Jianfeng Ye
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Jianfeng Ye has a total of 12 co-authors. Here are the top co-authors by number of shared publications:
Haoyun Wei
Tsinghua University
4 shared publications- Yan Li
State Key Laboratory of Precision Measurement Technology and Instruments, Department of Precision Instrument, Tsinghua University, Beijing 100084, China
4 shared publications - Mingqiang Zou
Chinese Academy of Inspection & Quarantine
3 shared publications Boyi Li
Chinese Academy of Inspection & Quarantine
2 shared publicationsMinjian Lu
Tsinghua University
2 shared publicationsXiaohua Qi
Chinese Academy of Inspection & Quarantine
2 shared publications
Latest Publications
- 5 August 2021
- Published by Optica Publishing Group in Applied Optics
- Vol. 60 (23) , 6918-6927
Dual-wavelength excitation combined Raman spectroscopy for detection of highly fluorescent samples
As fluorescence is the major limitation in Raman scattering, near-infrared excitation wavelength ( > 780 n m ) is preferred for fluorescence suppression in Raman spectroscopy. To reduce the risk of fluorescence interference, we developed a dual-wavelength excitation combined Raman spectroscopy (DWECRS) system at 785 and 830 nm. By a common optical path, each laser beam was focused on the same region of the sample by a single objective lens, and the dual-wavelength excitation Raman spectra were detected by a single CCD detector; in addition, 785 and 830 nm excitation Raman spectra can be directly constructed as combined Raman spectrum in the DWECRS system. The results of pure peanut oil and glycerol indicate that the combined Raman spectrum cannot only reduce fluorescence interference but also keep a high signal-to-noise ratio in the high-wavenumber region. The results of dye-ethanol solutions with different concentrations show that the handheld DWECRS system can be used as a smart method to dodge strong fluorescence. Furthermore, we developed a peak intensity ratio method with the DWECRS system to distinguish different types of edible oils. The peak intensity ratio distribution chart of edible oils showed each oil normalized center was relatively independent and nonoverlapped, which can be used as the basis of edible oil classification analysis. In the future, the DWECRS system has potential to be used as a tool for more complex applications.
- 5 August 2021
- Published by Optica Publishing Group in Applied Optics
- Vol. 60 (23) , 6918-6927
Dual-wavelength excitation combined Raman spectroscopy for detection of highly fluorescent samples
As fluorescence is the major limitation in Raman scattering, near-infrared excitation wavelength ( > 780 n m ) is preferred for fluorescence suppression in Raman spectroscopy. To reduce the risk of fluorescence interference, we developed a dual-wavelength excitation combined Raman spectroscopy (DWECRS) system at 785 and 830 nm. By a common optical path, each laser beam was focused on the same region of the sample by a single objective lens, and the dual-wavelength excitation Raman spectra were detected by a single CCD detector; in addition, 785 and 830 nm excitation Raman spectra can be directly constructed as combined Raman spectrum in the DWECRS system. The results of pure peanut oil and glycerol indicate that the combined Raman spectrum cannot only reduce fluorescence interference but also keep a high signal-to-noise ratio in the high-wavenumber region. The results of dye-ethanol solutions with different concentrations show that the handheld DWECRS system can be used as a smart method to dodge strong fluorescence. Furthermore, we developed a peak intensity ratio method with the DWECRS system to distinguish different types of edible oils. The peak intensity ratio distribution chart of edible oils showed each oil normalized center was relatively independent and nonoverlapped, which can be used as the basis of edible oil classification analysis. In the future, the DWECRS system has potential to be used as a tool for more complex applications.
- 20 April 2021
- Published by Optica Publishing Group in Applied Optics
- Vol. 60 (12) , 3540-3548
Dual-wavelength wide area illumination Raman difference spectroscopy for remote detection of chemicals
Remote Raman instruments have become powerful analytical tools in some special environments. However, ambient daylight is the main limitation in the data acquisition process. To suppress daylight background interference and obtain a high signal-to-background ratio (SBR), we develop a dual-wavelength wide area illumination Raman difference spectroscopy (WAIRDS) system for daytime remote detection. In the WAIRDS system, a wide area illumination scheme and shifted-excitation Raman difference spectroscopy method are used to improve the reliability of collected Raman spectra. Measurements of polystyrene indicate that the WAIRDS system can be operated to obtain background-free Raman spectra under different levels of daylight background interference. The remote results show that the improvement in SBR is about three- to fivefold, and the system can work at distances of up to 9.2 m on a sunny afternoon. Moreover, to be close to the actual detection, the system is used for mineral and explosive raw material detection during daytime measurement. Measurements show that the WAIRDS system will be a useful tool for many remote applications in the future.
- 20 April 2021
- Published by Optica Publishing Group in Applied Optics
- Vol. 60 (12) , 3540-3548
Dual-wavelength wide area illumination Raman difference spectroscopy for remote detection of chemicals
Remote Raman instruments have become powerful analytical tools in some special environments. However, ambient daylight is the main limitation in the data acquisition process. To suppress daylight background interference and obtain a high signal-to-background ratio (SBR), we develop a dual-wavelength wide area illumination Raman difference spectroscopy (WAIRDS) system for daytime remote detection. In the WAIRDS system, a wide area illumination scheme and shifted-excitation Raman difference spectroscopy method are used to improve the reliability of collected Raman spectra. Measurements of polystyrene indicate that the WAIRDS system can be operated to obtain background-free Raman spectra under different levels of daylight background interference. The remote results show that the improvement in SBR is about three- to fivefold, and the system can work at distances of up to 9.2 m on a sunny afternoon. Moreover, to be close to the actual detection, the system is used for mineral and explosive raw material detection during daytime measurement. Measurements show that the WAIRDS system will be a useful tool for many remote applications in the future.
- 8 March 2021
- Published by Optica Publishing Group in Applied Optics
- Vol. 60 (8) , 2354-2361
Surface-enhanced shifted excitation Raman difference spectroscopy for trace detection of fentanyl in beverages
In recognition of the misuse risks of fentanyl, there is an urgent need to develop a useful and rapid analytical method to detect and monitor the opioid drug. The surface-enhanced shifted excitation Raman difference spectroscopy (SE-SERDS) method has been demonstrated to suppress background interference and enhance Raman signals. In this study, the SE-SERDS method was used for trace detection of fentanyl in beverages. To prepare the simulated illegal drug–beverages, fentanyls were dissolved into distilled water or Mizone as a series of test samples. Based on our previous work, the surface-enhanced Raman spectroscopy detection was performed on the beverages containing fentanyl by the prepared AgNPs and the SE-SERDS spectra of test samples were collected by the dual-wavelength rapid excitation Raman difference spectroscopy system. In addition, the quantitative relationship between fentanyl concentrations and the Raman peaks was constructed by the Langmuir equation. The experimental results show that the limits of quantitation for fentanyl in distilled water and Mizone were 10 ng/mL and 200 ng/mL, respectively; the correlation coefficients for the nonlinear regression were as high as 0.9802 and 0.9794, respectively; and the relative standard deviation was less than 15%. Hence, the SE-SERDS method will be a promising method for the trace analyses of food safety and forensics.
- 8 March 2021
- Published by Optica Publishing Group in Applied Optics
- Vol. 60 (8) , 2354-2361
Surface-enhanced shifted excitation Raman difference spectroscopy for trace detection of fentanyl in beverages
In recognition of the misuse risks of fentanyl, there is an urgent need to develop a useful and rapid analytical method to detect and monitor the opioid drug. The surface-enhanced shifted excitation Raman difference spectroscopy (SE-SERDS) method has been demonstrated to suppress background interference and enhance Raman signals. In this study, the SE-SERDS method was used for trace detection of fentanyl in beverages. To prepare the simulated illegal drug–beverages, fentanyls were dissolved into distilled water or Mizone as a series of test samples. Based on our previous work, the surface-enhanced Raman spectroscopy detection was performed on the beverages containing fentanyl by the prepared AgNPs and the SE-SERDS spectra of test samples were collected by the dual-wavelength rapid excitation Raman difference spectroscopy system. In addition, the quantitative relationship between fentanyl concentrations and the Raman peaks was constructed by the Langmuir equation. The experimental results show that the limits of quantitation for fentanyl in distilled water and Mizone were 10 ng/mL and 200 ng/mL, respectively; the correlation coefficients for the nonlinear regression were as high as 0.9802 and 0.9794, respectively; and the relative standard deviation was less than 15%. Hence, the SE-SERDS method will be a promising method for the trace analyses of food safety and forensics.
- 30 November 2020
- Published by Optica Publishing Group in Applied Optics
- Vol. 59 (34) , 10933-10943
Baseline correction method based on improved asymmetrically reweighted penalized least squares for the Raman spectrum
We present a baseline correction method based on improved asymmetrically reweighted penalized least squares ( IarPLS ) for the Raman spectrum. This method utilizes a new S-type function to reduce the risk of baseline overestimation and speed up the reweighting process. Simulated spectra with different levels of noise and measured spectra with strong fluorescence background from different samples are used to validate the performance of the proposed algorithm. Considering the drawbacks of the weighting rules for the asymmetrically reweighted penalized least squares ( arPLS ) method, we adapt an inverse square root unit ( ISRU ) function, which performs well in baseline correction. Compared with previous penalized least squares methods, such as asymmetric least squares, adaptive iteratively reweighted penalized least squares, and arPLS , experiments with the simulated Raman spectra have confirmed that the proposed method yields better outcomes. Experiments with the measured Raman spectra show that the IarPLS method can improve real Raman spectra within 20 ms. The results show that the proposed method can be successfully applied to the practical Raman spectrum as a strong basis for quantitative analysis.
- 30 November 2020
- Published by Optica Publishing Group in Applied Optics
- Vol. 59 (34) , 10933-10943
Baseline correction method based on improved asymmetrically reweighted penalized least squares for the Raman spectrum
We present a baseline correction method based on improved asymmetrically reweighted penalized least squares ( IarPLS ) for the Raman spectrum. This method utilizes a new S-type function to reduce the risk of baseline overestimation and speed up the reweighting process. Simulated spectra with different levels of noise and measured spectra with strong fluorescence background from different samples are used to validate the performance of the proposed algorithm. Considering the drawbacks of the weighting rules for the asymmetrically reweighted penalized least squares ( arPLS ) method, we adapt an inverse square root unit ( ISRU ) function, which performs well in baseline correction. Compared with previous penalized least squares methods, such as asymmetric least squares, adaptive iteratively reweighted penalized least squares, and arPLS , experiments with the simulated Raman spectra have confirmed that the proposed method yields better outcomes. Experiments with the measured Raman spectra show that the IarPLS method can improve real Raman spectra within 20 ms. The results show that the proposed method can be successfully applied to the practical Raman spectrum as a strong basis for quantitative analysis.