Jaimy Emerentiana Koopman
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Jaimy Emerentiana Koopman has a total of 77 co-authors. Here are the top co-authors by number of shared publications:
Caroline A. Hundepool
Department of Plastic, Reconstructive and Hand Surgery, Erasmus Medical Centre, Rotterdam, The Netherlands
7 shared publicationsJ. Michiel Zuidam
Department of Plastic, Reconstructive and Hand Surgery, Erasmus Medical Centre, Rotterdam, The Netherlands
4 shared publications- J. Michiel Zuidam
Department of Plastic, Reconstructive and Hand Surgery, Erasmus MC, Rotterdam, The Netherlands
4 shared publications Robbert M. Wouters
Department of Plastic, Reconstructive and Hand Surgery, Erasmus Medical Centre, Rotterdam, The Netherlands
4 shared publicationsRuud W. Selles
Department of Plastic, Reconstructive and Hand Surgery, Erasmus Medical Centre, Rotterdam, The Netherlands
4 shared publicationsJeroen M. Smit
Hand and Wrist Center, Xpert Clinics, the Netherlands
3 shared publications
Latest Publications
- Open Access
- 3 March 2026
- Published by MDPI AG in Journal of Personalized Medicine
- Vol. 16  (3) , 144
Flexor Tendon Repair Using a New Looped Six- and Eight-Strand Technique—A Biomechanical Analysis
Background/Objectives: Tendon injuries are a common cause of emergency department presentation and impose a substantial socioeconomic burden. Despite advances in surgical techniques, rupture rates after primary repair remain at 3.1–11.7%. Contemporary repairs typically combine at least four core strands with epitenon sutures to achieve sufficient tensile strength while limiting bulk. Increasing the number of core strands improves strength but may impair gliding and healing. Looped core sutures increase the effective strand number without additional knots or passes, potentially allowing omission of the epitenon suture and thus limiting repair complexity and bulk. The objective was to determine whether six- or eight-strand looped core suture techniques provide sufficient tensile strength to allow omission of an epitenon suture without excessive repair bulk, compared with a conventional four-strand Adelaide repair. Methods: One hundred and twenty human flexor digitorum profundus tendons were harvested from fresh-frozen anatomical specimens and allocated to six groups: Adelaide (four-strand) ± epitenon suture, six-strand ± epitenon suture, and eight-strand ± epitenon suture. Repairs were performed in zone II. The cross-sectional area (CSA) was measured before and after repair to quantify bulkiness. Tendons were tested to failure using axial tensile loading, and the failure mode was recorded. Results: The Adelaide with epitenon suture, six-strand with epitenon suture, and eight-strand with epitenon suture demonstrated significantly higher load to failure than the Adelaide without epitenon suture. The eight-strand without epitenon suture achieved a load to failure comparable to the Adelaide with epitenon suture, while also resulting in a smaller increase in CSA. The Adelaide with epitenon suture showed the greatest increase in CSA, while the six-strand without epitenon suture showed the smallest increase in CSA. Suture breakage was the predominant failure mode. Conclusions: An eight-strand looped core suture without epitenon suture provides comparable tensile strength to the conventional Adelaide repair with epitenon suture while minimizing repair bulk. The six-strand with epitenon suture demonstrated similar tensile strength to higher-strand techniques and may represent a mechanically adequate alternative with less tissue manipulation. These findings support a more individualized approach to flexor tendon repair, in which the choice of repair construct can be tailored to biomechanical demands and clinical context rather than applying a single uniform technique.
- 3 March 2026
- Published by MDPI AG in Journal of Personalized Medicine
- Vol. 16  (3) , 144
Open AccessFlexor Tendon Repair Using a New Looped Six- and Eight-Strand Technique—A Biomechanical Analysis
Background/Objectives: Tendon injuries are a common cause of emergency department presentation and impose a substantial socioeconomic burden. Despite advances in surgical techniques, rupture rates after primary repair remain at 3.1–11.7%. Contemporary repairs typically combine at least four core strands with epitenon sutures to achieve sufficient tensile strength while limiting bulk. Increasing the number of core strands improves strength but may impair gliding and healing. Looped core sutures increase the effective strand number without additional knots or passes, potentially allowing omission of the epitenon suture and thus limiting repair complexity and bulk. The objective was to determine whether six- or eight-strand looped core suture techniques provide sufficient tensile strength to allow omission of an epitenon suture without excessive repair bulk, compared with a conventional four-strand Adelaide repair. Methods: One hundred and twenty human flexor digitorum profundus tendons were harvested from fresh-frozen anatomical specimens and allocated to six groups: Adelaide (four-strand) ± epitenon suture, six-strand ± epitenon suture, and eight-strand ± epitenon suture. Repairs were performed in zone II. The cross-sectional area (CSA) was measured before and after repair to quantify bulkiness. Tendons were tested to failure using axial tensile loading, and the failure mode was recorded. Results: The Adelaide with epitenon suture, six-strand with epitenon suture, and eight-strand with epitenon suture demonstrated significantly higher load to failure than the Adelaide without epitenon suture. The eight-strand without epitenon suture achieved a load to failure comparable to the Adelaide with epitenon suture, while also resulting in a smaller increase in CSA. The Adelaide with epitenon suture showed the greatest increase in CSA, while the six-strand without epitenon suture showed the smallest increase in CSA. Suture breakage was the predominant failure mode. Conclusions: An eight-strand looped core suture without epitenon suture provides comparable tensile strength to the conventional Adelaide repair with epitenon suture while minimizing repair bulk. The six-strand with epitenon suture demonstrated similar tensile strength to higher-strand techniques and may represent a mechanically adequate alternative with less tissue manipulation. These findings support a more individualized approach to flexor tendon repair, in which the choice of repair construct can be tailored to biomechanical demands and clinical context rather than applying a single uniform technique.
- Open Access
- 28 November 2025
- Published by Elsevier in Journal of Plastic, Reconstructive & Aesthetic Surgery
- Vol. 113, 411-418
Patient-reported outcomes and complications of flexor tendon tenolysis following prior A1 pulley release: A cohort of 139 patients
- 28 November 2025
- Published by Elsevier in Journal of Plastic, Reconstructive & Aesthetic Surgery
- Vol. 113, 411-418
Open AccessPatient-reported outcomes and complications of flexor tendon tenolysis following prior A1 pulley release: A cohort of 139 patients
- Open Access
- 29 March 2025
- Published by Elsevier in Journal of Plastic, Reconstructive & Aesthetic Surgery
- Vol. 105, 369-382
Does short-term intraoperative electrical stimulation enhance nerve regeneration following peripheral nerve repair? A systematic review and meta-analysis
- 29 March 2025
- Published by Elsevier in Journal of Plastic, Reconstructive & Aesthetic Surgery
- Vol. 105, 369-382
Open AccessDoes short-term intraoperative electrical stimulation enhance nerve regeneration following peripheral nerve repair? A systematic review and meta-analysis
- Open Access
- 16 February 2024
- Published by SAGE Publications in Journal of Hand Surgery (European Volume)
- Vol. 49  (10) , 1226-1234
Incision techniques for trigger thumb release: a comparison of outcomes of four types of skin incision
Although trigger thumb release is commonly performed, there is no consensus on the optimal skin incision. This study aimed to compare outcomes of four incision techniques, including V-shaped, oblique, transverse and longitudinal incisions. Outcomes included the Michigan Hand Outcomes Questionnaire, satisfaction with the treatment and postoperative complications. The results of 875 patients who underwent trigger thumb release were assessed. All groups demonstrated improvement in self-reported hand function (range of 10–14 points), pain (25–27 points) and aesthetics (4–7 points) from baseline to 3 months postoperatively with no differences between incision techniques. Of the patients, 76% reported good or excellent satisfaction with the outcome of treatment. Satisfaction and complication rates of the different incision techniques were similar. These findings imply that there is no clear benefit of one type of incision over another for trigger thumb release, suggesting that surgeons may use the technique of their preference. Level of evidence: III
- 16 February 2024
- Published by SAGE Publications in Journal of Hand Surgery (European Volume)
- Vol. 49  (10) , 1226-1234
Open AccessIncision techniques for trigger thumb release: a comparison of outcomes of four types of skin incision
Although trigger thumb release is commonly performed, there is no consensus on the optimal skin incision. This study aimed to compare outcomes of four incision techniques, including V-shaped, oblique, transverse and longitudinal incisions. Outcomes included the Michigan Hand Outcomes Questionnaire, satisfaction with the treatment and postoperative complications. The results of 875 patients who underwent trigger thumb release were assessed. All groups demonstrated improvement in self-reported hand function (range of 10–14 points), pain (25–27 points) and aesthetics (4–7 points) from baseline to 3 months postoperatively with no differences between incision techniques. Of the patients, 76% reported good or excellent satisfaction with the outcome of treatment. Satisfaction and complication rates of the different incision techniques were similar. These findings imply that there is no clear benefit of one type of incision over another for trigger thumb release, suggesting that surgeons may use the technique of their preference. Level of evidence: III
- Open Access
- 13 February 2023
- Published by Springer Nature in Quality of Life Research
- Vol. 32  (6) , 1819-1830
Estimating meaningful thresholds for multi-item questionnaires using item response theory
Purpose: Meaningful thresholds are needed to interpret patient-reported outcome measure (PROM) results. This paper introduces a new method, based on item response theory (IRT), to estimate such thresholds. The performance of the method is examined in simulated datasets and two real datasets, and compared with other methods.Methods: The IRT method involves fitting an IRT model to the PROM items and an anchor item indicating the criterion state of interest. The difficulty parameter of the anchor item represents the meaningful threshold on the latent trait. The latent threshold is then linked to the corresponding expected PROM score. We simulated 4500 item response datasets to a 10-item PROM, and an anchor item. The datasets varied with respect to the mean and standard deviation of the latent trait, and the reliability of the anchor item. The real datasets consisted of a depression scale with a clinical depression diagnosis as anchor variable and a pain scale with a patient acceptable symptom state (PASS) question as anchor variable.Results: The new IRT method recovered the true thresholds accurately across the simulated datasets. The other methods, except one, produced biased threshold estimates if the state prevalence was smaller or greater than 0.5. The adjusted predictive modeling method matched the new IRT method (also in the real datasets) but showed some residual bias if the prevalence was smaller than 0.3 or greater than 0.7.Conclusions: The new IRT method perfectly recovers meaningful (interpretational) thresholds for multi-item questionnaires, provided that the data satisfy the assumptions for IRT analysis.
- 13 February 2023
- Published by Springer Nature in Quality of Life Research
- Vol. 32  (6) , 1819-1830
Open AccessEstimating meaningful thresholds for multi-item questionnaires using item response theory
Purpose: Meaningful thresholds are needed to interpret patient-reported outcome measure (PROM) results. This paper introduces a new method, based on item response theory (IRT), to estimate such thresholds. The performance of the method is examined in simulated datasets and two real datasets, and compared with other methods.Methods: The IRT method involves fitting an IRT model to the PROM items and an anchor item indicating the criterion state of interest. The difficulty parameter of the anchor item represents the meaningful threshold on the latent trait. The latent threshold is then linked to the corresponding expected PROM score. We simulated 4500 item response datasets to a 10-item PROM, and an anchor item. The datasets varied with respect to the mean and standard deviation of the latent trait, and the reliability of the anchor item. The real datasets consisted of a depression scale with a clinical depression diagnosis as anchor variable and a pain scale with a patient acceptable symptom state (PASS) question as anchor variable.Results: The new IRT method recovered the true thresholds accurately across the simulated datasets. The other methods, except one, produced biased threshold estimates if the state prevalence was smaller or greater than 0.5. The adjusted predictive modeling method matched the new IRT method (also in the real datasets) but showed some residual bias if the prevalence was smaller than 0.3 or greater than 0.7.Conclusions: The new IRT method perfectly recovers meaningful (interpretational) thresholds for multi-item questionnaires, provided that the data satisfy the assumptions for IRT analysis.
- Open Access
- 1 January 2023
- Published by Elsevier in Journal of Hand Therapy
- Vol. 36  (1) , 139-147
Determining the Minimally Important Change of the Michigan Hand outcomes Questionnaire in patients undergoing trigger finger release
- 1 January 2023
- Published by Elsevier in Journal of Hand Therapy
- Vol. 36  (1) , 139-147
Open AccessDetermining the Minimally Important Change of the Michigan Hand outcomes Questionnaire in patients undergoing trigger finger release
- Open Access
- 17 June 2022
- Published by Elsevier in The Journal of Hand Surgery
- Vol. 47  (9) , 823-833
Prevalence and Risk Factors for Postoperative Complications Following Open A1 Pulley Release for a Trigger Finger or Thumb
- 17 June 2022
- Published by Elsevier in The Journal of Hand Surgery
- Vol. 47  (9) , 823-833
Open AccessPrevalence and Risk Factors for Postoperative Complications Following Open A1 Pulley Release for a Trigger Finger or Thumb
- Open Access
- 10 March 2022
- Published by SAGE Publications in Journal of Hand Surgery (European Volume)
- Vol. 47  (7) , 734-741
Factors associated with self-reported pain and hand function following surgical A1 pulley release
Surgical A1 pulley release can considerably reduce pain and improve hand function, but individual outcomes are highly variable. This study aimed to identify factors contributing to self-reported pain and hand function 3 months postoperatively. We included 2681 patients who had received surgical treatment for a trigger finger or thumb and who completed the Michigan Hand outcomes Questionnaire (MHQ). Hierarchical linear regression models were used to investigate patient and clinical characteristics associated with postoperative pain and hand function. For both pain and hand function, the most influential factors associated with worse outcomes were worse MHQ scores at baseline (β 0.38 and 0.33, respectively) and ≥3 preoperative steroid injections (β –0.36 and –0.35). These factors indicated that patients with severe preoperative symptoms represent a group with a more advanced disease that is more difficult to treat. These findings can assist clinicians in patient counselling, expectation management and decision-making about the timing of the intervention. Level of evidence: II
- 10 March 2022
- Published by SAGE Publications in Journal of Hand Surgery (European Volume)
- Vol. 47  (7) , 734-741
Open AccessFactors associated with self-reported pain and hand function following surgical A1 pulley release
Surgical A1 pulley release can considerably reduce pain and improve hand function, but individual outcomes are highly variable. This study aimed to identify factors contributing to self-reported pain and hand function 3 months postoperatively. We included 2681 patients who had received surgical treatment for a trigger finger or thumb and who completed the Michigan Hand outcomes Questionnaire (MHQ). Hierarchical linear regression models were used to investigate patient and clinical characteristics associated with postoperative pain and hand function. For both pain and hand function, the most influential factors associated with worse outcomes were worse MHQ scores at baseline (β 0.38 and 0.33, respectively) and ≥3 preoperative steroid injections (β –0.36 and –0.35). These factors indicated that patients with severe preoperative symptoms represent a group with a more advanced disease that is more difficult to treat. These findings can assist clinicians in patient counselling, expectation management and decision-making about the timing of the intervention. Level of evidence: II
- Open Access
- 19 January 2022
- Published by Elsevier in Journal of Plastic, Reconstructive & Aesthetic Surgery
- Vol. 75  (3) , 1018-1033
A systematic review and meta-analysis on the use of fibrin glue in peripheral nerve repair: Can we just glue it?
- 19 January 2022
- Published by Elsevier in Journal of Plastic, Reconstructive & Aesthetic Surgery
- Vol. 75  (3) , 1018-1033
Open AccessA systematic review and meta-analysis on the use of fibrin glue in peripheral nerve repair: Can we just glue it?
- 27 December 2021
- Published by Wolters Kluwer Health in Clinical Orthopaedics and Related Research
- Vol. 480  (6) , 1152-1166
What Are the Minimally Important Changes of Four Commonly Used Patient-reported Outcome Measures for 36 Hand and Wrist Condition-Treatment Combinations?
Background: Patient-reported outcome measures (PROMs) are frequently used to assess treatment outcomes for hand and wrist conditions. To adequately interpret these outcomes, it is important to determine whether a statistically significant change is also clinically relevant. For this purpose, the minimally important change (MIC) was developed, representing the minimal within-person change in outcome that patients perceive as a beneficial treatment effect. Prior studies demonstrated substantial differences in MICs between condition-treatment combinations, suggesting that MICs are context-specific and cannot be reliably generalized. Hence, a study providing MICs for a wide diversity of condition-treatment combinations for hand and wrist conditions will contribute to more accurate treatment evaluations. Questions/purposes: (1) What are the MICs of the most frequently used PROMs for common condition-treatment combinations of hand and wrist conditions? (2) Do MICs vary based on the invasiveness of the treatment (nonsurgical treatment or surgical treatment)? Methods: This study is based on data from a longitudinally maintained database of patients with hand and wrist conditions treated in one of 26 outpatient clinics in the Netherlands between November 2013 and November 2020. Patients were invited to complete several validated PROMs before treatment and at final follow-up. All patients were invited to complete the VAS for pain and hand function. Depending on the condition, patients were also invited to complete the Michigan Hand outcomes Questionnaire (MHQ) (finger and thumb conditions), the Patient-rated Wrist/Hand Evaluation (PRWHE) (wrist conditions), or the Boston Carpal Tunnel Questionnaire (BCTQ) (nerve conditions). Additionally, patients completed the validated Satisfaction with Treatment Result Questionnaire at final follow-up. Final follow-up timepoints were 3 months for nonsurgical and minor surgical treatment (including trigger finger release) and 12 months for major surgical treatment (such as trapeziectomy). Our database included 55,651 patients, of whom we excluded 1528 who only required diagnostic management, 25,099 patients who did not complete the Satisfaction with Treatment Result Questionnaire, 3509 patients with missing data in the PROM of interest at baseline or follow-up, and 1766 patients who were part of condition-treatment combinations with less than 100 patients. The final sample represented 43% (23,749) of all patients and consisted of 36 condition-treatment combinations. In this final sample, 26% (6179) of patients were managed nonsurgically and 74% (17,570) were managed surgically. Patients had a mean ± SD age of 55 ± 14 years, and 66% (15,593) of patients were women. To estimate the MIC, we used two anchor-based methods (the anchor mean change and the MIC predict method), which were triangulated afterward to obtain a single MIC. Applying this method, we calculated the MIC for 36 condition-treatment combinations, comprising 22 different conditions, and calculated the MIC for combined nonsurgical and surgical treatment groups. To examine whether the MIC differs between nonsurgical and surgical treatments, we performed a Wilcoxon signed rank test to compare the MICs of all PROM scores between nonsurgical and surgical treatment. Results: We found a large variation in triangulated MICs between the condition-treatment combinations. For example, for nonsurgical treatment of hand OA, the MICs of VAS pain during load clustered around 10 (interquartile range 8 to 11), for wrist osteotomy/carpectomy it was around 25 (IQR 24 to 27), and for nerve decompression it was 21. Additionally, the MICs of the MHQ total score ranged from 4 (nonsurgical treatment of CMC1 OA) to 15 (trapeziectomy with LRTI and bone tunnel), for the PRWHE total score it ranged from 2 (nonsurgical treatment of STT OA) to 29 (release of first extensor compartment), and for the BCTQ Symptom Severity Scale it ranged from 0.44 (nonsurgical treatment of carpal tunnel syndrome) to 0.87 (carpal tunnel release). An overview of all MIC values is available in a freely available online application at: https://analyse.equipezorgbedrijven.nl/shiny/mic-per-treatment/. In the combined treatment groups, the triangulated MIC values were lower for nonsurgical treatment than for surgical treatment (p < 0.001). The MICs for nonsurgical treatment can be approximated to be one-ninth (IQR 0.08 to 0.13) of the scale (approximately 11 on a 100-point instrument), and surgical treatment had MICs that were approximately one-fifth (IQR 0.14 to 0.24) of the scale (approximately 19 on a 100-point instrument). Conclusion: MICs vary between condition-treatment combinations and differ depending on the invasiveness of the intervention. Patients receiving a more invasive treatment have higher treatment expectations, may experience more discomfort from their treatment, or may feel that the investment of undergoing a more invasive treatment should yield greater improvement, leading to a different perception of what constitutes a beneficial treatment effect. Clinical Relevance: Our findings indicate that the MIC is context-specific and may be misleading if applied inappropriately. Implementation of these condition-specific and treatment-specific MICs in clinical research allows for a better study design and to achieve more accurate treatment evaluations. Consequently, this could aid clinicians in better informing patients about the expected treatment results and facilitate shared decision-making in clinical practice. Future studies may focus on adaptive techniques to achieve individualized MICs, which may ultimately aid clinicians in selecting the optimal treatment for individual patients.
- 27 December 2021
- Published by Wolters Kluwer Health in Clinical Orthopaedics and Related Research
- Vol. 480  (6) , 1152-1166
What Are the Minimally Important Changes of Four Commonly Used Patient-reported Outcome Measures for 36 Hand and Wrist Condition-Treatment Combinations?
Background: Patient-reported outcome measures (PROMs) are frequently used to assess treatment outcomes for hand and wrist conditions. To adequately interpret these outcomes, it is important to determine whether a statistically significant change is also clinically relevant. For this purpose, the minimally important change (MIC) was developed, representing the minimal within-person change in outcome that patients perceive as a beneficial treatment effect. Prior studies demonstrated substantial differences in MICs between condition-treatment combinations, suggesting that MICs are context-specific and cannot be reliably generalized. Hence, a study providing MICs for a wide diversity of condition-treatment combinations for hand and wrist conditions will contribute to more accurate treatment evaluations. Questions/purposes: (1) What are the MICs of the most frequently used PROMs for common condition-treatment combinations of hand and wrist conditions? (2) Do MICs vary based on the invasiveness of the treatment (nonsurgical treatment or surgical treatment)? Methods: This study is based on data from a longitudinally maintained database of patients with hand and wrist conditions treated in one of 26 outpatient clinics in the Netherlands between November 2013 and November 2020. Patients were invited to complete several validated PROMs before treatment and at final follow-up. All patients were invited to complete the VAS for pain and hand function. Depending on the condition, patients were also invited to complete the Michigan Hand outcomes Questionnaire (MHQ) (finger and thumb conditions), the Patient-rated Wrist/Hand Evaluation (PRWHE) (wrist conditions), or the Boston Carpal Tunnel Questionnaire (BCTQ) (nerve conditions). Additionally, patients completed the validated Satisfaction with Treatment Result Questionnaire at final follow-up. Final follow-up timepoints were 3 months for nonsurgical and minor surgical treatment (including trigger finger release) and 12 months for major surgical treatment (such as trapeziectomy). Our database included 55,651 patients, of whom we excluded 1528 who only required diagnostic management, 25,099 patients who did not complete the Satisfaction with Treatment Result Questionnaire, 3509 patients with missing data in the PROM of interest at baseline or follow-up, and 1766 patients who were part of condition-treatment combinations with less than 100 patients. The final sample represented 43% (23,749) of all patients and consisted of 36 condition-treatment combinations. In this final sample, 26% (6179) of patients were managed nonsurgically and 74% (17,570) were managed surgically. Patients had a mean ± SD age of 55 ± 14 years, and 66% (15,593) of patients were women. To estimate the MIC, we used two anchor-based methods (the anchor mean change and the MIC predict method), which were triangulated afterward to obtain a single MIC. Applying this method, we calculated the MIC for 36 condition-treatment combinations, comprising 22 different conditions, and calculated the MIC for combined nonsurgical and surgical treatment groups. To examine whether the MIC differs between nonsurgical and surgical treatments, we performed a Wilcoxon signed rank test to compare the MICs of all PROM scores between nonsurgical and surgical treatment. Results: We found a large variation in triangulated MICs between the condition-treatment combinations. For example, for nonsurgical treatment of hand OA, the MICs of VAS pain during load clustered around 10 (interquartile range 8 to 11), for wrist osteotomy/carpectomy it was around 25 (IQR 24 to 27), and for nerve decompression it was 21. Additionally, the MICs of the MHQ total score ranged from 4 (nonsurgical treatment of CMC1 OA) to 15 (trapeziectomy with LRTI and bone tunnel), for the PRWHE total score it ranged from 2 (nonsurgical treatment of STT OA) to 29 (release of first extensor compartment), and for the BCTQ Symptom Severity Scale it ranged from 0.44 (nonsurgical treatment of carpal tunnel syndrome) to 0.87 (carpal tunnel release). An overview of all MIC values is available in a freely available online application at: https://analyse.equipezorgbedrijven.nl/shiny/mic-per-treatment/. In the combined treatment groups, the triangulated MIC values were lower for nonsurgical treatment than for surgical treatment (p < 0.001). The MICs for nonsurgical treatment can be approximated to be one-ninth (IQR 0.08 to 0.13) of the scale (approximately 11 on a 100-point instrument), and surgical treatment had MICs that were approximately one-fifth (IQR 0.14 to 0.24) of the scale (approximately 19 on a 100-point instrument). Conclusion: MICs vary between condition-treatment combinations and differ depending on the invasiveness of the intervention. Patients receiving a more invasive treatment have higher treatment expectations, may experience more discomfort from their treatment, or may feel that the investment of undergoing a more invasive treatment should yield greater improvement, leading to a different perception of what constitutes a beneficial treatment effect. Clinical Relevance: Our findings indicate that the MIC is context-specific and may be misleading if applied inappropriately. Implementation of these condition-specific and treatment-specific MICs in clinical research allows for a better study design and to achieve more accurate treatment evaluations. Consequently, this could aid clinicians in better informing patients about the expected treatment results and facilitate shared decision-making in clinical practice. Future studies may focus on adaptive techniques to achieve individualized MICs, which may ultimately aid clinicians in selecting the optimal treatment for individual patients.