significant differences in the incidence of arrhythmia. Patients with a history of percutaneous coronary interventions were questioned; according to which 92% of respondents reported that they felt more comfortable after the intervention followed by telemetric ECG-monitoring. Conclusion. Carrying out telemetric ECG-monitoring after EI on the CA improves the quality of observation after the procedure, promotes early discharge of patients, makes the intervention more comfortable and safe. The introduction of this technique into clinical practice will make it possible to more widely use the outpatient approach when carrying out EI, and to increase the turnover of specialized beds and the efficiency of the work of medical institutions.